BEGA 24087K3 Wall Luminaire Instructions

June 13, 2024
BEGA

BEGA 24087K3 Wall Luminaire

BEGA-24087K3-Wall-Luminaire-fig-1

Product Information

  • Product Name: Wandleuchte Wall luminaire Applique
  • Product Number: 24 087
  • IP Rating: IP 65

Overvoltage Protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547. To achieve additional protection against transients and other potential issues, we recommend using separate overvoltage protection components. You can find these components on our website at www.bega.com.

Safety

The installation and operation of this luminaire must comply with national safety regulations. Only a qualified electrician should carry out the installation and commissioning. The manufacturer is not liable for any damage caused by improper use or installation. If any modifications are made to the luminaire, the person responsible for these modifications will be considered the manufacturer.

Technical Specifications

Module Designation| Lamp Type| Connected Wattage (Module)| Connected Wattage (Luminaire)| Colour Temperature| Colour Rendering Index (CRI)| Module Luminous Flux| Luminaire Luminous Flux| Luminaire Luminous Efficiency
---|---|---|---|---|---|---|---|---
24 087 K3| 2x LED-0887/830| 10 W| 11.5 W| 3000 K| CRI > 80| 1460 lm| 410 lm| 35.7 lm / W
24 087 K4| 2x LED-0887/840| 10 W| 11.5 W| 4000 K| CRI > 80| 1550 lm| 435 lm| 37.8 lm / W

Desiccant Pouch

In order to guarantee the maximum service life of the electrical components, a desiccant pouch is included with the luminaire. Remove the desiccant pouch from the foil packaging and place it in the position marked by the red information label immediately before finally closing the luminaire. Do not remove the desiccant bag from the luminaire housing as it is needed to remove residual moisture.

Product Usage Instructions

Luminaire Installation

  1. Push the plug into the coupler as far as it will go.
  2. Ensure that the gasket is positioned correctly.
  3. Install the luminaire top, press-on, and tighten the screw.
    Note: Please ensure that the installation is done by a qualified electrician and complies with national safety regulations.

Spares

  • LED Power Supply Unit – DEV-0332/350
  • LED Module 3000 K – LED-0887/830
  • LED Module 4000 K – LED-0887/840
  • Gasket for Wall Box – 83 000 877
  • Gasket for Housing – 83 000 885

DIMENSION

Application

  • Wall luminaire with shielded light.
  • Light emission 2 × 90°.
  • Fully glare free light for lighting wall surfaces and for interior or exterior lighting design.

Product description

  • Luminaire made of aluminium alloy, aluminium and stainless steel
  • BEGA Unidure® coating technology
  • Safety glass
  • Optical silicone lens
  • Light sector 2 × 90°
  • Mounting plate with 4 mounting holes ø 4.5mm
  • Distance apart 86 x 86mm
  • 2 cable entries for through-wiring of mains supply cable ø 7-12mm, max. 5G1.5@
  • Connecting terminal 2.5@ with plug connection
  • Earth conductor connection
  • LED power supply unit
  • 220-240 V x 0/50-60 Hz
  • DC 176-276 V
  • DALI-controllable
  • Basic insulation is provided between the mains and control cables
  • BEGA Thermal Control®
  • Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire
  • Safety class I
  • Protection class IP 65
  • Dust-tight and protection against water jets
  • Impact strength IK06
  • Protection against mechanical impacts < 1 joule
  • r – Safety mark
  • c – Conformity mark
  • Weight: 1.4 kg

Overvoltage protection

  • The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
  • To achieve an additional protection against e.g. transients, etc. we recommend separate overvoltage protection components.
  • You can find them on our website at www.bega.com.

Safety

  • The installation and operation of this luminaire are subject to national safety regulations.
  • Installation and commissioning may only be carried out by a qualified electrician.
  • The manufacturer accepts no liability for damage caused by improper use or installation.
  • If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

SPECIFICATION

  • Lamp
    • Module connected wattage 10 W
    • Luminaire connected wattage 11.5 W
    • Rated temperature ta=25 °C
    • Ambient temperature ta max=50 °C
  • 24 087K3
    • Module designation
    • 2x LED-0887/830
    • Colour temperature 3000 K
    • Colour rendering index CRI >80
    • Module luminous flux 1460 lm
    • Luminaire luminous flux 410 lm
    • Luminaire luminous efficiency 35,7 lm/W
  • 24 087K4
    • Module designation
    • 2x LED-0887/840
    • Colour temperature 4000 K
    • Colour rendering index CRI >80
    • Module luminous flux 1550 lm
    • Luminaire luminous flux 435 lm
    • Luminaire luminous efficiency 37,8 lm/W

Installation

  • Undo hexagon socket head screw (wrench size 3mm) through the opening in the luminaire housing up to the stop and lift luminaire top.
  • Lead the mains supply cable through the cable entry of the luminaire base.
  • Fix luminaire base with enclosed fixing screws diagonally on the mounting surface.
  • Make the earth conductor connection and the electrical connection.
  • For digital control please use the connecting terminal DA, DA.
  • In case this terminal is not used the luminaire will be operated at full light output.
  • In order to guarantee the maximum service life of the electrical components, the enclosed desiccant pouch must be placed in the luminaire.
  • Remove the desiccant pouch from the foil packaging and place it in the position marked by the red information label immediately before finally closing the luminaire.
  • Push plug into coupler as far as it will go.
  • Make sure that gasket is positioned correctly. Install the luminaire top, press-on and tighten screw.

Cleaning · Maintenance

  • Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
  • Do not use high pressure cleaners.

Please note:

  • Do not remove the desiccant bag from the luminaire housing.
  • It is needed to remove residual moisture.

Replacing the LED module

  • The designation of the LED module is noted on a label in the luminaire.
  • The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
  • The module can be replaced by qualified persons using standard tools.
  • Disconnect the system and open the luminaire.
  • Please follow the installation instructions for the LED module.
  • Inspect and, if necessary, replace the luminaire gaskets.
  • Defective glass must be replaced.
  • Close the luminaire.

Spares

  • LED power supply unit DEV-0332/350
  • LED module 3000 K LED-0887/830
  • LED module 4000 K LED-0887/840
  • Gasket wall box 83 000 877
  • Gasket housing 83 000 885

ABOUT COMPANY

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals