OVATIONREVEP3IP Multi Color Full Spectrum User Manual
- August 22, 2024
- Ovation
Table of Contents
3IP Multi Color Full Spectrum
User Manual
OVATIONREVEP3IP Multi Color Full Spectrum
Edition Notes
The Ovation Rêve P-3 IP User Manual includes a description, safety
precautions, installation, programming, operation and maintenance instructions
for the Ovation Rêve P-3 IP as of the release date of this edition.
Trademarks
Chauvet, Chauvet Professional, the Chauvet logo, Ovation, and Ovation Rêve are
registered trademarks or trademarks of Chauvet & Sons, LLC (d/b/a Chauvet and
Chauvet Lighting) in the United States and other countries. Other company and
product names and logos referred to herein may be trademarks of their
respective companies.
Copyright Notice
The works of authorship contained in this manual, including, but not limited
to, all designs, text, and images are owned by Chauvet.
© Copyright 2024 Chauvet & Sons, LLC. All rights reserved.
Electronically published by Chauvet in the United States of America.
Manual Use
Chauvet authorizes its customers to download and print this manual for
professional information purposes only. Chauvet expressly prohibits the usage,
copy, storage, distribution, modification, or printing of this manual or its
content for any other purpose without written consent from Chauvet.
Document Printing
For best results, print this document in color, on letter size paper (8.5 x 11
in), double-sided. If using A4 paper (210 x 297 mm), configure the printer to
scale the content accordingly.
Intended Audience
Any person installing, operating, and/or maintaining this product should
completely read through the guide that shipped with the product, as well as
this manual, before installing, operating, or maintaining this product.
Disclaimer
Chauvet believes that the information contained in this manual is accurate in
all respects. However, Chauvet assumes no responsibility and specifically
disclaims any and all liability to any party for any loss, damage or
disruption caused by any errors or omissions in this document, whether such
errors or omissions result from negligence, accident or any other cause.
Chauvet reserves the right to revise the content of this document without any
obligation to notify any person or company of such revision, owever,
Chauvet has no obligation to make, and does not commit to make, any such
revisions.
Document Revision
Go to www.chauvetprofessional.com for
the latest version.
Revision | Date | Description |
---|---|---|
4 | 1/2024 | Updated What’s included section |
Before You Begin
What Is Included
- Ovation Rêve P-3 IP
- Seetronic Powerkon IP65 power cable
- Narrow, Medium, Wide, and Very Wide lenses
- Gel frame
- Omega bracket with mounting hardware
- Quick Reference Guide
Claims
Carefully unpack the product immediately and check the container to make sure
all the parts are in the package and are in good condition.
If the box or the contents (the product and included accessories) appear
damaged from shipping, or show signs of mishandling, notify the carrier
immediately, not Chauvet. Failure to report damage to the carrier immediately
may invalidate a claim. In addition, keep the box and contents for inspection.
For other issues, such as missing components or parts, damage not related to
shipping, or concealed damage, file a claim with Chauvet within 7 days of
delivery.
Text Conventions
Convention | Meaning |
---|---|
1–512 | A range of values |
50/60 | A set of values of which only one can be chosen |
Settings | A menu option not to be modified |
< ENTER> | A key to be pressed on the product’s control panel |
Symbols
Symbol | Meaning |
---|---|
Critical installation, configuration, or operation information. Not |
following these instructions may make the product not work, cause damage to
the product, or cause harm to the operator.
| Important installation or configuration information. The product may not
function correctly if this information is not used.
| Useful information.
Any reference to data or power connections in this manual assumes the use of
Seetronic IP-rated cables.
The term “DMX” used throughout this manual refers to the USITT DMX512-A
digital data transmission protocol.
Safety Notes
Read all the following safety notes before working with this product. These
notes contain important information about the installation, usage, and
maintenance of this product.
This product contains no user-serviceable parts. Any reference to servicing in
this User Manual will only apply to properly trained, certified technicians.
Do not open the housing or attempt any repairs.
All applicable local codes and regulations apply to proper installation of
this product.
- The luminaire is intended for professional use only.
- The luminaire should be positioned so that prolonged staring into the luminaire at a distance closer than 3.3 ft (1 m) is not expected.
- If the external flexible cable or cord of this luminaire is damaged, it shall be replaced by a special cord or cord exclusively available from the manufacturer or its service agent.
- The light source contained in this luminaire shall only be replaced by the manufacturer or its service agent or a similar qualified person.
- CAUTION:
- This product’s housing may be hot when operating. Mount this product in a location with adequate ventilation, at least 20 in (50 cm) from adjacent surfaces.
- When transferring the product from extreme temperature environments, (e.g., cold truck to warm humid ballroom) condensation may form on the internal electronics of the product. To avoid causing a failure, allow the product to fully acclimate to the surrounding environment before connecting it to power.
- Flashing light is known to trigger epileptic seizures. User must comply with local laws regarding notification of strobe use.
- ALWAYS:
- Disconnect from power before cleaning the product or replacing the fuse.
- When using an IP65-rated product in an outdoor environment, use IP65- (or higher) rated power and data cable.
- Replace and secure IP-rated protective covers to all power, data, USB, or other ports when not in use.
- Replace the fuse with the same type and rating.
- Use a safety cable when mounting this product overhead.
- Connect this product to a grounded and protected circuit.
