HEARTH HOME technologies IFT-RC400 IntelliFire Touch Remote Control and Auxiliary Control Module Installation Guide
- June 12, 2024
- HEARTH HOME technologies
Table of Contents
- Introduction
- IFT-RC400 & ACM Installation
- Determine Location
- Wall Mount Installation (Optional)
- Brand/Dealer Programming Procedure
- Pairing the IFT-RC400 to the Electronic Control Module (IFT-ECM)
- LCD Screen Calibration Procedure
- Wiring Diagram
- Operation
- Maintenance
- Frequently Asked Questions/Troubleshooting
- IntelliFire Touch Electronic Control Module (IFT-ECM)
- Troubleshooting
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
www.MyFireplaceBlower.com
1-800-466-4045
IFT-RC400 & IFT-ACM
IntelliFire Touch® Remote Control & Auxiliary Control Module
Installation Instructions
Leave this manual with party responsible for use and operation.
Introduction
The IntelliFire Touch Remote Control (IFT-RC400) is a hand-held wireless
device that is designed to control the functions of Hearth & Home Technologies
products equipped with IntelliFire™Touch technology. It can be used to control
the flame ON/OFF, flame height, cold climate and programmable timer functions
of a appliance.
The IFT-RC400 is also equipped with a temperature sensor which allows it’s use
as a thermostat to set the desired room temperature.
The IntelliFire Touch auxiliary control module (IFT-ACM) is included in this
kit. The ACM is an AC powered device that controls peripheral devices such as
lights, fans and Power Vents approved for use in Hearth & Home Tech- nologies
products that are equipped with IntelliFire Touch technology. It is connected
to and controlled by the Intel- liFire Touch Electronic Control Module (IFT-
ECM).
IFT-RC400 & ACM Installation
A. Precautions
This device is tested and safe when installed in accordance with this
installation manual. Do not install any components that may be damaged.
Do not modify, disassemble, or substitute any of the components included with
this kit. Installation of this unit must be done by a qualified service
technician.
The location of this device may affect performance. An assessment of the
location should be done prior to installation for optimum performance.
Hearth & Home Technologies disclaims any responsibility for, and the warranty will be voided by, the following actions:
-
Installation and use of any damaged system component.
-
Modification of the system component.
-
Installation other than as instructed by Hearth & Home Technologies.
-
Installation and/or use of any component part not approved by Hearth & Home Technologies.
Any such action may cause a fire hazard. -
Read, understand and follow these instructions for safe installation and operation.
Determine Location
Determine the location for the IFT-RC400. The selected location should be in the same space as the gas appliance with visual sight of the fireplace. The device must be placed within 30 feet (9.14 m) of the appliance, but should not be exposed to extreme heat. The IFT-RC400 is approved for interior installation and should not be used in exterior applications.
- Keep remote control out of reach of children.
C. Kit Contents
- IFT-RC400 Remote Control (SRV2326-110)
- Radio Frequency Module (IFT-RFM) (SRV2326-120)
- AAA Batteries (4)
- Wall Mount
- 1 inch #6 Screws (2)
- Drywall Anchors (2)
- IntelliFire Touch Auxiliary Control Module (IFT-ACM) (SRV2326-150)
- Power cable that connects AC receptacle to IFT-ACM (SRV2326-152)
- 1 inch sq. Piece of Velcro
D. Installation Step
CAUTION! Do not install damaged components. If you received components
that are damaged, contact your dealer for assistance.
-
Remove the contents from the packaging.
-
Locate the IntelliFire Touch electronic control module (IFT-ECM) in the control cavity of the appliance and move the three-position switch to the OFF position. See Figure 1.
-
Connect the IFT-RFM to the IFT-ECM by aligning the pins and tabs and pushing the IFT-RFM into the IFTECM until both tabs snap into position. Ensure the two components are fastened securely to one another. See Figure 1.
-
Remove protective rubber cap from connector on the top of the IFT-ECM. See Figure 2.
-
Attach velcro included with the IFT-ACM to the bottom of the ACM. See Figure 3.
-
Connect the IFT-ACM to the IFT-ECM by aligning the pins and tabs and pushing the IFT-ACM onto the IFT- ECM until both tabs latch in place. Ensure the IFTECM and IFT-ACM are aligned with each other and fastened securely. See Figure 3.
