BEGA 50213.4 Luminaire v/t LED Instructions

June 13, 2024
BEGA

50 213.4
Wall luminaire for indoor use
Instructions for use

50213.4 Luminaire v/t LED

BEGA 50213.4 Luminaire v t LED - Fig1

Application

Wall luminaire · indoor luminaire with velvet black luminaire housing and inside hue.
The light emits upwards and downwards.

Product description

Wall luminaire “STUDIO LINE” Aluminium luminaire housing, Colour velvet black finish, Inside hue matt brass Reflector made of pure anodized aluminium 2 elongated fixing holes
Width 4.5 mm · 90 x 38 mm spacing 1 cable entry for through-wiring for mains cable
Connecting terminal 2.5@ with plug connection
Earth conductor connection
LED-Module for mains voltage 220-230 V ** 50/60 Hz
BEGA Thermal Switch®
Temporary thermal shutdown to protect temperature-sensitive components
Safety class I
– Safety mark
– Conformity mark
Weight:** 0.65 kg

Safety

The installation and operation of this luminaire are subject to national safety regulations.
Installation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation.
If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.

Lamp

Luminaire connected wattage| 10 W
Rated temperature| ta = 25 °C
Ambient temperature| ta max = 40 °C
50 213.4 K3
Module designation| LED-0607/930
Colour temperature| 3000 K
Colour rendering index| Ra > 90
Module luminous flux| 940 lm
Luminaire luminous flux| 249 lm
Luminaire luminous efficiency| 24,9 lm / W

Installation

LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during installation or revamping.
Undo set screw and lift off luminaire housing.
Loosen LED-connection and earth connection (plug connection).
Pass the power connecting cable through the cable entry in the mounting plate. Note position of application of the luminaire “arrow down”.
Fasten the mounting plate with the supplied fastening material or other suitable fastening material to the installation surface.
Make earth conductor connection.
Push silicone sleeves over the lines and make electrical connection to terminal (plug connection).
Make earth conductor connection between luminaire housing and mounting plate.
Push LED plug into coupler as fa as it will go.
Install luminaire housing over mounting plate and tighten set screw.

Cleaning · Maintenance

Clean luminaire regularly with solvent-free cleansers from dirt.
Replacement of the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
The module can be replaced by qualified persons using standard tools.
Disconnect the system and open the luminaire.
Please follow the installation instructions for the LED module.
Defective glass must be replaced.
Close the luminaire.

Spares

LED module 3000 K| LED-0607/930

Technical amendments reserve