SFA 1337 12.22 Sanifos 1000 TWIN GR Instruction Manual
- June 13, 2024
- SFA
Table of Contents
SFA 1337 12.22 Sanifos 1000 TWIN GR
Copyright / Disclaimer – SANIFOS Installation and Maintenance Manual – Original operating instructions All rights reserved. The contents of this document must not be reproduced, modified or disclosed to third parties except upon written consent from the manufacturer. This document may be subject to change without notice. Status of the operating instructions: December 2022
SAFETY
WARNING
Installation and servicing must be done by the relevant qualified person(s).
ELECTRICAL CONNECTIONS:
The electrical installation must be done by a qualified electrician. The
device’s power supply must be connected to ground (class I) and protected by a
high sensitivity differential circuit breaker (30 mA). Devices without plugs
must be connected to a main switch on the power supply which disconnects all
poles (contact separation distance of at least 3 mm). The connection must be
used exclusively to provide the power to the product. If the power cord is
damaged, to prevent possible danger, it must be replaced or repaired by a
qualified electrician. These operating instructions contain basic instructions
which have to be observed during setup, operation and maintenance. For this
reason, these operating instructions must be read before installation and
commissioning by the installation technician as well as the user, and must be
permanently available at the location of the device. Not only do general
safety instructions have to be observed, but all the safety instructions
mentioned.
Labelling of safety notices
Danger
This symbol indicates general hazards, which can lead to death or serious
injury, if not avoided.
Warning
This term defines a hazard which could cause a risk to the machine and its
operation, if it is not taken into account
Dangerous area
This symbol characterises hazards that could lead to death or
Dangerous voltage
This symbol characterises dangers associated with the voltage and provides
information on voltage protection.
Property damage
This symbol, in combination with the keyword ATTENTION, characterises dangers
to the machine and its proper operation.Instructions attached directly to the
machine and its components, such as rotation arrow,
marks for specific connections, must be observed and kept in fully legible
condition.
Installer / operator
Prior to operation, maintenance, inspection or installation these instructions
must be read and understood in full. The installer/operator must also ensure
these instructions are available on-site at all times.
Hazards caused by non-observation of safety instructions
Not observing the safety instructions may endanger persons and may have
consequences for the immediate environment and the pump station. Not observing
these safety instructions will result in the loss of all claims for damages.
In detail, not observing these safety instructions may cause the following
hazards, for example:
- Malfunction and damage of the machine/system
- Danger to persons caused by electrical, mechanical and chemical effects
- Damage to the environment and danger to personnel caused by leakage of wastewater Along with these operating instructions, existing national and local regulations as well as potential in-company work, operating and safety instructions applying to the user/site must be observed.
Safety instructions for user/operator
- Hot or cold machine parts could become a hazard, these parts must not be handled by the user
- Touch protection for moving parts (e.g. coupling) must not be removed from the machine whilst in operation/without being isolated.
- Leakage (of the tank seal, for example) of hazardous materials (e.g. corossive, toxic, hot) must be rectified immediately so no danger is caused to persons and the environment. Legal regulations must be observed in this regard.
- Hazards caused by electricity (ie. exposed electrical components during servicing) must be safeguarded against (eg. isolation of the product and any necessary PPE alongside any additional regulations that apply).
Safety instructions for maintenance, inspection and installation work
The user has to make sure that all maintenance, inspection and installation
work is carried out by authorised and qualified personnel only, who have read
the operating instructions. Work on the machine may be carried out only when
the unit is isolated and made safe to do so. Pumps or pump assemblies, which
convey media hazardous to health, must be handled with caution and PPE is to
be used where necessary. After works are completed all safety and protection
devices have to be fitted again and/or have to be made functional again.
Before restart, the points listed in the chapter on initial commissioning
should be observed.
Unauthorised modification and spare parts usage
Modifications or changes to the machine shall be permissible only after
consultation with the manufacturer. Original spare parts and accessories
authorised by the manufacturer serve to ensure safety and longevity of the
product.The use of other parts may results in the loss of liability for the
consequences that may occur unless advised otherwise by the manufacturer.
Incorrect operating modes
The operational safety of the machine supplied is ensured only when used as
intended according to Section 2 – General aspects of the operating
instructions. The performance limits indicated in the data sheet must by no
means be exceeded.
GENERAL ASPECTS
Liability
If operating instructions are not followed – in particular the safety
instructions and unauthorised modifications are made to the product (eg. the
installation of non-original spare parts) warranty claims may be void. The
manufacturer assumes no liability for any damage resulting from this.
Technical data
SANIFOS® – installations for single or twin pump systems Pumps with a pressure
outlet of 40-50mm and a performance of up to approx.
2.2kW
Component Materials
- Tank HDPE
- Coupling system Cast iron/SS
- Shut-off/Check valve CPVC/Rubber
- Hydraulic Assembly CPVC
- Motor PP+SS (GR) or GG25+SS (ZFS)
Field of application
The SANIFOS® range of pumping stations serve to dispose of (collecting and
conveying) domestic and commercial greywater and blackwater, typically when
draining from fixtures below the sewer invert level.
Scope of delivery
The packaged pumping station SANIFOS® basis is delivered complete with:
- Guide rail and coupling system (twin pump versions)
- shut-off valve(s) DN 50
- check valve(s) DN 50
- complete internal hydraulic assembly with screw connections
- submersible pump(s) D 40/50 (see separate operating instructions)
- float switches
- control/alarm panel
- threaded Class A access cover
- 316SS lifting chains + fittings
- IP68 Cable connectors
TRANSPORT AND STORAGE
Transport
The packaged pumping stations from the series SANIFOS® must not be thrown or
dropped. Moreover, they shall be kept upright during transportation.
Storage
For best practice storage or intermediate warehousing, it is suggested to keep
the system in a cool, dark, dry and frost-proof place. The system should be
kept in an upright position.
DESCRIPTION
General description
The pumping station is pre-fitted with hydraulic assembly including non-return
& isolation valves. For ease of installation, only the incoming waste/drain
line, rising main,venting line, level control and power supply need to be
connected.
Design and functionality
Twin motor models come complete with guide rail coupling system pre-mounted,
to which the pump is engaged prior to commissioning. The pump can be lifted
out of the tank via the lifting chain without loosening screw connections in
the shaft. Depending on the size of the pump, lifting gear might be necessary
to lift it out. This way, maintenance and repair work on the pump is possible
outside the tank. In order to prevent backflow of the water column being in
the pressure line at the ball check valve during maintenance and repairing
work, a shut-off valve is mounted before the check valve in the pressure line.
INSTALLATION
Excavation
The correct excavation, concrete ballast & backfill is essential to stop
potential hydrostatic uplift along with lateral ground load deformation of the
in-ground pump chamber. Hydrostatic uplift is a term used for the action of
subsurface water applying pressure to the underside of the tank, whilst
lateral load deformation can be caused by lateral ground movement forces
pushing against the walls of the chamber/tank.
Note: Make sure chamber is half filled with water whilst completing ballast till commissioning.
WARNINGS
Safe work method and correct shoring procedures must be followed in all
excavation works excavon works The following excavation dimensions along with
ballast and backfill procedures must be followed must be followed to maintain
warranty of the pump chamber/tank.
Motor Installation
- Attach the chain to the pump and connect to the top of the tank using the hook provided
- Slide the pump(s) onto, and down the guide bars to the bottom of the tank where the pump will seat on the foot coupling
Electrical Connection
NOTE
SANIFOS® 1000 Twin GR floats and motors must be connected to the SMART
controller via the IP68 waterproof terminal connectors provided for this model
only. It is imperative that you respect the colours of the cables when making
the connections. (See page 7) After motor installation has been completed
wiring of floats and motors back to controller should be finalized in
preparation for commissioning. If Sanifos ZFS Twin & ZFS Single require cable
extensions correct cable connection and sealing via heat shrink or resin
filled jointing is crucial.
Preparing the terminal blocks (Sanifos 1000 Twin GR only)
COMMISSIONING
Before commissioning, all connections must be checked again for correct installation and watertightness. The shut-off valve must be open. See relevant motor and controller manuals for full commissioning information.
MAINTENANCE / SERVICING
For help finding the relevant service-person please contact SFA Australia directly. Maintenance includes regular visual inspection of the complete system. Water should be run into the tank using a connected fixture and the pumping process should be checked. Check for correct cycling of the pump(s) and that all hydraulic fittings are functioning as intended. Note – in twin pump models, to be functioning correctly,the pumps should alternate cycling with each activation of the unit. After maintenance has been carried out, the maintenance interval indicator on the controller should be reset. Maintenance should only ever be carried out by qualified individuals.
WARRANTY & CONTACT INFORMATION
General Warranty information
Warranty only provides coverage of issues caused by material or manufacturing
defects of the inground pump station. The warranty excludes all damage
attributable to improper use, wear and tear or incorrect installation. We do
not assume any liability for consequential damages which occur due to a
failure of the device. In case of of a suspected product fault, contact SFA
Australia or your supplier. The pump, controller and internal assembly is
covered under a 2 year warranty, assuming the warranty conditions are met. The
tank is covered under a 15 year warranty (per AS1546) assuming the warranty
conditions are met. Damage to the tank/other components due to incorrect
ballast configuration will not be covered.
Warranty Conditions
This warranty will apply only under all of the following conditions:
- The item has been installed by a licensed plumber
- All relevant electrical connections and safeties have been installed by a qualified electrician
- Failure is due to a fault in the manufacture of the product
- Proof of purchase (including the date of purchase) is provided
- The installation of the product is in accordance with the instructions provided and all relevant standards
- No use of this product for disposal of any foreign bodies* or products such as solvents, paints, caustic soda or acids
- No use of this product for disposal of feminine hygiene products, wet wipes or paper hand towels in the system. See Saniflo SFA Australia website for full warranty terms and conditions.
AUSTRALIA
- SFA Saniflo Australia Pty
- Ltd Unit 9-10, 25 Gibbes
- Street Chatswood
- NSW 2067
- Tel. +61 298 826 200
NEW ZEALAND
- SFA Saniflo New Zealand Ltd
- PO Box 383 Royal Oak,
- Auckland 1345
- Tel: 09 390 4615
SERVICE HELPLINES
- Australia
- Tel +1300 554 779
- New Zealand
- Tel 0800 107 264
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>