WARNING! Risk of Shock! DO NOT touch male pins.
Leave rubber cap on all ports unless port is being connected to an accessory kit.
-
The IFT-ACM can provide power to HHT approved kits including fan, lights and power vent.
• To connect a fan kit to the IFT-ACM, insert the three prong male plug from the fan into the receptacle located on the right side of the IFT-ACM. See Figure 4.
• To connect a light kit to the IFT-ACM, remove protective rubber cap labeled ‘LIGHTS’ and connect to the female cord that was supplied in your lights kit into the three male pins on the IFT-ACM. See Figure 4.
• To connect a power vent kit to the IFT-ACM, remove protective rubber cap labeled ‘AUX’ and connect to the female cord that was supplied in your power vent kit into the three male pins on the IFT-ACM. See Figure 4.
WARNING! Risk of Shock! DO NOT touch male pins.
Leave rubber cap on all ports unless port is being connected to an accessory kit. -
Connect the female end of the power cable that came with the kit into the IFT-ACM. Ensure that power cable is securely and fully inserted into the IFT-ACM. Plug the three prong male plug into the junction box of the appliance. Verify that the junction box has power. See Figure 4.
-
Move the three-position switch on the IFT-ECM to the REMOTE position. The green LED will blink three times. A few seconds later, an audible “beep” will oc- cur to indicate that the system is ready.
-
Set the RC400 face down on flat surface when installing batteries. DO NOT touch the screen during battery installation or removal.
-
Remove the battery cover from the back of the IFTRC400 and install the four AAA batteries in the proper orientation marked in the battery cavity. Ensure the child lock switch adjacent to the battery cavity is in the UNLOCKED position. See Figure 5.
-
Program the IFT-RC400 for the correct brand of appliance using the “Brand Programming” instructions in Section F of this instruction.
-
Follow the pairing procedure, as described in the Section G of this instruction, to pair the IFT-RC400 to the IFT-ECM.
Wall Mount Installation (Optional)
-
Detach the IFT-RC400 from the wall mount.
-
Secure the wall mount on a flat wall surface using the two #6 screws and wall anchors provided. See Figure 6.
-
Place BRAND/ the IFT-RC400 inside the wall mount. See Figure 9.
Brand/Dealer Programming Procedure
This procedure allows the dealer to select the brand input and dealer
information for the consumer’s use.
The contact information will be accessible to the consumer through the “Dealer
Info” screen on the secondary menu.
It is also displayed automatically in the event of an issue with the appliance
or as a maintenance reminder.
To access these selections and program your contact information, please follow
these steps.
- Insert batteries into the IFT-RC400. Wait for a beep to confirm the remote is on.
- Locate the programming hole on the back side of the remote. It is marked as “P” on the right side above the battery cover as shown in Figure 5.
- Using a paper clip or similar item, press and release the programming button. This sequence must be done while the screen is illuminated.
- Select your choice of product brand from the list on the IFT-RC400 screen. See Figure 7.
- Enter the name of the dealer or service company that will service this customer by entering the name on the screen.
- Enter the telephone number that the customer will use to contact the service company or dealer.
- A “splash” screen will appear showing the brand you selected. “MAIN MENU” will appear next, indicating that the programming process is complete.
Note: The screen will time out after 7 seconds if a selection is not made. If this occurs, return to step 2 to access the selections and continue the programming process.
Pairing the IFT-RC400 to the Electronic Control Module (IFT-ECM)
Note: The display will remain illuminated if you hold a finger on the
screen. When you are ready to make your next selection, you must remove your
finger and then continue with your next selection.
CAUTION! Risk of Burns! DO NOT program the IFT Remote Controls to the
IFT-ECM when flame or cold climate function is on or when appliance is hot.
- If adding a new IFT-RC400 to the appliance, follow the steps in Section F.a.
- If IFT-RC400 is currently paired to IFT-ECM, and adding ACM or other optional accessory feature(s), follow the steps in Section F.b.
Note: If additional components are added such as blowers, lights or Power
Vent after initial pairing, the pairing process must be repeated again to
detect additional components.
a. Pairing new IFT-RC400 to Electronic Control Module (IFT-ECM)
-
On the IFT-ECM, move the ON/OFF/REMOTE switch to the REMOTE position. The green LED will blink three times. A few seconds later, an audible “beep” will occur to indicate that the system is ready.