- DO NOT:
- Open this product. It contains no user-serviceable parts.
- Look at the light source when the product is on.
- Leave any flammable material within 20 cm of this product while operating or connected to power.
- Connect this product to a dimmer or rheostat.
- Operate this product if the housing, lenses, or cables appear damaged.
- Submerge this product (adhere to standards for the published IP rating). Regular outdoor operation is fine.
- Permanently install outdoors in locations with extreme environmental conditions. This includes, but is not limited to:
- Exposure to a marine/saline environment (within 3 miles of a saltwater body of water).
- Locations where normal temperatures exceed the temperature ranges in this manual.
- Locations that are prone to flooding or being buried in snow.
- Other areas where the product will be subject to extreme radiation or caustic substances.
- ONLY use the handles or the hanging/mounting brackets to carry this product.
- The maximum ambient temperature is 113 °F (45 °C). Do not operate this product at higher temperatures.
- The minimum startup temperature is -4°F (-20°C). Do not start the product at lower temperatures.
- The minimum ambient temperature is -22°F (-30°C). Do not operate the product at lower temperatures.
- To eliminate unnecessary wear and improve its lifespan, during periods of non-use completely disconnect the product from power via breaker or by unplugging it.
- In the event of a serious operating problem, stop using immediately.
If a Chauvet product requires service, contact Chauvet Technical Support.
This device complies with Part 15 Part B of the FCC rules. Operation is
subject to the following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Any changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate the equipment.
Expected LED Lifespan
Over time, use and heat will gradually reduce LED brightness. Clustered LEDs
produce more heat than single LEDs, contributing to shorter lifespans if
always used at full intensity. The average LED lifespan is 40,000 to 50,000
hours. To extend LED lifespan, maintain proper ventilation around the product,
and limit the overall intensity.
Introduction
Description
The Ovation Rêve P-3 IP is the brightest IP65-rated multi-color full-spectrum-
white LED PAR. An outdoor fixture with unsurpassed power and quality of light
that incorporates all the advancements of our Ovation Rêve RGBAM LED source,
and offers the versatility of Narrow, Medium, Wide and Very Wide lenses.
Linear color temperature presets from 2800 K to 8000 K with high CRI and CQS.
Adjustable PWM (Pulse Width Modulation) avoids on camera flicker. Indoors or
out, a powerful instrument for theatrical, house of worship, special events,
rental and production use.
Features
- Full-spectrum LED PAR lighting fixture for rental/production use as well as special event and theatre.
- Fully IP65 rated for seasonal use indoors or out
- Interchangeable Narrow, Medium, Wide, and Very Wide lenses.
- USB port for fixture software updates
- Linear color temperature presets from 2800 K to 8000 K with high CRI and CQS
- +/- Green adjustment and emulated red-shift via DMX or on-board control
Product Overview
# | Name |
---|---|
1 | LCD display |
2 | DMX in |
3 | Power in |
4 | Fuse holder |
5 | Power out |
6 | DMX out |
7 | Menu buttons |
8 | USB C port |
Product Dimensions
Setup
AC Power
The Ovation Rêve P-3 IP has an auto-ranging power supply and it can work with
an input voltage range of 100 to 240 VAC, 50/60 Hz.
To determine the product’s power requirements (circuit breaker, power outlet,
and wiring), use the current value listed on the label affixed to the
product’s back panel, or refer to the product’s specifications chart.
The listed current rating indicates the product’s average current draw under
normal conditions.
- Always connect the product to a protected circuit (a circuit breaker or fuse). Make sure the product has an appropriate electrical ground to avoid the risk of electrocution or fire.
- To eliminate unnecessary wear and improve its lifespan, during periods of non-use completely disconnect the product from power via breaker or by unplugging it.
Never connect the product to a rheostat (variable resistor) or dimmer circuit,
even if the rheostat or dimmer channel serves only as a 0 to 100% switch.
AC Plug
The Ovation Rêve P-3 IP comes with a power input cable terminated with a
Seetronic Powerkon A connector on one end and an Edison plug on the other end
(U.S. market). If the cable has no plug or it is necessary to change the plug,
use the table below to wire a plug.
Connection | Wire (U.S.) | Wire (Europe) | Screw Color |
---|---|---|---|
AC Live | Black | Brown | Yellow or Brass |
AC Neutral | White | Blue | Silver |
AC Ground | Green/Yellow | Green/Yellow | Green |
Fuse Replacement
- Disconnect this product from the power outlet.
- Using a flat-head screwdriver, unscrew the fuse holder cap from the housing.
- Remove the blown fuse and replace with another of the same type and rating (T 6.3 A, 250 V).
- Screw the fuse holder cap back in place and reconnect power.
Power Linking
It is possible to power link Ovation Rêve P-3 IP products. See the table below
for the current draw at each voltage and frequency:
| 100 V, 60 Hz| 120 V, 60 Hz| 208 V, 60 Hz| 230 V, 50 Hz|
240 V, 50 Hz
---|---|---|---|---|---
Current Draw| 2.78 A| 2.31 A| 1.38 A| 1.25 A| 1.22 A
DMX Linking
The Ovation Rêve P-3 IP can be linked to a DMX controller using a 3-pin or
5-pin DMX connection. If using other DMX-compatible products with this
product, it’s possible to control each individually with a single DMX
controller.
DMX Personalities
The Ovation Rêve P-3 IP uses a 3-pin or 5-pin DMX data connection for the 1
Ch, 4 Ch, 5 Ch, 7 Ch, 11 Ch, 13 Ch1, 13 Ch2, 17 Ch, and HSV DMX personalities.
- Refer to the Operation chapter to learn how to configure the Ovation Rêve P-3 IP to work in these personalities.
- The DMX Channel Assignments and Values section provides detailed information regarding the DMX personalities.
For information about DMX standards, Master/Slave connectivity, or the DMX
cables needed to link this product to a DMX controller, download the DMX
Primer from the Chauvet website:
www.chauvetprofessional.com.
Remote Device Management
Remote Device Management (RDM) is a standard for allowing DMX-enabled
devices to communicate bi- directionally along existing DMX cabling. Check the
DMX controller’s User Manual or with the manufacturer as not all DMX
controllers have this capability. The Ovation Rêve P-3 IP supports RDM
protocol that allows feedback to make changes to menu map options.
Master/Slave Connectivity
The Master/Slave mode allows an Ovation Rêve P-3 IP (the master) to control
one or more Ovation Rêve P-3 IP products (the slaves) without a DMX
controller. Once Ovation Rêve P-3 IP becomes the master when running an auto
or custom program, or in Static mode.
Each slave’s control panel must be configured to operate in Slave mode. During
Master/Slave operation, the slaves will operate in unison with the master
DO NOT connect a DMX controller to products operating in Master/Slave mode.
The DMX controller signals may interfere with the signals from the master.
- The Operation section of this manual provides detailed instructions on how to configure the master and slaves.
- For more information about DMX standards or the DMX cables needed to link this product to a DMX controller, download the DMX primer from the Chauvet website: www.chauvetprofessional.com.
USB Software Update
The Ovation Rêve P-3 IP allows for software update through USB using the
built-in USB port. To update the software using a USB flash drive, do the
following:
-
Power on the product and plug the flash drive into the USB port.
-
Once the flash drive has been detected, the message “Upgrade?” will be displayed. Select “YES” and Press
. A list of the updated software files will be displayed.
• If no valid firmware file is detected in the USB, the screen will display “No File”. -
Select the file that needs to be uploaded.
• Be sure to select the correct file before pressing. DO NOT turn off the power or disconnect the USB during the process. The USB update can take several minutes to complete. -
When the update is complete, the product will automatically reboot.
-
Go to the Fixture Information level of the product main menu and confirm the firmware revision.
-
When the boot-up process is finished, restart the product manually.
• Place the .chl file in the root directory of the USB drive.
• The product’s USB port supports up to 32GB capacity and only works with FAT32 file format.
Turning off the power, removing the USB, or not setting the fixture to the
correct protocol during the update can cause partial or total firmware failure
in the targeted fixture(s). Please refer to the Upload 01 Instructions to fix
firmware failure issues.
Mounting
Before mounting the product, read and follow the safety recommendations
indicated in the Safety Notes.
Orientation
Always mount this product in a safe position, making sure there is adequate
room for ventilation, configuration, and maintenance.
Rigging
Chauvet recommends using the following general guidelines when mounting this
product.
- Before deciding on a location for the product, make sure there is easy access to the product for maintenance and programming purposes.
- Make sure that the structure and attachment points can support the weight before hanging the product (see the Technical Specifications).
- When mounting the product overhead, always use a safety cable. Mount the product securely to a rigging point, whether an elevated platform or a truss.
- When rigging the product onto a truss, use a mounting clamp of appropriate weight capacity.
Procedure
The Ovation Rêve P-3 IP comes with an omega bracket. The user can directly
attach a mounting clamp (sold separately) to that bracket. Make sure the clamp
is capable of supporting the weight of this product.
For the Chauvet Professional line of mounting clamps, go to
http://www.trusst.com/products.
Mounting Diagram Changing the Lens
The Ovation Rêve P-3 IP comes with 4 interchangeable lenses with different
beam angles (Narrow, Medium, Wide, and Very Wide lenses).
To change the lens:
- Push and hold the locking tab out from the product.
- Pull the installed lens out by the flap.
- Insert the desired lens and release the locking tab.
Operation
Control Panel Description
Button | Function |
---|---|
< MENU> | Exits from the current menu or function |
< ENTER> | Enables the currently displayed menu or sets the selected value |
into the function
< UP>| Navigates upwards through the menu list or increases the numeric
value when in a function
< DOWN>| Navigates downwards through the menu list or decreases the value
when in a function
< FOCUS>| Sets fixture into Focus Mode, which takes the unit to full
power for easy focusing without changing any other fixture settings. Press
again to release from Focus Mode.
Menu Map
Refer to the Ovation Rêve P-3 IP product page on
www.chauvetprofessional.com for the
latest menu map.
