UNI BRIGHT MN24018WDD Led Surface Mounted Ceiling Light Instruction Manual

June 13, 2024
UNI-BRIGHT

Moon 240 DALI/PUSH
INSTALLATION MANUAL

MN24018WDD White ø245 mm SMD LED 18W 3000 K 1800Lm
MN24018WBDD Black ø245 mm SMD LED 18W 3000 K 1800Lm

Dali/ Push dimmable

UNI BRIGHT MN24018WDD Led Surface Mounted Ceiling Light -
ICON

Warning

  • WARNING!
    To prevent electrical shock – Always switch off electricity supply before installation and maintenance.

Installation

Surge

UNI BRIGHT MN24018WDD Led Surface Mounted Ceiling Light -
Table

Remarks

  • The number of drives mounted under different MCBs in the table is the maximum value. Please do not exceed this number during installation.
  • Calculation uses typical values from ABB series S200 asa reference.
  • Different brands and models of miniature circuit breakers, the number of drives mounted will be slightly different.
  • if the ambient temperature of the MCB installation exceeds 30°C or multiple MCBs are installed side by side, the number of drives mounted will be reduced and the calculation needs to be recalculated.
  • Electrician’s usually consider Type B for household lighting and Type C for commercial lighting application.

UNI BRIGHT MN24018WDD Led Surface Mounted Ceiling Light -
Remarks

Functions
Output short-circuit behaviour

  • Incase of a short-circuit at the LED output ,the LED output is switched off.
  • After restart of the LED driver ,the output will be activated again.

Output no-load operation

  • The LED driver will not be damaged in no-load operation.
  • The output will be deactivated and is therefore free of voltage.
  • If a LED load is connected , the device has to be restarted before the output will be activated again.

Output overload protection
In the following two cases,the LED driver will automatically turn off the output to protect the LED

  • When the driver is powered on first and the LED is connected later.
  • When the driver is powered on,disconnected and connecred again.
  • After restart of the LED driver the output will be activated again.

Driver restart method
There are two ways to restart the device:

  • Through the AC input portr:disconnect the AC of the driver and power it again.
  • Through dimming interface.

DALI:send“OFF”’command first,then send “MAX”command.
pushDIM:short press PUSH switch two times,then long press PUSH switch.

DALI dimming application
Wiring diagram

UNI BRIGHT MN24018WDD Led Surface Mounted Ceiling Light - Wiring
Diagram

Activating DALI dimming mode

  • After installation according to the wiring diagram of DALI dimming application,the driver will automatically switch to the DALI control mode afterreceiving any DALI command.

Activating DALI dimming mode

  • After installation according to the wiring diagram of DALI dimming application,the driver will automatically switch to the DALI control mode after receiving any DALI command.

Remarks:

  • Standard DALI control line voltage range:9.5V to 22.5V ,type 16V.
  • The two DALI control lines polarity-reversible.
  • Max. 64 DALI drivers per DALI control line.
  • The maximum distance length of the DALI control line is 300m at 2×1.5mm2.
  • DALI bus can be wired together with any mains voltage cables, but separate wiring is recommended.
  • The configuration parameters of the driver can be set through the DALI configuration tool or DALI application controller during installation, such as setting device address, group address, power-on level, bus- failure level, scene level, fade time, dimming curve, etc.

Power-on level :
When the driver is in DALI-2 dimming mode, the factory default level after each power-on is the brightest. The power-on level can be set through the DALI configuration tool or DALI application controller during installation, and can be set to memory or fixed any brightness (such as off, darkest,50%, etc.).
Note: The recommended setting for the default factory power-on level of the DALI-2 driver is the brightest in the DALI-2 standard.

pushDIM dimming application
Wiring diagram

UNI BRIGHT MN24018WDD Led Surface Mounted Ceiling Light - Wiring Diagram
2

Activating pushDIM dimming mode
After installation according to the wiring diagram of pushDIIM dimming application, short press the pushbuttom 3 times within 3 seconds, the driver will automatically switch to pushDIIM dimming mode.
Remarks:
Max. 50 drivers per pushDIM control line.
Turn on or turn off:short press pushbuttom for 0.2-1s.
Dimming: long press pushbuttom for 1-5s.
Power on status: after power on,the light state will be the same as the lighting on state.
If the light is on before power on,the light will be on after power on again, brightness will be the same as the last lighting on brightness.
If the light is off before power off,the light will be off after power on again,short press the pushbuttom,then the light will be on,the brightness will be the same as the last brightness.

UNI BRIGHT MN24018WDD Led Surface Mounted Ceiling Light - Wiring Diagram
3

Multiple lights synchronize control operation
method 1 :
Step 1:long press the pushbuttom,confirm each light is on.
Step 2:short press the pushbuttom,confirm each light is off.
Step 3:long press the pushbuttom,confirm each light is from darkest to brightest and all the lights are synchronous.
– Long press the pushbuttom 15s,all lights output to the brightest state.

Please follow the sequence of installation step by step

  1. Install back of the fixture to ceiling or wall and connect wires. UNI BRIGHT MN24018WDD Led Surface Mounted Ceiling Light - Montage
  2. Prepare 3 holes and install screw anchors.
  3. Put the cover back on the fixure.UNI BRIGHT MN24018WDD Led Surface Mounted Ceiling Light - Montage 2

Safety

  • For indoor use only. ;
    This fitting should only be installed in rooms where direct contact with water is impossible.

  • Luminaire not suitable for covering with insulating material.

  • IP54
    Limited protection against dust ingress. Protected against splash water from any direction

  • Correct disposal of this product (electrical & electronical equipment waste)

  • The electrical installation should be carried out by qualified personal only, according to the regulations for electrical and mechanical safety in your country. Improper installation can result in serious injuries and/or damage to property.

This product contains a light source of energy efficiency class

UNI-BRIGHT nv
Belcrownlaan 13-Q
2100 Antwerpen Belgium
T+32(0)3 6416140
F +32(0)3
6451831
www.unibright.be

Documents / Resources

| UNI BRIGHT MN24018WDD Led Surface Mounted Ceiling Light [pdf] Instruction Manual
MN24018WDD Led Surface Mounted Ceiling Light, MN24018WDD, Led Surface Mounted Ceiling Light, Mounted Ceiling Light, Ceiling Light
---|---

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals