ApeStellar AS T626 Wholesale Electron Security Lock Instruction Manual

June 15, 2024
ApeStellar

Programming Instructions

ApeStellar AS T626 Wholesale Electron Security Lock

Parts illstrations

The default master code is 123456, It’s required that you change it t0 a code of your own before programming

ITEM SPECIFICATIONS REMARKS

Battery
(Using only new and non-rechagerable Alkaline
betteries for the best results.)| AA alkaline battery x4 (Operation voltage:4.6~6.0V)| Last up to one year (10 times open/close per day)

ApeStellar AS T626 Wholesale Electron Security Lock - Fig
1

How to use?

Unlock the door from outside

ApeStellar AS T626 Wholesale Electron Security Lock - Fig
2

Unlock the door from inside

ApeStellar AS T626 Wholesale Electron Security Lock - Fig
3

Lock the door from outside
Auto-lock mode
In auto-lock mode, the bolt wil extend out Automaiically in 5100 seconds after unlocking
Manual mode
Press lock button on keypad to one-touch lock

Lock the door from inside
Auto-lock mode

In auto-ock mode, the bolt will extend out Automatically in 5-100 seconds after unlocking
Manual mode
Rotate the turn piece to lock

Quick set up

The default master code is 123466, It’s required that you change it to a code of your own before programming
When setting is unsuccessful the indicator light wil flash red.

ApeStellar AS T626 Wholesale Electron Security Lock - Fig
6

The Pattern of Setup:

Admin Code + ENTER + [ special function number ]+ ENTER

  1. = Add User Code
  2. = Delet User Code
  3. = Delet All User Code
  4. = Change Administrator Code
  5. = Auto-Lock On/Off
  6. = Sound On/Off
  7. = One-time User Code
    1 0 = Vacation Mode
    = Enter

If the function involves a number or user code, then you add + [the number] + ENTER after the pattern above.

For example, ADD A USER CODE

Definitions

  1. Administrator Code
    o Required for programming and feature settings. The defauit Admin code is 123456, please change it before using lockset for the first time.

  2. Auto Lock
    The lock will automatically lock itself within 05-99 seconds when this function is enable. This feature is off by default It can be set if needed.

  3. One-touch Locking
    o Adedicated lock button for one touch locking, lock your door with a single touch. No additional long press or turning/ twisting needed.

  4. Code Protection Function
    0 The operation will stop if unauthorized codes are entered over 4 times.
    o The System wil re-operate again after 60 sec.

  5. Mute Mode
    o You will hear beep sounds when pressing keypad, programming or operating ‘ error. It can be tumed off if needed. LED illumination is still functioning when it’s in mute. As there will be no any warning alarm, we suggest not to mute the beeper if it’s not necessary.

  6. Vacation Mode
    0 This is a security feature for you when you are leaving your home for vacation or long trip. When vacation mode is enable, once the door is locked, all buttons and function will be disable until it’s re-enable. With vacation mode, the system enters into a low-power consumption mode.

  7. One-time User Code
    o One-time user code can be used only once and will be no  longer valid once being used.

  8. Low Battery Waming
    o Beeps and LED flashed red seven times. Replaces with 4 new alkaline batteries. Removing batteries doesn’t erase administrator or user codes.

  9. Unlock with Fake Code
    o User can prevent pin code exposure from strangers by entering random digits before or after correst pin code.

LED/Audio Indicator

Unlock/Valid Programming 1 long beep and LED illuminates green
Lock 2 short beeps and LED illuminates red
Invalid Programming 2 short beeps and LED flashed red twice
Low Voltage Short beeps and LED flashed red seven times
Super Low Voltage 4 short beeps and LED flashed red four times
4 Incorrect Code Entry 2 short beeps and LED illuminates red each attempt
Power On 1 long beep with red light on, 1 short beep with green light on.
After Direction Detection 1 long beep with red+green light on
Incomplete Door Closing/Lock Error 3 long beeps and LED flashed red three

times

Factory Default Settings

SETTING FACTORY DEFAULT
Administrator code 123456
Auto lock Disable
Silent mode Disable
Wrong code entry limit 4 times
Shutdown time 1 min

Troubleshootlng

1. Installation

Question Answer
Why am I not able to pull out the key Check if the tailpiece is vertical.