Note: If the green LED continues to blink slowly (system is searching for a clear channel), wait until it stops before proceeding to step 2. -
Locate the pairing hole on the IFT-ECM. See Figure 9. Using a paper clip or similar item, press and release the pairing button. The IFT-ECM will “beep” once and the green LED will blink for 14 seconds. During the 14 seconds, it is normal for accessories such as lights or fan to energize momentarily. While the green LED on the IFT-ECM is blinking, tap anywhere on the gray indicator bar located at the top of the IFT-RC400 screen. Tap on the pairing function as shown in Figure 10. If the IFT-RC400 has been paired successfully to the IFT-ECM, a double audible ‘beep” will be heard from the IFT-ECM..
-
If the pairing is unsuccessful, repeat steps 1 & 2.
Note: If additional components are added such as blowers, lights or Power
Vent after initial pairing, the pairing process must be repeated again to
detect additional components.
NOTICE: Only one IFT-RC400 remote control and one IFT-RC150 wireless wall
switch can be programmed into an IFT-ECM. To program both an IFT-RC400 and an
IFT- RC150 to an IFT-ECM, repeat the same steps separately for the IFT-RC400
and the IFT-RC150.
b. Re-Pairing existing IFT-RC400 after adding ACM, blower kit, light kit or
powervent
Note: Whenever adding an accessory to an IFT system, the ECM must be re-paired
to complete the installation.
- Verify that all the wire connections are complete, and verify that the ACM is powered by 120V.
- On the IFT-ECM, move the ON/OFF/REMOTE switch to the REMOTE position. The green LED will blink three times. A few seconds later, an audible “beep” will occur to indicate that the system is ready.
- Locate the pairing hole on the IFT-ECM. See Figure 9. Using a paper clip or similar item, press and release the pairing button. The IFT-ECM will “beep” once and the green LED blink for 14 seconds. During the 14 seconds, it is normal for accessories such as lights or fan to energize momentarily.
- Touch the screen of the remote. As soon as the main screen appears, tap on the gray indicator bar on the top edge of the screen display. Next, immediately tap the pairing icon as shown in Figure 10. Successful pairing will be indicated by a double beep from the IFT-ECM.
Note: During re-pairing, some versions of the RC400 may display ‘Now pairing remote to product’ before the being able to reach the diagnostic menu on remote. This message will impair the ability to access the pairing ICON button. See Figure 8.
If the “Now pairing remote to product” icon occurs:
- Verify that all the wire connections are complete, and verify that the ACM is powered by 120V.
- On the IFT-ECM, move the ON/OFF/REMOTE switch to the REMOTE position. The green LED will blink three times. A few seconds later, an audible “beep” will occur to indicate that the system is ready.
- Remove the battery cover and install three of the four AAA batteries in the reomote control. Leave one of the batteries out of the remote control. The fourth battery will be installed during step 5.
- Locate the pairing hole on the IFT-ECM. See Figure 8. Using a paper clip or similar item, press and release the pairing button. The IFT-ECM will “beep” once and the green LED blink for 14 seconds. During the 14 seconds, it is normal for accessories such as lights or fan to energize momentarily.
- After pressing and releasing the pairing button, quickly install the battery into the RC400.
- As soon as the main screen appears, tap on the gray indicator bar on the top edge of the screen display. Next, immediately tap the pairing icon as shown in Figure 10. Successful pairing will be indicated by a double beep from the IFT-ECM.
NOTICE: Only one IFT-RC400 remote control and one IFT-RC150 wireless wall switch can be programmed into an IFT-ECM. To program both an IFT-RC400 and an IFT-RC150 to an IFT-ECM, repeat the same steps separately for the IFT-RC400 and the IFT-RC150.
LCD Screen Calibration Procedure
This procedure allows the dealer to calibrate the touch screen, in the event that the screen becomes unresponsive to touch commands. Depending on the firmware installed in the RC400, two methods are available to enter screen calibration mode. Use step 1 and 2 below if the RC400 serial number second alpha character is A to F. Use step 3 and 4 if alpha character is G or later.
-
Remove the battery cover. Remove the batteries.
-
Touch and hold LCD screen while inserting the batteries.
The following screen will display. Continue with steps 4 to 7.
-
With RC400 software versions G and later, screen calibration can only be activated by the following procedure:
(a). Install Batteries. Within 1 second after the last battery is installed, the screen is touched and held.
