The product is an Elsa H689906 light fixture manufactured by Mitzi, a part of the Hudson Valley Lighting Group. It is designed for installation in residential or commercial buildings and requires a standard round or octagon junction box. The fixture is rated for a maximum of 60 watts and uses a Type B lamp (G16.5 recommended).

For more information, visit the manufacturer’s website at: www.hvlgroup.com.

Product Usage Instructions

  1. Feed the wire through the stem (Part L) and twist tightly onto the fixture assembly (Part N). Add additional stems as needed to achieve the desired hanging height.
  2. Attach the nipple (Part G) onto the stem (Part L), then insert the check ring (Part H) onto the nipple (Part G). Attach the canopy (Part I) on top of the stem (Part L) and secure using hex nuts (Part K) and tooth washer (Part J).
  3. Pull the wire out from the junction box and install the mounting plate (Part A) onto the junction box using the mounting screws (Part B). Thread the mounting nipple (Part C) onto the mounting plate (Part A) and adjust its threads so that 1/36 of threads extend beyond the canopy (Part I). Secure using mounting hex nuts (Part D).
  4. Trim off the excess wire to a minimum of 6 inches beyond the stem (Part L) and strip each wire 8/5 inches.
  5. Attach the ground wire (green) to the ground inside the outlet box (generally green or bare copper wire) or the ground screw (Part E) on the mounting plate (Part A). Never connect ground wire to hot wire.
  6. Connect the white fixture lead to the neutral (generally white) wire in the outlet box. Fasten the wires together with an approved fastener (wire nut) (Part F). Starting 1 inch below the fastener, tightly wrap the connection with electrical tape to seal the end of the fastener. Make sure there are no exposed wires or strands that could cause a dangerous short circuit.
  7. Connect the black fixture leads to the hot (generally black) wire in the outlet box. Fasten the joined wires same as in the previous step. Never reverse hot and neutral wires.
  8. Push the wires back into the junction box. Lift up the canopy (Part I) up to the ceiling and secure with the cap nut (Part M).
  9. Screw the bulb (Part O) into the socket of the fixture assembly (Part N). Do not exceed the recommended wattage of 60 watts for Type B lamp (G16.5 recommended).
  10. Restore power to the outlet at the breaker or fuse box.

Precautions

WARNING/CAUTION

  • DISCONNECT POWER BEFORE RE-LAMPING OR WIRING THE FIXTURE. READ ALL INSTRUCTIONS COMPLETELY BEFORE STARTING INSTALLATION.
  • TO AVOID THE RISK OF FIRE OR SHOCK, FIXTURE MUST BE INSTALLED IN COMPLIANCE WITH ALL APPLICABLE NATIONAL AND LOCAL ELECTRICAL/BUILDING CODES. THE INSTALLATION AND MAINTENANCE OF THIS UNIT SHOULD BE COMPLETED BY A LICENSED ELECTRICIAN OR CERTIFIED FACTORY TRAINED TECHNICIAN.
  • CALIFORNIA PROP 65: THIS LIGHTING FIXTURE CONTAINS CHEMICALS KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER, BIRTH DEFECTS, AND/OR OTHER REPRODUCTIVE HARM. WASH HANDS AFTER USE.
  • UNPACK FIXTURE, PARTS AND PARTS BAG(S) BEFORE DISCARDING THE CARTON. MAKE CERTAIN THAT ALL PARTS ARE FOUND. INSPECT THE FIXTURE PRIOR TO INSTALLATION FOR ANY DAMAGE. HVLG DOES NOT PAY OR REIMBURSE ELECTRICIAN FEES. FIXTURE MAY NOT BE RETURNED ONCE IT HAS BEEN INSTALLED. SEE WARRANTY FOR EXCEPTIONS.
  • PLEASE CLEAN WITH A SOFT, DRY CLOTH ONLY! DO NOT USE CLEANSERS.

FIXTURE INSTALLATION

Mitzi-H689906-GL-Six-Light-Linear-Elsa-fig-1

  1. Feed the wire through the STEM (L) and twist tightly onto the FIXTURE ASSEMBLY (N). Keep adding additional stems until your desired hanging height is met.
  2. Attach the NIPPLE (G) onto the STEM (L) then insert the CHECK RING (H) onto the NIPPLE (G). Attach the CANOPY (I) on top of the STEM (L), and secure using HEX NUTS (K) and TOOTH WASHER (J).
  3. Pull the wire out from the junction box, and install the MOUNTING PLATE (A) onto the junction box using the MOUNTING SCREWS (B). This fixture is designed to be mounted on standard round or octagon junction box. The junction box must be securely mounted to the structure of the building. Thread the MOUNTING NIPPLE (C) unto the MOUNTING PLATE (A), adjust its threads so that 3 16″ of threads extend beyond the CANOPY (I), secure using MOUNTING HEX NUTS (D).
  4. Trim off the excess wire to a minimum 6″ beyond the STEM (L) and strip each wire 58″.
  5. Attach the Ground wire (Green) to the ground inside the outlet box (Generally green or bare copper wire) or the GROUND SCREW (E) on the MOUNTING PLATE (A). NEVER CONNECT GROUND WIRE TO “HOT” WIRE. FAILURE TO FOLLOW THIS COULD RESULT IN SERIOUS INJURY OR DEATH.
  6. Connect the white fixture lead to the neutral (Generally white) wire in the outlet box. Fasten the wires together with an approved fastener (WIRE NUT) (F). Starting 1″ below the fastener, tightly wrap theconnection with electrical tape so that the connections seals the end of the fastener. MAKE SURE THERE ARE NO EXPOSED WIRE OF STRANDS THAT COULD CAUSE A DANGEROUS SHORT CIRCUIT.
  7. Connect the black fixture leads to the hot (Generally black) wire in the outlet box. Fasten the joined wires same as previous step. NEVER REVERSE HOT AND NEUTRAL WIRES. FAILURE TO FOLLOW THIS COULD RESULT IN SERIOUS INJURY OR DEATH.
  8. Push the wires back into the junction box. Lift up the CANOPY (I) up to the ceiling, and secure with the CAP NUT (M).
  9. Screw the BULB (O) into the SOCKET of the FIXTURE ASSEMBLY (N). THIS FIXTURE IS RATED FOR 60 WATTS TYPE B LAMP (G16.5 RECOMMENDED). DO NOT EXCEED THE RECOMMENDED WATTAGE.
  10. Restore power to the outlet at the breaker or fuse box.
PART(S) REPLACEMENT PART NAME NUMBER
A,B,C,D,E,F HARDWARE KIT HDW-H689906
G,H,I,J,K CANOPY ASSEMBLY CAS-H689906
M CAP NUT CPN-H689906
L STEM SET STM-TC1200-SET

www.hvlgroup.com