Please refer to step 2 of installation
Why is the tailpiece jammed| Check if the latch bolt is upside down. Please refer to step 1 of installation
Why am I not able to dose the door| 1. The surface of the strike plate and the bolt should flush with the door
2. Dig the latch bolt hole deeper for the strike
Why do I fail to turn the key nor the turnpiece.Or when you turn the deadbolt out it retracts back in immediately| 1. Deadbolt latch must be retracted when installing.
2.And the tailpiece should be vertical when install the exterior plate.Please refer to step 1 and step 2 of installation
The lock will unlock when you press the button to lock the door, backwards, when you input the code and press the button to unlock the lock, the lock will be locked.| (1) Deadbolt latch must be retracted when installing.
2 And the tailpiece should be vertical when install the exterior plate.Please refer to step 1 and step 2 of installation

2 Operation

Question Answer
Keypad not responding. (1)Make sure the batteries we installed properly

2 The batteries are getting low if battery indicator keeps flashing, please replace with tour new batteries for the best
perforrnance(alkaline batteries only).
3 Make sure the cable is well-connected to the pod and is not damaged during installation
4 Make sure the vacation mode is disable.
Press the button to lock the door when the lock is unlocked. it beeps and doesn’t work. Backwards, when you input the code and press the button
to unlock the lock. the lock will be locked and then press the button. the lock unlocks.| Wrong door handing identification. Please reinstall the lock. Deadbolt latch must be retracted when installing. And the tailpiece should be vertical when install the exterior plate. Please refer to step 1 and step 2 of installation
The lock cannot be programmed| (1)Make sure the Administrator code is correct (2, Make sure the lock is installed
correctly(Deadboll latch must be retracted when installing. And the tailpiece should be vertical when install the exterior plate)
2 Move swiftly during programming. If no digit is pressed for 10 seconds. the system will time out and you will need to restart the procedure.
Administrator code can not be change.| The default acknin code is 123456, please refer to quick set up instructions and restore to factory settings. reprogram again.
Mat should I do if wrong code was entered?| Do not press keypad until keypad stops illuminating and ay again.
I forgot my Administrator code.| Perform a reset. the default admire code is 123458
Can not add a new user code| 1 Make sure the Administrator code is correct
2 Make sure the lock is installed correctly(Deadbolt latch must be retracted when installing. And the tailpiece should be vertical when install the exterior plate)
3. Move swiftly during programming. If no digit is peened tor 10 seconds, the system will tine out and you will need to restart the procedwe.
4 you cannot add a new code if there are already 50 sets user codes exist, if needed delete one of the exist user code or restore the lock’s default settings. A user code must be at least 4-8 digits.
5 Make sure the new user code is not a duplicate and is between 4-8 digits
Ada iodic daes not wont| 1 The batteries are getting low if battery indicator keeps flashing. please replace with four new batteries for the best
performance(skaline batteries only).
2 please refer to quick set up instructions to enable the Auto lock function
Lockset is not able to lock/unlock by keypad| 1  Make sure you have entered the correct user code
2 Make sure the batteries are installed properly
3 The batteries are getting low if battery indicator keeps flashing. please replace with four new batteries for the best
performance(akeline batteries only).
4 Make sure the cable is well-connected to the port and is not damaged during installation
5 Make sure the vacation mode is disable.
6 Wrong door handing identihcation. Please reinstall the lock.Deadboll latch must be
retracted when installing.And the tailpiece should be vertical when install the exterior plate. Please refer to step 1 and step 2 of installation
7 The surface of the strike plate and the bon shoud flush with the door

If the lock appears to be damaged or does not operate properly, please contact customer service for further assistance.

Important Safeguards

  1. Read all instructions in their entirety.
  2. Famillarize yourself with all warning and caution statements.
  3. Remind all famity members of safety precautions.
  4. Restrict access to your jock’s Interior assembly and routinely check your settings to ensure they have not been altered without your knowledge.
  5. Protect your User Codes and Mastercode.
  6. Dispose of used batteries according to local laws and regulations.

CAUTION: Prevent unauthorized entry. This jock has a pre-set User Code and Mastercode. Upon installation and set-up, replace both of these codes with your own. Since anyone with access to the interlor assembly can reset the lock and change the User Codes, you must restrict access to the interior assembly and routinely check the User Codes to ensure they have not been altered without your knowledge.

WARNING: This Manufacturer advises that no lock can provide complete security by itself. This lock may be defeated by forcible or technical means, or evaded by entry elsewhere on the property. No lock can substitute for caution, awareness of your environment, and common sense. Bullder’s hardware Is avallable in multiple performance grades to sult the application. In order to enhance security and reduce risk, you should consult a qualified jocksmith or other security professional.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals