mitzi H711809-AGB Mimi Nine Light Chandelier Instruction Manual
- June 13, 2024
- mitzi
Table of Contents
mitzi H711809-AGB Mimi Nine Light Chandelier
Hudson Valley Lighting Group
MIMI H711809 Installation Instructions
Hudson Valley Lighting Group offers a wide range of high-quality lighting fixtures, including the MIMI H711809 model. This installation guide will provide you with detailed instructions on how to properly install and use your fixture.
Fixture Installation
- Attach the MOUNTING PLATE (A) onto the junction box using the MOUNTING SCREWS (B). Ensure that the junction box is securely mounted to the structure of the building. This fixture is designed to be mounted on standard round or octagon junction boxes.
- Open the end link on the CHAIN (I) and attach it to the loop on the FIXTURE ASSEMBLY (J). Hang the FIXTURE ASSEMBLY (J) on the CHAIN (I) at your desired height and remove any excess chain.
- Feed the wire through the CHAIN (I) , SCREW COLLAR (G) , CANOPY (H) , SCREW COLLAR LOOP (F) , NIPPLE (E) , and MOUNTING PLATE (A). Screw the NIPPLE (E) onto the MOUNTING PLATE (A).
- Open the top link on the CHAIN (I) and hang the FIXTURE ASSEMBLY (J) to the SCREW COLLAR LOOP (F).
- Cut off any excess wire and strip the insulation off the end of the leads.
- Attach the Ground wire (Green) to the ground inside the junction box (generally green or bare copper wire) or the GROUND SCREW (C) on the MOUNTING PLATE (A). NEVER CONNECT THE GROUND WIRE TO THE HOT WIRE, as failure to follow this could result in serious injury or death.
- Connect the fixture lead(s) to the neutral (generally white) wire in the outlet box. Fasten the wires together with an approved fastener (WIRE NUT) (D). Starting 1 inch below the fastener, tightly wrap the connection with electrical tape to ensure there are no exposed wires or strands that could cause a dangerous short circuit.
- Connect the smooth fixture leads to the hot (generally black) wire in the junction box. Fasten the joined wires as done in the previous step. NEVER REVERSE HOT AND NEUTRAL WIRES, as failure to follow this could result in serious injury or death.
- Push the wires back into the junction box. Lift up the CANOPY (H) up to the ceiling and secure it with the RING (G).
- Screw the BULB (K) into the SOCKET of the fixture. This fixture is rated for an 8-watt Type G16.5 lamp. DO NOT EXCEED THE RECOMMENDED WATTAGE.
- Hang the GLASS (L) on the FIXTURE ASSEMBLY (J) of the fixture.
- Restore power to the outlet at the breaker or fuse box.
Replacement Parts
Part Name | Part Number |
---|---|
HARDWARE KIT | HDW-H711806 |
CANOPY | CPY-H711806 |
CHAIN | CHN-H711806 |
GLASS | GLS-H711506 |
For more information and additional products, please visit our website: www.hvlgroup.com.
WARNING/CAUTION
- DISCONNECT POWER BEFORE RE-LAMPING OR WIRING THE FIXTURE.
- READ ALL INSTRUCTIONS COMPLETELY BEFORE STARTING INSTALLATION.
- TO AVOID THE RISK OF FIRE OR SHOCK, FIXTURE MUST BE INSTALLED IN COMPLIANCE WITH ALL APPLICABLE NATIONAL AND LOCAL ELECTRICAL/BUILDING CODES.
- THE INSTALLATION AND MAINTENANCE OF THIS UNIT SHOULD BE COMPLETED BY A LICENSED ELECTRICIAN OR CERTIFIED FACTORY TRAINED TECHNICIAN.
- CALIFORNIA PROP 65: THIS LIGHTING FIXTURE CONTAINS CHEMICALS KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER, BIRTH DEFECTS, AND/OR OTHER REPRODUCTIVE HARM.
- WASH HANDS AFTER USE.
- UNPACK FIXTURE, PARTS AND PARTS BAG(S) BEFORE DISCARDING THE CARTON.
- MAKE CERTAIN THAT ALL PARTS ARE FOUND.
- INSPECT THE FIXTURE PRIOR TO INSTALLATION FOR ANY DAMAGE.
- HVLG DOES NOT PAY OR REIMBURSE ELECTRICIAN FEES.
- FIXTURE MAY NOT BE RETURNED ONCE IT HAS BEEN INSTALLED.
- SEE WARRANTY FOR EXCEPTIONS.
- PLEASE CLEAN WITH A SOFT, DRY CLOTH ONLY! DO NOT USE CLEANSERS.
FIXTURE INSTALLATION
- Attach the MOUNTING PLATE (A) onto the junction box using the MOUNTING SCREWS (B). This fixture is designed to be mounted on standard round or octagon junction box. The junction box must be securely mounted to the structure of the building.
- Open the end link on the CHAIN (I) and attach to the loop on the FIXTURE ASSEMBLY (J). Hang the FIXTURE ASSEMBLY (J) on the CHAIN (I) at your desired height, and remove excess CHAIN (1).
- Feed the wire through the CHAIN (I) , SCREW COLLAR (G), CANOPY (H), SCREW COLLAR LOOP (F), NIPPLE (E), and MOUNTING PLATE (A), and screw the NIPPLE (E) onto the MOUNTING PLATE (A).
- Open the top link on the CHAIN (1), and Hang the FIXTURE ASSEMBLY (J) to the SCREW COLLAR LOOP (F).
- Cut off excess wire, and strip the insulation off the end of the leads.
- Attach the Ground wire (Green) to the ground inside the junction box (Generally green or bar copper wire or the GROUND SCREW (C) on the MOUNTING PLATE (A). NEVER CONNECT GROUND WIRE TO “HOT” WIRE! FAILURE TO FOLLOW THIS COULD RESULT IN SERIOUS INJURY OR DEATH!
- Connect the fixture lead the ridges) to the neutral (Generally white) wire in the outlet box. Fasten the wires together with an approved fastener (WIRE NUT) (D). Starting I” below the fastener, tightly wrap the connection with electrical tape so that the connections seals the end of the fastener. MAKE SURE THERE ARE NO EXPOSED WIRE OF STRANDS THAT COULD CAUSE A DANGEROUS SHORT CIRCUIT!
- Connect the smooth fixture leads with to the hot (Generally black) wire in the junction box. Fasten the joined wires same as previous step. NEVER REVERSE HOT AND NEUTRAL WIRES. FAILURE TO FOLLOW THIS COULD RESULT IN SERIOUS INJURY OR DEATH!
- Push the wires back into the junction box. Lift up the CANOPY (H) up to the ceiling, and secure with the RING (G).
- Screw the BULB (K) into the SOCKET of the fixture. THIS FIXTURE IS RATED FOR 8 WATT TYPE G16.5 LAMP. DO NOT EXCEED THE RECOMMENDED WATTAGE!
- Hang the GLASS (L) on the FIXTURE ASSEMBLY (J) of the fixture.
- Restore power to the outlet at the breaker or fuse box.
PART
PART(S) | REPLACEMENT PART NAME | NUMBER |
---|---|---|
A,B,C,D,E,F,G | HARDWARE KIT | HDW-H711806 |
H | CANOPY | CPY-H711806 |
I | CHAIN | CHN-H711806 |
H | GLASS | GLS-H711506 |
References
Read User Manual Online (PDF format)
Loading......