Main Level | Programming Levels | Description |
---|---|---|
DMX Address | **001–512*** | Selects DMX address (*highest channel |
restricted to personality chosen)
DMX Channel| 1Ch| VCW| 1-channel: dimmer
CCT
Manual
4Ch| 4-channel: dimmer, VCW, CCT, hue
5Ch| 5-channel: RGBAL
7Ch| 7-channel: dimmer, RGBAL, strobe
11Ch| 11-channel: 16-bit dimmer, RGBAL, strobe, VCW, CCT, hue
13Ch1| 13-channel: dimmer, RGBAL, strobe, VCW, CCT, hue, auto program,
auto speed, control
13Ch2| 13-channel: 16-bit dimmer, 16-bit RGBAL, strobe
17Ch| 17-channel: 16-bit dimmer, 16-bit RGBAL, strobe, VCW, CCT, hue,
control
HSV| 3-channel: hue, saturation, value
Virtual Color| VCW| Md Yellow| Dimmer 0–255| Virtual
Color Wheel simulates the output of each gel color. Refer to the Virtual Color
Wheel Chart for specific values.
Lt Yellow
Amb Yellow
VLt Amber
Lt Amber
Md Amber
Dk Amber
Lt Red
Md Red
NC Pink
Md Pink
Dk Pink
Md Red Amber
Dk Red Amber
Magenta
Dk Magenta
Lt Lavender
Lt Blue
VLt Blue
Lt Blue 2
Main Level| Programming Levels| Description
---|---|---
Virtual Color (cont.)| VCW (cont.)| Blue| Dimmer 0–255|
Virtual Color Wheel simulates the output of each gel color. Refer to the
Virtual Color Wheel Chart for specific values.
Md Blue
Dk Blue
Indigo
VDk Blue
VDk Blue 2
Yel Green
Green
Turquoise
Aqua
Blue Green
CCT| 2800K| Dimmer 0–255 Hue – 25–25| Preset
white color temperatures. Emulates a tungsten lamp at the specified color
temperature. Refer to the Color Temperature Chart for specific values.
2900K
3000K
3100K
3200K
3300K
3400K
3500K
3600K
3700K
3800K
3900K
4000K
4100K
4200K
4300K
4400K
4500K
4600K
4700K
4800K
4900K
5000K
5100K
5200K
5300K
5400K
5500K
5600K
5700K
6000K
6500K
7000K
7500K
8000K
Main Level| Programming Levels| Description
---|---|---
Virtual Color (cont.)| Manual| Red| 0–255| Combines red,
green, blue, amber, and mint to make a custom color (0–100%)
Green
Blue
Amber
Mint
Color X-Fade Speed| Off| Disables fade transition between
colors
Fade Speed 1|
Enables fade transition between colors in the Virtual Color Wheel menu, from fast ( X-Fade Speed 1) to slow (X-Fade Speed 4)
Fade Speed 2
Fade Speed 3
Fade Speed 4
Auto Show| Auto 1–5| Speed 1–100| Selects automatic programs
and auto program speed
Red Shift| On| Mimics halogen lamp dimming
Off
Master/ Slave| Master| Receives DMX signal from the DMX controller
(master)
Slave| Receives DMX signal from the master unit
Dimmer Curve| SCurve| Sets the dimmer curve
Linear
Square
Inverse Square
Dimmer Mode| Off| Linear dimmer
Dimmer 1–3| Dimming curves, from fast ( Dimmer 1 ) to slow (
Dimmer 3 )
Color Calib| Off| Uncalibrated LED maximum values
User Calib| Red| 125–255| Sets red LED maximum value
Green| Sets green LED maximum value
Blue| Sets blue LED maximum value
Amber| Sets amber LED maximum value
Mint| Sets mint LED maximum value
Factory Calib| Uses factory default white setting
LED Frequency| 600Hz| Sets the PWM frequency
1200Hz
2000Hz
4000Hz
6000Hz
25KHz
Fan Mode| Auto| Sets the fan to auto mode
On| Sets the fan to always on
Off| Sets the fan to always off
Silent| Sets the fan to silent
Back Light| 10S| Turns off display backlight after 10 seconds
30S| Turns off display backlight after 30 seconds
2Min| Turns off display backlight after 2 minutes
Always On| Display backlight remains on
Main Level| Programming Levels| Description
---|---|---
Information| Fixture Hours| _ _Hours _ _Minute| Shows
total hours the product has been powered on
LED Hours| _ _Hours _ _Minute| Shows total hours the LEDs
have been powered on
Version| V. _| Shows current firmware version
UID| | Shows product UID
Upgrade|
Only This Fixture
| _ _.CHL| Selects an update file for this product, or shows
“ No such file! ”
…
Multiple Fixture| _ _.CHL| Selects an update file for
this and connected Ovation Rêve P-3 IP products, or shows “ No such file!
”
…
Other Fixture Type
| _ _.CHL| Selects an update file for other connected
products, or shows “ No such file! ”
…
Factory Reset| No| Resets settings to factory default
Yes
When operating in Fan Mode: Off and Fan Mode: Silent, the fixture will become
hotter to the touch than when using other fan modes. Use proper protective
equipment to prevent urns. Keep a safe distance from flammable objects.
When operating in Fan Mode: Off and Fan Mode: Silent, output of the fixture
will be reduced and will not reach the same levels as when using other fan
modes.
DMX Configuration
Use control configurations to operate the product with a DMX controller.
Control Personalities
To set the control personality:
- Go to the DMX Channel main level.
- Select the desired personality, from 1 Ch, 4 Ch, 5 Ch, 7 Ch, 11 Ch, 13 Ch1, 13 Ch2, 17 Ch, or HSV.
•See the Starting Address section for the highest selectable starting address for each personality.