(If the screen touch starts >1 sec after the batteries are installed, the screen calibration mode will not activate).
(c). Hold screen touch continuously for 6 to 8 seconds.
If the screen touch is < 6 sec, the screen calibration function will not activate; if screen touch is > 8 sec, the screen calibration will not activate. User must release the key between 6-8 sec after first touch.
(d). If done correctly, the Screen calibration function appears (Figure 11). -
Touch screen to continue, the screen below will display. Follow the screen instructions, and touch and release on the filled circles. For best results, use a stylus. You will be prompted to repeat this clockwise around the four corners of the screen.
-
After touching and releasing this last point, the following screen appears.
-
Touch screen anywhere to return IFT-RC400 to normal screen display.
Wiring Diagram
IntelliFire Touch System Wiring Diagram – without Power Vent
Figure 15. IFT-RC400 Wiring Diagram without Power Vent
Wiring Diagram (continued)
IntelliFire Touch System Wiring Diagram – with Power Vent
Figure 16. IFT-RC400 Wiring Diagram with Power Vent
Operation
Introduction
This operation section serves as a quick reference to the screen, functions
and indicators on your IntelliFire Touch remote control.
SCREEN
FUNCTIONS
Turn Flame On/Off
Toggle this function to turn ON or OFF your appliance.
Note: The display will remain illuminated if you hold a finger on the
screen. When you are ready to make your next selection, you must remove your
finger and then continue with your next selection
Thermostat
You can set and maintain your desired room temperature with the thermostat
function. This function automatically adjusts your appliance to maintain the
desired set temperature (ST).
To achieve the most accurate thermostat function, locate your IFT-RC400 remote
control in the same general space that you want to have the temperature
controlled by your appliance. For best results, keep your IFT-RC400 control
away from direct radiant heat from the appliance, adjacent windows and doors,
HVAC vents, and direct sunlight.
To use the thermostat function, access the main menu screen on your remote,
and select thermostat. Next, simply select your desired set temperature by
using the arrow keys and press ON to confirm the setting. The actual room
temperature (RT), measured by your IFT-RC400 remote, will be displayed in the
upper right corner of the main menu screen. To turn the thermostat function
off, simply select thermostat on the main menu screen and select OFF.
If the RT cools to more than 2 °F lower than the ST for at least 2 minutes,
then your appliance will automatically turn ON. The thermostat function will
automatically adjust the flame height based on the difference between the RT
and the ST. As the RT rises closer to the ST, the flame height will
automatically adjust down. If the RT rises 2 °F above the ST for at least 2
minutes, then your appliance will automatically turn OFF.
During thermostat use, you will not be able to set your desired flame height
level. Your appliance will automatically adjust flame height based on the
difference between the RT and ST.
Flame Height
You can set your desired flame height level to affect the ambiance and control
the heat output.
Your appliance will remember the previous flame height setting and adjust the
flame to that level 10 seconds after start.
Timer
For your convenience a timer can be set up to 180 minutes to turn off your
fireplace. The timer will turn the flame off automatically at the selected
preset time.
To use the timer function, press “Timer” on the main screen, select time by
using up and down arrows, then press ON. To turn the timer off , select timer
from main screen and select OFF.
Child Lock
A child lock is available underneath the battery cover. When the lock is
enabled, the screen will lock and no functions can be selected.
Lights
If your appliance is equipped with lighting features, use this function to
adjust them to your desired intensity. The lights can be adjusted whether the
flame is on or off.
Fan Speed
If your appliance is equipped with the fan feature, use this function to
increase or decrease the amount of heat released into your room. A built-in
delay timer will turn the fan on three minutes after your appliance has been
running to prevent cool air from being pushed into the room. If the flame is
turned off with the fan ON, the fan will continue to run for 12 minutes then
shutdown as long as the flame stays off.
Your appliance will remember the previous fan speed setting and automatically
adjust to that level 3 minutes after start-up.
**Power Vent***
Power Vent technology makes it possible to install a gas appliance virtually
anywhere. The Power Vent is a fan powered accessory that pulls exhaust from
the appliance providing longer and more flexible venting configurations. A
Power Vent is a standard accessory on some products and an option on others.
When a Power Vent is detected, a pre-purge of 120 seconds is automatically
required. During this time, the power icon is temporarily replaced with 2MIN,
90s, 60s, and 30s, denoting the countdown until the appliance turns on. All
other functions, except for TURN FLAME OFF are disabled during this time.
The Power Vent is always ON when the flame is ON. When the flame is turned
off, a post-purge time of approximately 20 minutes will occur. Cold-climate
function and battery backup are disabled if a Power Vent is used.
INDICATORS
Temperature Display
You can toggle the temperature display between °F and °C by tapping on the
Room Temperature area.
HOT
This indicates that the appliance is still hot, even when the appliance is
off.
Diagnostics Menu
Tap anywhere in the gray indicator bar area to display all functions below.
When red, it indicates an error has been detected.
Cold Climate
This function turns on a small pilot flame and keeps the air inside your
appliance warm while not in use. It is a useful feature in colder weather to
minimize condensation on the appliance glass.
Note: Temperature Display You can toggle the temperature display between
°F and °C by tapping on the Room Temperature area.
This indicates that the appliance is still hot, even when the appliance is
off. This feature is disabled when a Power Vent is installed on the appliance.
Note: The continuous pilot will automatically turn OFF after 166 hours if
appliance is not actively used. If Flame ON is activated before 166 hours, the
automatic timer will re-start.
Remote Control Battery
Remote control battery life indicator. If the batteries on your remote are
low, a notification will display on the screen asking you to ‘Replace Remote
Batteries’ or ‘Must Replace Remote Control Batteries to Operate Appliance.
Refer to Replace Remote Batteries Section.
Note: To extend the time between changing batteries, Lithium Ion and
rechargable NiMN AAA batteries can be used.
Sorry your appliance did not start.
Try again by pressing Flame On.
Your appliance did not start during the last Flame On command. Verify that you
have power and gas to your appliance. Press the Turn Flame ON icon again,
verify that the appliance accepts command with an audible beep, and turns on
the flame within 90 seconds.
*=Optional Feature
Backup Battery
The battery life indicator is for a backup power source located inside your
appliance. It is intended to operate the appliance in the event of a power
failure.
your owner’s manual for your appliance on how to utilize this feature.
Batteries should only be used as an appliance power source in the event of a
power outage. Batteries should not be used as a primary long-term power
source.
Note: Battery backup is not available if a Power Vent is installed.
Pairing
The green icon indicates that the remote is paired to your appliance and can
operate it. If the icon is gray, it is not paired. Please contact your dealer
and report this issue.
Call Dealer – Pilot Flame Error
Your appliance has been disabled. Please contact your dealer and report this
issue.
Call Dealer – Appliance Safely disabled
Your appliance has been disabled. Please contact your dealer and report this
issue.
Call Dealer – Power Vent and Fan
Your appliance has detected that an accessory is not functional. Please
contact your dealer to report this issue.
Sorry your appliance did not start.
Try again by pressing Flame On.
Your appliance did not start during the last Flame On command. Verify that
you have power and gas to your appliance. Press the Turn Flame ON icon again,
verify that the appliance accepts command with an audible beep, and turns on
the flame within 90 seconds.
Fan will turn on within 3 minutes
Your appliance has a built-in delay that prevents the fan from operating
within the first 3 minutes of operating the appliance. This allows the air to
be heated to a comfortable temperature before the fan circulates it.
Remote Control Communication Error
Your remote control is not able to communicate with your appliance. Verify
that you have power to your appliance. If there is a power outage, verify that
appliance battery backup is fitted with new batteries. After taking these
actions, communication can be re-established by pressing the screen to
activate the remote control. It may take several minutes for remote control to
re-establish pairing.
Replace Remote Batteries OR Must Replace Remote Batteries to Operate
Appliance
Your remote batteries are low. Recommend immediate replacement before using remote to control appliance.
- Set the RC400 face down on flat surface when installing batteries. DO NOT touch the screen during battery installation or removal.
- Remove the battery cover from the back of the IFT-RC400 and install the four new AAA batteries in theproper orientation marked in the battery cavity. Ensure the child lock switch adjacent to the battery cavity is in the UNLOCKED position. See Figure 1.
Maintenance
Your appliance will remind you to schedule routine service after 300 hours of
Flame ON time is accumulated.
Please contact your dealer for a 300 hour inspection to ensure your appliance
is operating at peak performance.
