Product Information

The 45W AC-DC PCB-Mount Green Power Module is a power module from the IRM-45 series. It is a low power supply (LPS) that meets UL62368-1 safety standards. It is also certified by Bauar t gepruft Sicherheit, egelma ge od o s be wac g, and TUV BS EN/EN62368-1 BS EN/EN60335-1. The model is available in five different variants:
IRM-45-5, IRM-45-12, IRM-45-15, IRM-45-24, and IRM-45-48.

Specifications

Model| Output DC Voltage| Rated Current| Current Range| Rated Power| Ripple & Noise (max.)| Line Regulation| Load Regulation| Setup, Rise Time| Hold Up Time (Typ.)| Voltage Range| Frequency Range
---|---|---|---|---|---|---|---|---|---|---|---
IRM-45-5| 5V| 8A| 0 ~ 8A| 40W| 80mVp-p| N/A| N/A| 1000ms, 30ms/230VAC 2000ms, 30ms/115VAC at full load| 50ms/230VAC 12ms/115VAC at full load| 85 ~ 305VAC| 47 ~ 440Hz
IRM-45-12| 12V| 3.8A| 0 ~ 3.8A| 45.6W| 150mVp-p| N/A| N/A| 1000ms, 30ms/230VAC 2000ms, 30ms/115VAC at full load| 50ms/230VAC 12ms/115VAC at full load| 85 ~ 305VAC| 47 ~ 440Hz
IRM-45-15| 15V| 3A| 0 ~ 3A| 45W| 180mVp-p| N/A| N/A| 1000ms, 30ms/230VAC 2000ms, 30ms/115VAC at full load| 50ms/230VAC 12ms/115VAC at full load| 85 ~ 305VAC| 47 ~ 440Hz
IRM-45-24| N/A| N/A| N/A| N/A| N/A| N/A| N/A| N/A| N/A| N/A| N/A
IRM-45-48| 48V| 0.94A| 0 ~ 0.94A| 45.12W| 120mVp-p| N/A| N/A| 1000ms, 30ms/230VAC 2000ms, 30ms/115VAC at full load| 50ms/230VAC 12ms/115VAC at full load| 85 ~ 305VAC| 47 ~ 440Hz

Product Usage Instructions

To use the 45W AC-DC PCB-Mount Green Power Module, follow these instructions:

  1. Select the appropriate model variant based on your desired output DC voltage and rated power.
  2. Ensure that the input voltage range (85 ~ 305VAC) and frequency range (47 ~ 440Hz) match your power supply requirements.
  3. Connect the power module to the input power source using appropriate wiring connections.
  4. Make sure to observe the working temperature range (-30 ~ +70) and working humidity range (20 ~ 90% RH non-condensing).
  5. Ensure proper ventilation and cooling for the power module to prevent overheating.
  6. Check the safety standards and certifications of the power module to ensure compliance with relevant regulations.
  7. Follow proper soldering temperature and duration guidelines if soldering the power module.
  8. Monitor the output voltage, current, and power to ensure they are within the specified ranges for safe and efficient operation.
  9. Take necessary precautions for EMC immunity and emission as per the provided standards and test levels.
  10. Refer to the product manual for additional information and troubleshooting guidance.

45W AC-DC PCB-Mount Green Power Module

Features

  • 3.43″×2.05″compact size
  • PCB,chassis or screw terminal mounting version
  • Universal input 85~305VAC
  • No load power consumption<0.15W
  • EMI Class B without additional components
  • Wide operating temp. range -30~70 C
  • Protections: Short circuit / Overload / Over voltage
  • Cooling by free air convection
  • Isolation Class II
  • Over voltage category III
  • Pass LPS(Except for 5V)
  • 3 years warranty

Applications

  • Industrial electrical equipment
  • Mechanical equipment
  • Factory automation equipment
  • Handheld electronic device

GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx

Description

IRM-45 is a 45W miniature (875229.5mm) AC-DC module-type power supply, ready to be soldered onto the PCB boards of various kinds of electronic instruments or industrial automation equipments. This product allows the universal input voltage range of 85~305VAC. The 94V-0 flame retardant plastic case and the fully-potted silicone enhance the heat dissipation. PB mounting style model(Blank) meet the anti-vibration demand up to 2G and screw terminal style model (ST) meet the anti-vibration demand up to 5G; moreover, it provides the fundamental resistance to dust and moisture.
With the high efficiency up to 90.5% and the extremely low no-load power consumption below 0. 15W, IRM-45 series fulfills the worldwide regulation for the low power consumption requirement for electronics. The entire series is a Class II design (no FG pin), incorporating the built-in EMI filtering components, enabling the compliance with BS EN/EN55032 Class B; the supreme EMC features keep the end electronic units from electromagnetic interference. In addition to the PCB mounting style model, IRM-45 series also offers the screw terminal style model (ST).

Model Encoding

MEAN WELL-IRM-45-5-AC-DC-PCB-Mount-Green-Power-
Module-3

SPECIFICATION

MODEL| IRM-45-5| IRM-45-12| IRM-45-15| IRM-45-24| IRM-45-48
---|---|---|---|---|---






OUTPUT

| DC VOLTAGE| 5V| 12V| 15V| 24V| 48V
RATED CURRENT| 8A| 3.8A| 3A| 1.9A| 0.94A
CURRENT RANGE| 0 ~ 8A| 0 ~ 3.8A| 0 ~ 3A| 0 ~ 1.9A| 0 ~ 0.94A
RATED POWER| 40W| 45.6W| 45W| 45.6W| 45.12W
RIPPLE & NOISE (max.) **Note.2| 80mVp-p| 150mVp-p| 180mVp-p| 200mVp-p| 300mVp-p
VOLTAGE TOLERANCE Note.3| ±2.5%| ±2.5%| ±2.5%| ±2.5%| ±2.5%
LINE REGULATION| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
LOAD REGULATION| ±1.0%| ±1.0%| ±0.5%| ±0.5%| ±0.5%
SETUP, RISE TIME| 1000ms, 30ms/230VAC              2000ms, 30ms/115VAC at full load
HOLD UP TIME (Typ.)**| 50ms/230VAC              12ms/115VAC at full load




INPUT

| VOLTAGE RANGE| 85 ~ 305VAC
FREQUENCY RANGE| 47 ~ 440Hz
EFFICIENCY (Typ.)| 83.5%| 87.5%| 88.5%| 89.5%| 90.5%
AC CURRENT (Typ.)| 1.5A/115VAC          0.9A/230VAC 0.75A/277VAC
INRUSH CURRENT (Typ.)| COLD START 30A/115VAC             60A/230VAC
LEAKAGE CURRENT| < 0.25mA/277VAC



PROTECTION

| OVERLOAD| 115%~160% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed


OVER VOLTAGE

| 5.25 ~ 6.75V| 12.6 ~ 16.2V| 15.75 ~ 20.25V| 25.2 ~ 32.4V| 50.4 ~ 64.8V
Protection type : Shut off o/p voltage, clamping by zener diode




ENVIRONMENT

| WORKING TEMP.| -30 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 50℃)
VIBRATION| Blank:10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
ST:10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes
SOLDERING TEMPERATURE| Wave soldering: 265℃,5s (max.); Manual soldering: 390℃,3s (max.)
OVER VOLTAGE CATEGORY| Ⅲ; According to EN62368-1;altitude up to 2000 meters
OPERATING ALTITUDE Note.4| 2000 meters








SAFETY & EMC

(Note.5)

| SAFETY STANDARDS| IEC62368-1, UL62368-1, TUV BS EN/EN62368-1, BS EN/EN60335-1, EAC TP TC 004, BSMI CNS14336-1 approved
WITHSTAND VOLTAGE| I/P-O/P:4KVAC
ISOLATION RESISTANCE| I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH



EMC EMISSION

| Parameter| Standard| Test Level / Note
Conducted| BS EN/EN55032(CISPR32), CNS13438| Class B
Radiated| BS EN/EN55032(CISPR32), CNS13438| Class B
Harmonic Current (Note 5)| BS EN/EN61000-3-2| Class A
Voltage Flicker| BS EN/EN61000-3-3| ——-





EMC IMMUNITY

| BS EN/EN55035, BS EN/EN61000-6-2
Parameter| Standard| Test Level /Note
ESD| BS EN/EN61000-4-2| Level 3, 8KV air; Level 2, 4KV contact, criteria A
Radiated Susceptibility| BS EN/EN61000-4-3| Level 3, criteria A
EFT/Burest| BS EN/EN61000-4-4| Level 3, criteria A
Surge| BS EN/EN61000-4-5| Level 4, 2KV/L-N, criteria A
Conducted| BS EN/EN61000-4-6| Level 3, criteria A
Magnetic Field| BS EN/EN61000-4-8| Level 4, criteria A
Voltage Dips and interruptions| BS EN/EN61000-4-11| >95% dip 0.5 periods, 30% dip 25 periods,

>95% interruptions 250 periods


OTHERS

| MTBF| 6451.1K hrs min.        Telcordia SR-332 (Bellcore) ; 1212.1K hrs min.         MIL-HDBK-217F (25℃)
DIMENSION| PCB mounting style : 875229.5mm (LWH)              Screw terminal style : 1095233.5mm (LWH)
PACKING| PCB  mounting style : 0.195Kg;60pcs/12.7Kg/0.94CUFT Screw terminal style :0.228Kg; 50pcs/12.4Kg/0.56CUFT
Note| 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 C of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The ambient temperature derating of 3.5°C/1000m with fanless models and of 5°C/1000m with fan models for operating altitude higher than 2000m(6500ft)
5. The power supply is considered as an independent unit ,but the final equipment still need to re-confirm that the whole system complieswith the EMC
directives. For guidance on how to perform these MC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
› Product Liability Disclaimer • For detailed information. please refer to httos://wwww.meanwell.com/serviceDisclaimer asox

Block Diagram

MEAN WELL-IRM-45-5-AC-DC-PCB-Mount-Green-Power-
Module-4

Derating Curve

MEAN WELL-IRM-45-5-AC-DC-PCB-Mount-Green-Power-
Module-5

Output Derating VS Input Voltage

Mechanical S Specification
  • PCB mounting style (IRM-45)MEAN WELL-IRM-45-5-AC-DC-PCB-Mount-Green-Power-Module-7
  • Screw terminal style (IRM-45-xxST)

MEAN WELL-IRM-45-5-AC-DC-PCB-Mount-Green-Power-
Module-8

Screw terminal style (IRM-45-xxST)