• Make sure that the starting addresses on the various products do not overlap due to the new personality setting.
Starting Address
Each product will respond to a unique starting address from the controller.
All products with the same starting address will respond in unison. To set the
starting address:
- Go to the DMX Address main level.
- Select the starting address (001–512).
The highest available starting address for each DMX mode is as follows:
Personality | Address |
---|---|
1 Ch | 512 |
4 Ch | 509 |
5 Ch | 508 |
7 Ch | 506 |
11 Ch | 502 |
Personality | Address |
--- | --- |
13 Ch1 | 500 |
13 Ch2 | 500 |
17 Ch | 496 |
HSV | 510 |
Virtual Color Wheel
The Ovation Rêve P-3 IP includes a feature called the Virtual Color Wheel
(VCW). This feature is available as a standalone control mode for manual use
and as a control channel in select DMX personalities. More than 30 premixed
colors, custom blended by Chauvet engineers, are available to call up for
easier programming.
The DMX values used to mix these colors are provided below. The overall
intensity of the Ovation fixture can be adjusted to more closely replicate
familiar industry-standard colors. A chart is available at
www.chauvetprofessional.com to compare
Chauvet’s premixed colors with popular gel colors. This chart is for
comparison purposes only and is not an assertion that Chauvet’s premixed
colors match any of the gel colors listed.
Virtual Color Wheel Chart
DMX Value| Display Readout| Red| Green| Blue|
Amber| Mint
---|---|---|---|---|---|---
000 ó 005| – –| —| —| —| —| —
006 ó 013| Md Yellow| 255| 225| 000| 255| 037
014 ó 021| Lt Yellow| 255| 177| 003| 255| 037
022 ó 028| Amb Yellow| 255| 220| 000| 255| 000
029 ó 035| VLt Amber| 195| 000| 015| 255| 057
036 ó 043| Lt Amber| 255| 000| 011| 255| 061
044 ó 051| Md Amber| 255| 053| 000| 255| 017
052 ó 059| Dk Amber| 255| 008| 000| 255| 017
060 ó 067| Lt Red| 255| 000| 003| 014| 000
068 ó 075| Md Red| 255| 000| 002| 000| 000
076 ó 083| NC Pink| 255| 075| 062| 255| 073
084 ó 091| Md Pink| 255| 075| 057| 255| 041
092 ó 099| Dk Pink| 218| 077| 057| 255| 061
100 ó 107| Md Red Amber| 255| 000| 009| 168| 000
108 ó 115| Dk Red Amber| 255| 005| 009| 036| 000
116 ó 121| Magenta| 255| 003| 062| 255| 012
122 ó 130| Dk Magenta| 255| 000| 055| 000| 000
131 ó 138| Lt Lavender| 255| 220| 093| 255| 044
139 ó 146| Lt Blue| 000| 255| 159| 112| 078
147 ó 154| VLt Blue| 000| 215| 145| 196| 065
155 ó 162| Lt Blue2| 000| 215| 132| 52| 092
163 ó 170| Blue| 000| 195| 188| 000| 019
171 ó 178| Md Blue| 000| 163| 190| 000| 068
179 ó 186| Dk Blue| 000| 128| 193| 000| 038
187 ó 194| Indigo| 053| 009| 255| 000| 000
195 ó 202| VDk Blue| 007| 084| 116| 000| 000
203 ó 210| VDk Blue2| 011| 082| 139| 000| 000
211 ó 218| Yel Green| 000| 255| 002| 025| 000
219 ó 226| Green| 000| 255| 009| 000| 175
227 ó 234| Turquoise| 000| 255| 087| 096| 255
235 ó 242| Aqua| 000| 255| 098| 044| 255
243 ó 250| Blue Green| 000| 255| 026| 008| 000
251 ó 255| – –| —| —| —| —| —
The colors above are simulated renditions of the color output produced
compared with other similar incandescent products. Chauvet makes no guarantee
of the color output accuracy.
