BEGA 51013.2 Ceiling Luminaire For Indoor Use Instruction Manual
- June 13, 2024
- BEGA
Table of Contents
**BEGA 51013.2 Ceiling Luminaire For Indoor Use
**
DIMENSIONS
Application
Ceiling luminaire · indoor luminaire impact resistant synthetic diffuser and metal housing for non-glare light deflected downwards.
Product description
Ceiling luminaire »STUDIO LINE« Aluminium luminaire housing, Finish Colour
velvet black, Inside hue matt aluminium Metal luminaire mounting plate, finish
colour white Impact resistant synthetic diffuser, white, with bayonet closure
2 mounting holes ø 5.5mm Distance apart 230mm 2 cable entries for through-
wiring for mains cable up to ø 10,5 mm max. 5 x 1.5@ Connection terminal 2.5@
Earth conductor connection LED power supply unit 220-240 V 0/50-60 Hz DALI-
controllable Basic insulation is provided between the mains and control cables
BEGA Thermal Switch® Temporary thermal shutdown to protect temperature-
sensitive components Safety class I Impact strength IK10 Protection against
mechanical impacts < 20 joule
r – Safety mark
– Conformity mark
Weight: 2.6 kg
Lamp
Module connected wattage 26.4 W
Luminaire connected wattage 29.5 W
Rated temperature ta=25 °C
Ambient temperature ta max=40 °C
51 013.2K3
Colour temperature 3000 K
Colour rendering index CRI >90
Module luminous flux 3970 lm
Luminaire luminous flux 2576 lm
Luminaire luminous efficiency 87,3 lm/W
Installation
LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during
installation or relamping.
Before installing onto the ceiling the luminaire mounting plate must be
inserted into the luminaire housing.
Thereby pass the mains supply cable through the grommet into luminaire
mounting plate. Fix monting plate inside the luminaire housing with enclosed
or any other suitable fixing material on to the mounting surface. Dismantle
the mains supply cable approx. 60 mm.
Pull silicone sleeves over the wires and make earth and electrical connection
to the terminals. For digital control please use the connecting terminal DA,
DA.
In case this terminal is not used the luminaire will be operated at full light
output.
In order to securely install the synthetic cover in the fitting, the top
opening of the synthetic cover must be inserted into the luminaire housing at
an angle.
Make sure that at least one of the recesses in the edge of the synthetic cover
matches the position of one of the lugs on the fitting – see drawing.
IMPORTANT:
Turn the synthetic cover upwards into the fitting as far as it will go. Now
secure the synthetic cover in the fitting by turning it clockwise.
Only then is the synthetic cover held securely in place and resistant to
vibration. The synthetic cover is removed by turning it anti-clockwise as far
as it will go while simultaneously pushing the synthetic cover up against the
luminaire fitting
Safety
The installation and operation of this luminaire are subject to national
safety regulations.
Installation and commissioning may only be carried out by a qualified
electrician. The manufacturer accepts no liability for damage caused by
improper use or installation.
If subsequent modifications are made to the luminaire, the person responsible
for these modifications shall be considered the manufacture
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e.g. transients, etc. we recommend
separate overvoltage protection components. You can find them on our website
at www.bega.com.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt.
Replacement of the LED unit
The designation of the LED unit is noted on a label in the luminaire.
The light colour and light output of BEGA replacement units correspond to
those of the LED units originally fitted. The LED unit can be replaced by
qualified persons using standard tools.
Disconnect from main supply.
Unscrew synthetic diffuser from luminaire housing by turning it counter-
clockwise.
Disassemble LED unit.
Assemble LED replacement unit.
Note installation instructions of the LED unit.
Screw in synthetic diffuser by turning it clockwise.
A damaged synthetic diffuser must be replaced.
Spares
Synthetic cover 15 000 633
Shield 71 001 760 L12
LED unit 3000 K 75 001 903 .1K 3
BEGA Gantenbrink-Leuchten KG · Postfach 3160 ·
58689 Menden · info@bega.com ·
www.bega.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>