To reset the 300-hour maintenance reminder if the RC400 displays the following
message:
-
Wake-up your remote control display by touching anywhere on the touch screen.
-
Tap the ‘Dismiss’ Icon.
The system will reset the maintenance reminder. Tap ‘Main Menu’ to return to the main menu.
To reset the 300-hour maintenance reminder if the RC400 displays the following message: -
Wake-up your remote control display by touching anywhere on the touch screen.
-
Turn the remote over and insert, press and hold a paperclip type object in the ‘P’ button hole for at least 10 seconds.
-
Double-beep from the remote will indicate that the remote will reset the 300-hour maintenance reminder.
If the remote 300-hour maintenance message does not clear on the first try, repeat above steps.
Frequently Asked Questions/Troubleshooting
Symptom | Possible Cause | Corrective Action |
---|
The appliance does not respond to commands from the IFT-RC400 display does not
light up when screen is touched.| Batteries are depleted.| Install NEW
batteries.
Batteries are incorrectly oriented.| Verify batteries are installed in correct
orientation as shown on batteries receptacle.
The display on IFT-RC400 lights up when screen is touched but it does not respond to commands.
| Touchscreen has lost calibration.| Touchscreen needs to be re-calibrated.
Call dealer to have screen re-calibrated.
Child Lock is ON.| Check child lock icon located at the top of the IFT-
RC400 dis- play. If ON, it will show as a ‘locked’ symbol. To unlock, remove
battery compartment door, locate child lock switch and move to ‘unlock’
position. Verify child lock icon on screen is now dis- played in ‘unlock’
position.
The IFT-RC400 displays the following message on-screen: No dealer info
available| Dealer information not programmed into remote.| Remote will still
provide all available functions, and appliance is fully available for use.
Call dealer to have them program the IFT-RC400.
The IFT-RC400 displays the following message on-screen: Call “Dealer Name &
Number” to schedule maintenance.|
300 hours of use. Appliance is still fully functional.
| The appliance has been burning for 300 hours and is due for a regular maintenance check. Call dealer to have them perform maintenance.
The room temperature displayed on the IFT-RC400 is either slow or quick to respond while operating in thermostat mode.
| IFT-RC400 is placed at a very short distance or too far away from the
appliance.| Try to keep the IFT-RC400 close to the appliance but not directly
in front of it. The remote acts as the thermostat mode room temperature
sensor.
IFT-RC400 is placed in the path of an air draft or vent.| Move the IFT-RC400
away from the direct path of air flow.
The remote acts as the thermostat room temperature sensor..
Flame Modulation| The IFT system is designed to automatically adjust the
flame intensity based on the difference between the desired room temperature,
and actual temperature. In thermostat mode, the hearth appliance will start in
HI flame, but as the actual temperature approaches the desired set temperature
on the remote, the flame intensity will automatically decrease. Auto- matic
flame modulation will result in more control of the tem- perature, but will
cause the appliance to cycle OFF/ON less.
The appliance turns OFF the flame after extended periods of operation| 9
hour safety shutdown timer| This is normal behavior. The appliance has a
safety timer that will automatically turn OFF the flame after nine hours of
con- tinuous operation.
IFT-RC400 displays the following message on-screen: Fan will turn on within 3
minutes.| ****
Functioning as intended.
| The appliance has a three minute delay timer before the fan is turned ON.
This allows the air surrounding the appliance to be heated before being pushed
into the room.
IFT-RC400 displays the following message on-screen:
‘Replace Remote Batteries’ or ‘Must Replace Remote Batteries to Operate
Appliance’.| ****
Low batteries in IFT-RC400.
| ****
Install new batteries in the IFT-RC400.
IFT-RC400 is displaying an incorrect brand.| IFT-RC400 was programmed
incorrectly.| Call dealer to have them program the IFT-RC400 with cor- rect
branding. The IFT-RC400 is still fully functional and the appliance is
unaffected.
After turning flame ON using IFT- RC400, the flame does not turn ON
immediately and instead a two minute timer is displayed.| ****
Power vent is installed on the appliance.
| This is expected behavior and the two minute timer is called a pre-purge timer. The flame will turn ON at the expiration of the timer.
Frequently Asked Questions/Troubleshooting (continued)
Symptom | Possible Cause | Corrective Action |
---|
__
__
IFT -RC400 displays the following message on-screen: Appliance safely
disabled. Call dealer for service.