Color Temperature Chart
DMX Value| Color Temperature| Red| Green| Blue|
Amber| Mint
---|---|---|---|---|---|---
000 ó 005| No function| | | | |
006| 2800K| 253| 000| 025| 255| 145
007 ó 012| 2801–2899K| | | | |
013| 2900K| 253| 003| 028| 255| 153
014 ó 019| 2901–2999K| | | | |
020| 3000K| 251| 005| 033| 255| 161
021 ó 026| 3001–3099K| | | | |
027| 3100K| 248| 007| 036| 255| 169
028 ó 033| 3101–3199K| | | | |
034| 3200K| 245| 009| 045| 255| 173
035 ó 040| 3201–3299K| | | | |
041| 3300K| 242| 013| 047| 255| 182
042 ó 047| 3301–3399K| | | | |
048| 3400K| 237| 022| 053| 255| 185
049 ó 054| 3401–3499K| | | | |
055| 3500K| 230| 030| 058| 255| 185
056 ó 061| 3501–3599K| | | | |
062| 3600K| 225| 040| 064| 255| 185
063 ó 068| 3601–3699K| | | | |
069| 3700K| 221| 048| 070| 255| 185
070 ó 075| 3701–3799K| | | | |
076| 3800K| 220| 048| 074| 255| 197
077 ó 082| 3801–3899K| | | | |
083| 3900K| 220| 050| 079| 255| 203
084 ó 089| 3901–3999K| | | | |
090| 4000K| 210| 058| 084| 255| 203
091 ó 096| 4001–4099K| | | | |
097| 4100K| 205| 063| 088| 255| 203
098 ó 103| 4101–4199K| | | | |
104| 4200K| 199| 068| 095| 255| 204
105 ó 110| 4201–4299K| | | | |
111| 4300K| 189| 069| 098| 255| 204
112 ó 117| 4301–4399K| | | | |
118| 4400K| 183| 071| 103| 255| 204
119 ó 124| 4401–4499K| | | | |
125| 4500K| 174| 078| 107| 255| 204
126 ó 131| 4501–4599K| | | | |
132| 4600K| 170| 080| 112| 255| 204
133 ó 138| 4601–4699K| | | | |
139| 4700K| 166| 089| 119| 255| 204
140 ó 145| 4701–4799K| | | | |
146| 4800K| 164| 098| 123| 255| 203
147 ó 152| 4801–4899K| | | | |
153| 4900K| 163| 100| 129| 255| 205
154 ó 159| 4901–4999K| | | | |
160| 5000K| 163| 103| 137| 255| 206
DMX Value| Color Temperature| Red| Green| Blue|
Amber| Mint
---|---|---|---|---|---|---
161 ó 166| 5001–5099K| | | | |
167| 5100K| 163| 108| 142| 255| 208
168 ó 173| 5101–5199K| | | | |
174| 5200K| 163| 116| 147| 255| 208
175 ó 180| 5201–5299K| | | | |
181| 5300K| 163| 118| 156| 255| 210
182 ó 187| 5301–5399K| | | | |
188| 5400K| 162| 122| 162| 255| 216
189 ó 194| 5401–5499K| | | | |
195| 5500K| 162| 124| 166| 255| 224
196 ó 201| 5501–5599K| | | | |
202| 5600K| 162| 127| 172| 255| 229
203 ó 208| 5601–5699K| | | | |
209| 5700K| 159| 127| 177| 255| 231
210 ó 215| 5701–5999| | | | |
216| 6000K| 158| 134| 192| 241| 231
217 ó 222| 6001–6499K| | | | |
223| 6500K| 152| 152| 206| 225| 231
224 ó 229| 6501–6999K| | | | |
230| 7000K| 144| 157| 224| 218| 231
231 ó 236| 7001–7499K| | | | |
237| 7500K| 127| 172| 238| 218| 231
238 ó 243| 7501–7999K| | | | |
244 ó 255| 8000K| 122| 175| 255| 200| 231
The color temperatures above are simulated renditions of the color output
produced compared with a tungsten lamp at the specified color temperature.
Chauvet makes no guarantee of the color output accuracy.
Control Channel Assignments and Values
7 Ch / 13 Ch2 / 13 Ch1 / 11 Ch / 7 Ch / 5 Ch / 4 Ch
4| 5| 7| 11| 13- 1| 13- 2| 17|
Function| Value| Percent/Setting
---|---|---|---|---|---|---|---|---|---
1| –| 1| 1| 1| 1| 1| Dimmer| 000 ó
255| 0–100%
–| –| –| 2| –| 2| 2| Dimmer fine| 000
ó 255| 0–100%
–| 1| 2| 3| 2| 3| 3| Red| 000 ó 255|
0–100%
–| –| –| –| –| 4| 4| Red fine| 000 ó
255| 0–100%
–| 2| 3| 4| 3| 5| 5| Green| 000 ó
255| 0–100%
–| –| –| –| –| 6| 6| Green fine| 000
ó 255| 0–100%
–| 3| 4| 5| 4| 7| 7| Blue| 000 ó 255|
0–100%
–| –| –| –| –| 8| 8| Blue fine| 000 ó
255| 0–100%
–| 4| 5| 6| 5| 9| 9| Amber| 000 ó
255| 0–100%
–| –| –| –| –| 10| 10| Amber fine|
000 ó 255| 0–100%
–| 5| 6| 7| 6| 11| 11| Mint| 000 ó
255| 0–100%
–| –| –| –| –| 12| 12| Mint fine| 000
ó 255| 0–100%
–| –| 7| 8| 7| 13| 13| Strobe| 000 ó
010
011 ó 255| No function
Strobe, slow to fast
2| –| –| 9| 8| –| 14| Virtual color
wheel| 000 ó 255| See Virtual Color Wheel Chart
4| 5| 7| 11| 13- 1| 13- 2| 17|
Function| Value| Percent/Setting
---|---|---|---|---|---|---|---|---|---
3| –| –| 10| 9| –| 15| Color
temperature| 000 ó 255| See Color Temperature Chart
4| –| –| 11| 10| –| 16| Hue| 000
001 ó 255| 0
-25–25
**–| ****–| ****–| ****–| ****11| ****–|
****–| ****Auto programs| 000 010
011 059
060 109
110 159
160 209
210 255| No function Auto program 1
Auto program 2
Auto program 3
Auto program 4
Auto program 5
–| –| –| –| 12| –| –| Auto speed| 000
255| Auto speed, slow to fast
****–| ****–| ****–| ****–| ****13| ****–|
****17| ****Control** (hold for 3 seconds)| 000 007
008 015
016 023
024 031
032 039
040 047
048 055
056 063
064 071
072 079
080 087
088 095
096 103
104 111
112 119
120 127
128 255| No function Dimmer reset Red shift on Red shift off S-curve dimmer
Linear dimmer Square dimmer curve Inverse square dimmer curve Dimmer speed
mode: OFF Dimmer speed 1 (fastest) Dimmer speed 2 Dimmer speed 3 (slowest) Fan
auto Fan on Fan off Fan silent Reserved for future use
HSV
Channel | Function | Value | Percent/Setting |
---|---|---|---|
1 | Dimmer | 000 255 | 0–100% |
2 | Saturation | 000 255 | 0–100% |
3 | Value | 000 255 | 0–100% |
1 Ch
Channel | Function | Value | Percent/Setting |
---|---|---|---|
1 | Dimmer | 000 255 | 0–100% (color set through display menu) |
Standalone Configuration
Static Mode
The static mode options under VCW (Virtual Color Wheel) also include preset
color temperatures and a manual color mixer.
Virtual Color Wheel
To select from the Virtual Color Wheel:
- Go to the VCW main level.
- Select the VCW option.
- Select the desired virtual gel color (see the Virtual Color Wheel Chart).
- Set the Dimmer value (0–255).
Color Temperature
To select a preset color temperature:
- Go to the VCW main level.
- Select the CCT option.
- Select the desired color temperature (see the Color Temperature Chart).
- Set the Dimmer value (0–255).
- If desired, set the Hue value (-25–25).
Manual Color Mixer
To manually mix a custom static color:
- Go to the VCW main level.
- Select the Manual option.
- Select the color to edit (Red, Green, Blue, Amber, or Mint).
- Set the value for the selected color (0–255).
- Repeat steps 3 and 4 until product outputs as desired.
Color X-Fade Speed
The Color X-Fade Speed option creates a fade transition between colors when
using colors in the Virtual
Color Wheel or the Color Temperature chart.
- Go to the VCW main level.
- Select Color X-Fade Speed.
- Select Fade Speed 1–4 (from fast to slow) or Off (to turn off the fade transition between colors).
Auto Show
To select an automatic program:
- Go to the Auto Show main level.
- Select the desired auto program (Auto 1–5).
- Set the Speed value (1–100).
Configuration Settings
Red Shift
The Red Shift function imitates the dimming of a halogen lamp. To toggle Red
Shift:
- Go to the Red Shift main level.
- Select On or Off.
Master/Slave
The Master/Slave mode allows a group of Ovation Rêve P-3 IP products (the
slaves) to simultaneously duplicate the output of another Ovation Rêve P-3 IP
(the master) without a DMX controller.
To set each of the slaves:
- Go to the Master/Slave main level
- Select Slave.
To set the master:
- Go to the Master/Slave main level
- Select Master.
- Select a standalone setting.
• The master is the one that runs a program whether in Auto or Static mode.
• Do not connect a DMX controller to the products configured for Master/Slave operation. The DMX controller may interfere with signals from the master.
• The master should be the first product in the daisy chain.
Dimmer Curve
To set the dimmer curve:
- Go to the Dimmer Curve main level.
- Select the desired option (SCurve, Linear, Square, or Inverse Square).
Dimmer Profile
This setting determines how fast the output of the Ovation Rêve P-3 IP
changes when the output value is modified. It provides four different options
to simulate the dimming curve of an incandescent lighting product. To select a
specific dimmer profile, do the following:
- Go to the Dimmer Mode main level.
- Select a dimmer curve (Off, Dimmer 1, Dimmer 2, or Dimmer 3).
Off: The output is proportional (linear) to the dimmer channel value.
Dimmer 1–3: The output follows the dimmer value based on the corresponding
dimmer curve, Dimmer 1 being the fastest.
Color Calibration
This setting determines the maximum output values for each color, which
affects the appearance of the total color output.
- Go to the Color Calib main level.
- Select Off (LED values will be linear/uncalibrated), User Calib, or Factory Calib.
- For User Calib mode, select the color value to edit (Red, Green, Blue, Amber, or Mint).
- Set the maximum value for the selected color (125–255).
- Repeat steps 3 and 4 until the product outputs as desired.
Pulse Width Modulation
To set the Pulse Width Modulation (PWM) frequency of the LEDs on the Ovation
Rêve P-3 IP:
- Go to the LED Frequency main level.
- Select the PWM Frequency (600Hz, 1200Hz, 2000Hz, 4000Hz, 6000Hz, or 25Khz).
Fan Mode
To set the fan speed mode:
- Go to the Fan Speed main level.
- Select Auto (fan speed will increase or decrease based on product temperature), Off (fan will stay off. Product output will decrease based on product temperature), Silent (fan will maintain a constant silent speed), or On (fan speed will always be at maximum).
When operating in Fan Mode: Off and Fan Mode: Silent, the fixture will become
hotter to the touch than when using other fan modes. Use proper protective
equipment to prevent burns. Keep a safe distance from flammable objects.
When operating in Fan Mode: Off and Fan Mode: Silent, output of the fixture
will be reduced and will not reach the same levels as when using other fan
modes.
Display Backlight Timer
To set the amount of time the backlight on the Ovation Rêve P-3 IP’s display
stays on after the last button is pressed on the control panel:
- Go to the Back Light main level.
- Select 10S (10 seconds), 30S (30 seconds), 2Min (2 minutes), or Always On (remains on).
Information
To view essential product information:
- Go to the Information main level.
- Select Fixture Hours, LED Hours, Version, or UID.
Factory Reset
To reset the product to factory settings:
- Go to the Factory Reset main level.
- Select No (to cancel) or Yes (to reset the product configuration).
. Maintenance
Product Maintenance
Dust build-up reduces light output performance and can cause overheating. This
can lead to reduction of the light source’s life and/or mechanical wear. To
maintain optimum performance and minimize wear, clean each lighting product at
least twice a month. However, be aware that usage and environmental conditions
could be contributing factors to increase the cleaning frequency.
To clean the product, follow the instructions below:
- Unplug the product from power.
- Wait until the product is at room temperature.
- Use a vacuum (or dry compressed air) and a soft brush to remove dust collected on the external surface/vents.
- Clean all transparent surfaces with a mild soap solution, ammonia-free glass cleaner, or isopropyl alcohol.
- Apply the solution directly to a soft, lint free cotton cloth or a lens cleaning tissue.
- Softly drag any dirt or grime to the outside of the transparent surface.
- Gently polish the transparent surfaces until they are free of haze and lint.
Always dry the transparent surfaces carefully after cleaning them.
Torque Measurements
To maintain the IP rating when reassembling the product, use the given torque
measurements for each of the following screws and bolts:
Fixture Parts| Torque Rating (Kgf.cm)| Torque Rating
(lgb.in)
---|---|---
USB and DMX Connectors| 6.5| 5.64
Power Connectors| 3.5| 3.04
Covers| 9.5| 8.25
Vacuum Test Measurements
To ensure that the product has been reassembled correctly, use the IP Tester
from Chauvet Professional to check the following data has the given
measurements for the given method:
Parameters | Values |
---|---|
Method | Positive |
Test pressure | 4-5 kPa |
Test duration | 15 seconds |
PASS state leak pressure | <0.01 kPa |
Technical Specifications
Dimensions and Weight
Length | Width | Height | Weight |
---|---|---|---|
18.82 in (478 mm) | 11.81 in (300 mm) | 8.27 in (210 mm) | 21.4 lb (9.8 kg) |
Note: Dimensions in inches are rounded.
Power
Power Supply Type | Range | Voltage Selection |
---|---|---|
Switching (internal) | 100 to 240 VAC, 50/60 Hz | Auto-ranging |
Parameter | 100 V, 60 Hz | 120 V, 60 Hz |
230 V, 50 Hz | 240 V, 50 Hz | |
Consumption | 275 W | 274 W |
Operating Current | 2.78 A | 2.31 A |
Max. Output Current | 13.6 A | 13.6 A |
Fuse | T 6.3 A, 250 V | T 6.3 A, 250 V |
250 V
Power I/O| U.S./Worldwide| UK/Europe
Power Input Connector| Seetronic Powerkon IP65| Seetronic Powerkon IP65
Power Output Connector| Seetronic Powerkon IP65| Seetronic Powerkon IP65
Power Cable plug| Edison| Local plug
Light Source| | | | |
Type| Color| Quantity| Power| Current| Lifespan
| Red| 10| | |
| Green| 10| | |
LED| Blue| 10| 4.4 to 7.8 W| 2.4 A| 50,000 hours
| Amber| 20| | |
| Mint| 30| | |
Photometrics| | | | |
Lens| Beam Angle| Field Angle| Illuminance @ 5 m
Narrow| 11.9°| 20.8°| 6.910 lux
Medium| 25.6°| 37.8°| 1,950 lux
Wide| 29.3°| 43.1°| 1,475 lux
Very Wide| 43.5°| 87.9°| 401 lux
Thermal| | | | |
Maximum External Temperature| Cooling System
---|---
113 °F (45 °C)| Fan-assisted Convection
Control
DMX I/O Connector | Channel Range |
---|---|
3-pin XLR, 5-pin XLR | 1, 4, 5, 7, 11, 13ch1, 13ch2, 17 or HSV |
Ordering
Product Name | Item Name | Item Code | UPC Number |
---|---|---|---|
OvationRêveP-3 IP | OVATIONREVEP3IP | 1031928 | 7.81462E+11 |
Contact Us
General Information | Technical Support |
---|
Chauvet World Headquarters
Address: 3360 Davie Rd., Suite 509
Davie, FL 33314
Voice: 954-577-4455
Fax: 954-929-5560
Toll Free: 800-762-1084| Voice:
844-393-7575
Fax: 954-756-8015
Email: chauvetcs@chauvetlighting.com
Website: www.chauvetprofessional.com
Chauvet U.K.|
Address: Pod 1 EVO Park
Little Oak Drive, Sherwood Park
Nottinghamshire, NG15 0EB Website:
UK
Voice: +44 (0) 1773 511115
Fax: +44 (0) 1773 511110| Email:
UKtech@chauvetlighting.eu
Website: www.chauvetprofessional.eu
Warranty & Returns
For warranty terms and conditions and return information, please visit our
website.
For customers in the United States and Mexico: www.chauvetlighting.com
/warranty-registration.
For customers in the United Kingdom, Republic of Ireland, Belgium, the
Netherlands, Luxembourg,
France, and Germany: www.chauvetlighting.eu/warranty-
registration.
Ovation Rêve P-3 IP User Manual Rev. 4
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>