V-TAC VT-122 T8 LED Tube Light Instruction Manual
- June 4, 2024
- V TAC
Table of Contents
V-TAC VT-122 T8 LED Tube Light Instruction Manual
TECHNICAL DATA:
Model | VT-061 | VT-121 | VT-151 | VT-062 | VT-122 | VT-152 |
---|---|---|---|---|---|---|
Watts | 9 | 18 | 20 | 7.5 | 16.5 | 24 |
Lumens | 850 | 1850 | 2100 | 850 | 1850 | 3000 |
CRI | >80 | >80 | >80 | >80 | >80 | >80 |
DF | >0.5 | >0.7 | >0.7 | >0.5 | >0.7 | >0.7 |
BeamAngle | 160° | 160° | 160° | 160° | 160° | 160° |
Body Type | Plastic | Plastic | Plastic | Plastic | Plastic | Plastic |
Holder | G13 | G13 | G13 | G13 | G13 | G13 |
Long Life | 25,000 Hours | 25,000 Hours | 25,000 Hours | 25,000 Hours | 25,000 | |
Hours | 25,000 Hours | |||||
On/Off Cycles | >15000 | >15000 | >15000 | >15000 | >15000 | >15000 |
Dimension | 600x28mm | 1200x28mm | 1500x28mm | 600x28mm | 1200x28mm | 1500x28mm |
Input Power | AC:220-240V,50Hz | AC:220-240V,50Hz | AC:220-240V,50Hz | |||
AC:220-240V,50Hz | AC:220-240V,50Hz | AC:220-240V,50Hz |
- This marking indicates that this product should not be disposed of with other household wastes.
- LED Lamps suitable for 50Hz operation
- LED Lamps to be used in dry conditions or in a luminaire that provides protection
- Caution, risk of electric shock.
- LED Tubes are NOT suitable for dimming
- LED Tubes not suitable for emergency operations
- LED replacement starter (Included in the packaging)
INTRODUCTION & WARRANTY
Thank you for selecting and buying the V-TAC product. V-TAC will serve you the best. Please read these instructions carefully before starting the installation and keep this manual handy for future reference. If you have any other queries, please contact our dealer or local vendor from whom you have purchased the product. They are trained and ready to serve you at their best. The warranty is valid for 5 years from the date of purchase. The warranty does not apply to damage caused by incorrect installation or abnormal wear and tear. The company gives no warranty against damage to any surface due to incorrect removal and installation of the product. The products are suitable for 10-12 Hours of Daily operation. Usage of the product for 24 Hours a day would void the warranty. This product is warranted for manufacturing defects only. The LED tube can be used in hotels, offices, factories, conference rooms, meeting rooms, commercial complexes, residential buildings, schools, colleges, universities, hospitals, etc.
PACKING:
- LED Tube (1PC)
- Instruction Manual (1PC)
- Dummy Starer (1PC)
WARNINGS!
- Installation should only be done by a certified electrician
- Operation environment temperature: from -20°C to +45°C
- Do not use DC electricity
- Do not modify the fitting to be used with the LED Tube.
- V-TAC LED Tubes are NOT designed to be used in emergency operations.
- Do NOT use electronic ballasts. V-TAC LED tubes are not compatible with electronic ballast circuits. In order to use the electronic ballast fitting, you must ensure to remove the electronic ballast from the fitting and rewire the circuit as per the new fitting installation as shown below. Ensure the installation and wiring are carried out by a certified electrician.
New Fitting Installation
- Installation should only be done by a certified electrician
- Switch Off the power.
- Ensure the wiring diagram is followed as highlighted.
- Insert V-TAC LED Tube.
- Switch On the power to test the light.
Installation & Replacement of Fluorescent Lamp(Single Magnetic Ballast Circuit)
- Installation should only be done by a certified electrician.
- Please refer to the wiring diagram for replacing the fluorescent tube on a single magnetic ballast circuit with V-TAC LED Tube.
References