BEGA 51013.4 Ceiling Luminaire LED For Indoor Use Instruction Manual

June 13, 2024
BEGA

BEGA 51013.4 Ceiling Luminaire LED For Indoor Use

BEGA-51013-4-Ceiling-Luminaire-LED-For-Indoor-Use-
product

Product Information

Product Name 51 013.4 K3
Lamp Module Connected Wattage 26.4 W
Luminaire Connected Wattage 29.5 W
Colour Temperature 3000 K
Colour Rendering Index (CRI) > 90
Module Luminous Flux 3970 lm
Luminaire Luminous Flux 2455 lm
Luminaire Luminous Efficiency 83.2 lm / W

Product Usage Instructions

Installation:

  1. Avoid touching the light output opening of the LED directly during installation or relamping.
  2. To remove the synthetic cover, turn it anti-clockwise as far as it will go while simultaneously pushing the synthetic cover up against the luminaire fitting.

Safety:

  • The installation and operation of this luminaire are subject to national safety regulations.
  • Installation and commissioning should only be carried out by a qualified electrician.
  • The manufacturer does not accept liability for damage caused by improper use or installation.
  • If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage Protection:
The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547. For additional protection against transients, it is recommended to use separate overvoltage protection components. These can be found on our website at www.bega.com.

Spares:

  • Synthetic cover: 15 000 633 71 001 760 L13
  • Shield: 75 001 903 .1K 3
  • LED unit 3000 K: 15 000 633 71 001 760 L13

Ceiling luminaire for indoor use

DIMENSIONS

BEGA-51013-4-Ceiling-Luminaire-LED-For-Indoor-Use-fig-
\(1\)

Instructions for use

Application
Ceiling luminaire · indoor luminaire impact resistant synthetic diffuser and metal housing for non-glare light deflected downwards.

Product description

  • Ceiling luminaire »STUDIO LINE« Aluminium luminaire housing, Colour velvet black finish, Inside hue matt brass Metal luminaire mounting plate, finish colour white Impact resistant synthetic diffuser, white, with bayonet closure 2 mounting holes ø 5.5 mm Distance apart 230 mm 2 cable entries for through-wiring for mains cable up to ø 10,5 mm max. 5 x 1.5@ Connection terminal 2.5@
  • Earth conductor connection LED power supply unit 220-240 V x 0/50-60 Hz
  • DALI-controllable Basic insulation is provided between the mains and control cables BEGA Thermal Switch® Temporary thermal shutdown to protect temperature-sensitive components
  • Safety class I
  • Impact strength IK10
  • Protection against mechanical impacts < 20 joule
  • Safety mark
  • Conformity mark
  • Weight : 2.6 kg

Lamp

  • Module connected wattage : 26.4 W

  • Luminaire connected wattage: 29.5 W

  • Rated temperature: ta = 25 °C

  • Ambient temperature: ta max = 40 °C
    51 013.4 K3

  • Colour temperature: 3000 K

  • Colour rendering index: CRI > 90

  • Module luminous flux: 3970 lm

  • Luminaire luminous flux: 2455 lm

  • Luminaire luminous efficiency: 83,2 lm / W

Installation

LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping.

BEGA-51013-4-Ceiling-Luminaire-LED-For-Indoor-Use-fig-
\(4\)

  • Before installing onto the ceiling the luminaire mounting plate must be inserted into the luminaire housing. Thereby pass the mains supply cable through the grommet into luminaire mounting plate.
  • Fix monting plate inside the luminaire housing with enclosed or any other suitable fixing material on to the mounting surface.
  • Dismantle the mains supply cable approx. 60 mm.
  • Pull silicone sleeves over the wires and make earth and electrical connection to the terminals. For digital control please use the connecting terminal DA, DA.
  • In case this terminal is not used the luminaire will be operated at full light output.
  • In order to securely install the synthetic cover in the fitting, the top opening of the synthetic cover must be inserted into the luminaire housing at an angle.
  • Make sure that at least one of the recesses in the edge of the synthetic cover matches the position of one of the lugs on the fitting see drawing.

IMPORTANT:
Turn the synthetic cover upwards into the fitting as far as it will go. Now secure the synthetic cover in the fitting by turning it clockwise. Only then is the synthetic cover held securely in place and resistant to vibration. The synthetic cover is removed by turning it anti-clockwise as far as it will go while simultaneously pushing the synthetic cover up against the luminaire fitting.

Safety
The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician. The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection
The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547. To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.

You can find them on our website at www.bega.com.

Cleaning  Maintenance

Clean luminaire regularly with solvent-free cleansers from dirt.

Replacement of the LED unit

  • The designation of the LED unit is noted on a label in the luminaire.
  • The light colour and light output of BEGA replacement units correspond to those of the LED units originally fitted. The LED unit can be replaced by qualified persons using standard tools.
  • Disconnect from main supply.
  • Unscrew synthetic diffuser from luminaire housing by turning it counter-clockwise. Disassemble LED unit.
  • Assemble LED replacement unit.
  • Note installation instructions of the LED unit. Screw in synthetic diffuser by turning it clockwise.
  • A damaged synthetic diffuser must be replaced.

Spares

  • Synthetic cover: 15 000 633
  • Shield: 71 001 760 L13
  • LED unit 3000 K: 75 001 903 .1K 3

BEGA Gantenbrink-Leuchten KG  Postfach 31 60  58689 Menden info@bega.com www.bega.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals