Model: 72134-66 Product Name: Fixture Installation Kit Manufacturer: [Manufacturer Name]
Features:
- Easy installation process – Sturdy mounting plate for secure fixture placement
- Support cable provided for weight distribution during wiring
- Compatibility with candelabra base bulbs up to 60 watts or CFL/LED equivalent – Glass panels for an elegant look
- Ground wire connection for safety
Package Contents
- Mounting plate (1)
- Mounting screws (2)
- Ground screw (1)
- Glass panels (4)
- Candle covers (4)
- Frame tabs (4)
- Candelabra base bulbs (not included)
Product Usage Instructions
Preparing for Installation:
- Shut off power at the fuse box or circuit breaker box.
- Remove the old fixture and its mounting hardware.
- Unpack the new fixture and lay out all the parts.
- Separate the mounting plate from the back plate by removing the screws and rubber washers.
- Position the mounting plate on the wall and mark the location of the four drywall anchors.
- Pre-drill holes for the drywall anchors and insert them into the wall.
- Attach the mounting plate to the outlet box using the provided outlet box screws. Ensure that the side of the mounting plate marked GND faces out.
- Secure the mounting plate to the wall using woodscrews inserted through the holes into the drywall anchors.
- Attach the support cable hook on the end of the support cable into a slot located on the mounting plate. Allow the support cable to support the weight of the fixture.
Connecting the Wires:
- Connect the electrical wires according to the diagram provided. Ensure that all wire connectors are secured.
- If your outlet box has a ground wire, connect the fixture’s ground wire to it. Otherwise, connect the fixture’s ground wiredirectly to the mounting plate using the provided green screw.
- Neatly tuck the wire connectors into the outlet box.
Completing the Installation:
- Align the back plate onto the mounting plate and secure it with the rubber washers and screws.
- Separate the cover from the fixture body and install the glass panels into the holder of the fixture body. Secure them with the frame tabs on top and bottom.
- Install four candelabra base bulbs up to 60 watts or CFL/LED equivalent in accordance with the fixture specification. Do not exceed the maximum wattage rating.
- Align the cover onto the fixture body and secure it with screws.
- To prevent moisture from entering the outlet box, use clear silicone sealant to outline the outside of the back plate where it meets the wall. Leave a space at the bottom for moisture to escape.
Your installation is now complete. Restore power to the outlet box and test the fixture. Please note that for proper wiring and installation, it is recommended to have a qualified electrician perform the installation.
INSTALLATION INSTRUCTIONS
Model # 72134-66
READ AND SAVE THESE INSTRUCTIONS
WARNING! SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER.
PREPARING FOR INSTALLATION (Fig. 1)
- Shut off power at the fuse box or circuit breaker box and remove the old fixture including the mounting hardware.
- Carefully unpack your new fixture and lay out all the parts in a clear area. Take care not to misplace any small parts necessary for installation.
- Remove screws (F) and rubber washers (E) and separate mounting plate (C) from the back plate (G).
- Position mounting plate (C) on the wall and mark location of the four drywall anchors (O). Pre-drill the holes for drywall anchors (O). Insert drywall anchors (O) into wall.
- Attach mounting plate (C) using outlet box screws (D) to outlet box (Not included). Note: The side of mounting plate marked “GND” must face out.
- Place woodscrews (N) through holes into drywall anchor (O) to secure mounting plate (C) as shown in Fig.1.
- The support cable (P) is provided to support weight of fixture while wiring. Align fixture to mounting plate (C) and attach hook (Q) on the end of support cable (P) into a slot located on mounting plate (C). Carefully allow support cable (P) to support weight of the fixture while wiring (Fig.1)
**CONNECTING THE WIRES (Fig. 2)
**
-
Connect electrical wires as shown in (Fig.2). Making sure that all wire connectors (B) are secured. If your outlet box (A) has a ground wire (green or bare copper), connect fixture’s ground wire to it. Otherwise, connect fixture’s ground wire directly to mounting plate (C) using green screw provided.
-
Tuck wire connectors neatly into the outlet box (A).
COMPLETING THE INSTALLATION (Fig. 1) -
Align back plate (G) onto mounting plate (C) and secure with rubber washers (E) and screws (F).
-
Remove screws (K), separate cover (M) from fixture body (H), and install glass panels (L) into the holder of fixture body (H) and secure with frame tabs (I) on top and bottom.
-
Install (4) four candelabra base bulbs (J) up to 60 watts or CFL or LED equivalent (not included) in accordance with the fixture specification. —DO NOT EXCEED THE MAXIMUM WATTAGE RATING! (NE PAS DEPASSER LA PUISSANCE NOMINALE MAXIMALE!)
-
Align cover (M) onto fixture body (H) and secure with screws (K).
-
To prevent moisture from entering outlet box (A) and causing a short, use clear silicone sealant to outline outside of back plate (G) where it meets the wall leaving a space at bottom to allow moisture a means to escape.(Fig .3)
Your installation is now complete. Return power to the outlet box and test the
fixture.