WARNING
Newly produced drivers work in the RFIO² data protocol mode. These drivers are
loaded in the actuators in a different way than before. Among other things, it
eliminates the risk of inadvertently loading another randomly occurring
controller within range.
Drivers can still be switched to so-called compatibility mode, and loaded in a
simpler (older way). The mode in which the controllers are working is changed
and indicated after 8-second pressing of the ‘Prog’ button.
The LED diode under the pushbutton is on when the button is kept pressed;
after 8 seconds it indicates the chosen mode by different flashing intervals.
The mode changes to the inverse mode after each pressing of the button.
RFIO² mode
= Double flash (flash, flash, gap, flash, flash)
Compatibility mode
= Flash fast (flash, flash, flash, flash, flash)
Update the controller actuators in RFIO² mode
If the controller is used in RFIO ² mode, then to update the controller
actuators, it is necessary to switch not only the actuator to the update mode
(according to the instructions for the actuator), but also the controller in
the following way: Press the programming button on the controller, converter
for more than 1 second (it is indicated by short extinction of the LED) and
release it. The LED diode under the button starts flashing in second intervals.
Leave the LED flashing on the (controller, converter). Then activate the
programming mode on the actuator by pressing the programming button for more
than 1 second. The actuator is also put into the programming mode. The desired
function can be selected by the respective number of pressing of the control
pushbuttons or inputs (of the converter). The programming modes on the
controller and actuator can be closed by pressing the programming button for
less than 1 second. The LEDs stop flashing.
Use a suitable tool (paper clip, screwdriver) to push on the control pin. The
batteries are raised and the programming button is release
After removing the control flaps, the programming button is accessible.
The programming button is operated with a suitable thin tool.
Characteristics
-
The dimmed socket is used to control light sources that are connected by power cord – especially lamps:
R – classic lamps.
L – halogen lamps with wound transformer.
C – halogen lamps with electronic transformer.
ESL – dimmable energy-efficient fluorescent lamps.
LED – LED light sources (230V). -
They can be combined with detectors, controllers, intel’s RF Control or system components.
-
Thanks to the socket design, installation is simple by direct insertion into the existing socket.
-
Output load 200W.
-
7 light functions – smooth starting up or running out with time setting 2 sec to 30 min + additional function SWITCH OFF
-
When switched off, the set level is stored in the memory, and when switched back on, it returns to the most recently set value.
-
Thanks to setting the min. brightness by potentiometer, you will eliminate flashing of the LED and ESL light sources.
-
The universal dimmer may be controlled by up to 32 channels (1 channel represents 1 button on the controller).
-
The programming button on the socket is also used for manual control of the output.
-
Memory status can be pre-set in the event of a power failure.
-
Range up to 160 m (in open space), if the signal is insufficient between the controller and unit, use the signal repeater RFRP-20N or protocol component RFIO ² that support this feature.
-
Communication frequency with bidirectional protocol intel’s RF Control ² (RFIO ² ).
-
You will find more on light sources and dimming options at www.elkoep.com/solutions.
-
Produced in 3 designs of sockets and plugs: French, Schuko, British
Assembly
Radio frequency signal penetration through various construction materials
For more information, see “Installation manual intel’s RF Control”: http://www.elkoep.com/catalogs-and-brochures
Indication, manual control
-
PROG button
-
LED indication
• Green – input indication
• Red – output ON -
Setting the load type
-
Set the minimum brightness
-
Green LED – stays lit upon connecting the supply voltage.
-
Red LED STATUS – indication of a closed contact.
Indicators of memory function:
On – LED blinks x 3.
Off – The LED lights up once for a long time. -
Manual control is performed by pressing the PROG button for less than 0.5s.
-
Programming is performed by pressing the PROG button for more than 1s.
In the programming and operating mode, the LED on the component lights up at the same time each time the button is pressed – this indicates the incoming command.
Set the minimum brightness – min :
– Minimum brightness setting turned on when we perform load by turning the
potentiometer min. brightness to the desired value.
– Min. brightness is automatically stored after ceca. 3 seconds since the last
potentiometer position change. Setting min. brightness by potentiometer on the
front side of device eliminates flashing of various types of light sources.
Setting the load type – LOAD:
– Setting the type of load is performed with disconnected load by turning the
light source selector to the desired position.
For the ESL load, when the lamp is switched off , a short press increases the
brightness to the maximum level (when the energy saver “lights up“) and then
drops to the preset level.
Type of source | Symbol | Description |
---|
R
resistive| | ordinary light bulb, halogen lamp
L
inductive| | coiled transformer for low-voltage halogen lamps
c
capacitive| | electronic transformer for low-voltage halogen lamps
LED| | LED lamps and LED light sources, 230 V
ESL| | dimmable energy-saving fluorescent tubes
The device can be combined with all system components, controls and devices of
intel’s RF Control and intel’s RF Control ².
The detector can be assigned an intel’s RF Control ² (RFIO ² )
communication protocol.
Functions and programming with RF transmitters
Light scene function 1
Description of light scene 1
a) By pressing the programmed button for less than 0.5s, the light
illuminates; it goes out by pressing again.
b) By pressing the programmed button for more than 0.5s, fluid brightness
regulation will occur. After releasing the button, the brightness level is
saved in the memory, and pressing the button shortly later will switch the
light on /off to this intensity.
c) It is possible to readjust the change in intensity at any time by a long
press of the programmed button. The socket remembers the adjusted value even
after disconnecting from the power supply.
Programming
Press of programming button on socket RFDSC-71N for 1 second will activate socket RFDSC-71N into programming mode. LED is flashing in 1s interval.
A press of your selected button on the RF transmitter assigns the function light scene 1.
Press of programming button on socket RFDSC-71N shorter then 1 second will
finish programming mode. The LED lights up according to the preset memory
function.
Light scene function 2
Description of light scene 2
a) By pressing the programmed button for less than 3s, the light illuminates;
it goes out by pressing again.
b) In order to limit undesirable control of brightness, fluid brightness
control occurs only by pressing a programmed button for over 3s. After
releasing the button, the brightness level is saved in the memory, and
pressing the button shortly later will switch the light on / off to this
intensity.
c) It is possible to readjust the change in intensity at any time by pressing
the programmed button for over 3s.
The socket remembers the adjusted value even after disconnecting from the
power supply.
Programming
Press of programming button on socket RFDSC-71N for 1 second will activate socket RFDSC-71N into programming mode. LED is flashing in 1s interval.
Two presses of your selected button on the RF transmitter assigns the function light scene 2 (must be a lapse of 1s between individual presses).
Press of programming button on socket RFDSC-71N shorter then 1 second will
finish programming mode. The LED lights up according to the preset memory
function.
Light scene function 3
Description of light scene 3
a) By pressing the programmed button for less than 0.5s, the light fluidly
illuminates for a period of 3s (at 100% brightness). By pressing the button
shortly again, the light will continuously switch off for 3 seconds.
b) By pressing the programmed button for more than 0.5s, fluid brightness
regulation will occur. After releasing the button, the brightness level is
saved in the memory, and pressing the button shortly later will switch the
light on /off to this intensity.
c) It is possible to readjust the change in intensity at any time by a long
press of the programmed button.
The socket remembers the adjusted value even after disconnecting from the
power supply.
Programming
Press of programming button on socket RFDSC-71N for 1 second will activate socket RFDSC-71N into programming mode. LED is flashing in 1s interval.
Three presses of your selected button on the RF transmitter assigns the function light scene 3 (must be a lapse of 1s between individual presses).
Press of programming button on socket RFDSC-71N shorter then 1 second will
finish programming mode. The LED lights up according to the preset memory
function.
Light scene function 4
Description of light scene 4
a) By pressing the programmed button for less than 0.5s, the light
illuminates. By pressing the button shortly again, the light will continuously
switch off for 3 seconds (at 100% brightness).
b) By pressing the programmed button for more than 0.5s, fluid brightness
regulation will occur. After releasing the button, the brightness level is
saved in the memory, and pressing the button shortly later will switch the
light on /off to this intensity.
c) It is possible to readjust the change in intensity at any time by a long
press of the programmed button.
The socket remembers the adjusted value even after disconnecting from the
power supply.
Programming
Press of programming button on socket RFDSC-71N for 1 second will activate socket RFDSC-71N into programming mode. LED is flashing in 1s interval.
Four presses of your selected button on the RF transmitter assigns the function light scene 4 (must be a lapse of 1s between individual presses).
Press of programming button on socket RFDSC-71N shorter then 1 second will finish programming mode. The LED lights up according to the preset memory function.
After the desired time has elapsed, the timing mode ends by pressing the button on the RF transmitter, to which the sunrise function is assigned. This stores the set time interval into the socket memory.
Press of programming button on socket RFDSC-71N shorter then 1 second will finish programming mode. The LED lights up according to the preset memory function.
Function sunset
Description of sunset function
After pressing the programmed button, the light begins to dim in the
programmed time interval in a range of 2 seconds to 30 minutes.
Made in Czech Republic
ELKO EP Germany GmbH | Minoritenstr. 7 | 50667 Köln
Deutschland | E-mail: elko@elkoep.de | Tel: +49 (0)
221 222 837 80
www.elkoep.com /
www.elkoep.de / www.elkoep.at
References
- ELKO EP - Hersteller von elektronischen Geräten • ELKO EP Germany
- Catalogs and brochures • ELKO EP
- ELKO EP - Hersteller von elektronischen Geräten • ELKO EP Germany
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>