In addition the LED indicator on the IFT-ECM will flash twice red and once
green indefinitely.
| Ignitor wires (orange) or flame sense wire (white) is shorted to chassis
ground.| Verify that pilot sense and ignitor leads are not shorted to chas-
sis ground and the protective covering has not melted or is cut. Replace pilot
if necessary.
IFT-ECM is unable to sense flame due to contamination on flame sensing rod.|
Measure pilot sense lead resistance. If more than 1 Ohm, clean flame sensor
rod with fine steel wool and measure re- sistance again. If resistance still >
1 ohm, replace pilot.
Ignitor and sense wires are incorrectly wired.| Verify that the sense lead
(white) is securely terminated to the “S” terminal on the IFT-ECM, and that
the ignitor lead (orange) is terminated to the “I” terminal on the IFT-ECM.
Pilot appears to be ‘missing’ sparks from the ignitor.| Verify that pilot
sparks 8 secs ON, 2 secs OFF, and discharges consistently between the hood and
the ignitor electrode. Verify spark gap is 0.095 to 0.135 inches, and adjust
if necessary.
__ The room temperature displayed on the IFT-RC400 is either slow or
quick to respond while operating in thermostat mode.| IFT-RC400 is placed at a
very short distance or too far away from the appliance.| Try to keep the IFT-
RC400 close to the appliance but not di- rectly in front of it.
IFT-RC400 is placed in the path of an air draft or vent.| Move the IFT-RC400
away from the direct path of air flow.
__ Flame Modulation| The IFT system is designed to automatically adjust
the flame intensity based on the difference between the desired room
temperature, and actual temperature. In thermostat mode, the hearth appliance
will start in HI flame, but as the actual temperature approaches the desired
set temperature on the remote, the flame intensity will automatically
decrease. Auto- matic flame modulation will result in more control of the tem-
perature, but will cause the appliance to cycle OFF/ON less.
The appliance turns OFF the flame after extended periods of operation|
__ 9 hour safety shutdown timer| This is normal behavior. The appliance has
a safety timer that will automatically turn OFF the flame after nine hours of
unin- terrupted operation.
__ IFT-RC400 does not pair or unpair from the IFT-ECM| __ IFT-ECM
is not connected to its power source| Verify IFT-ECM is connected to power and
the three position switch is set to REMOTE. If operating off battery backup,
ensure that all four batteries are NEW. Follow pairing process listed in
section F.
__ Noisy radio environment is preventing IFT-ECM and IFT- RC400 from
communicating.| The IFT-ECM and IFT-RC400 operate on the 915MHz radio band.
Allow up to 10 minutes for the IFT-ECM and IFT-RC400 to establish contact. If
the problem does not get resolved try powering OFF and ON both the IFT-ECM and
IFT-RC400 and perform pairing function listed in section 2F.
IFT-RC400 displays the following message on-screen: Fan will turn on within 3
minutes”| __ Functioning as intended.| The appliance has a three minute
delay timer before the fan is turned ON. This allows the air surrounding the
appliance to be heated before being pushed into the room.
IFT-RC400 displays the following message on-screen:
‘Replace Remote Batteries’ or ‘Must Replace Remote Batteries to Operate
Appliance’.| __ Low battery in IFT-RC400.| __ Install new
batteries in the IFT-RC400.
The flame height on the IFT- RC400 does not appear to be doing anything.|
Stepper motor is not connected.| Check if the 4 pin wiring harness from the
stepper motor is connected to the IFT-ECM.
IFT-RC400 is displaying an incorrect brand.| IFT-RC400 was programmed
incorrectly.| Call dealer to have them program the IFT-RC400 with correct
branding. IFT-RC400 is still fully functional and the appliance is unaffected.
After turning flame ON using display, the flame does not turn ON immediately
and instead a two minute timer is displayed.| __ Power vent is installed
on the appliance.| This is expected behavior and the two minute timer is
called a pre-purge timer. The flame will turn ON at the expiration of the
timer.
Symptom| Possible Cause| Corrective Action
---|---|---
__
__
__
IFT-RC400 displays the following message on-screen: “Remote Control Communication Error.”
| No power to Appliance| Verify home circuit breaker is on and master reset is
on (if equipped).
Power Outage| Check power to appliance or if ECM battery backup is being
used, install four (4) new AA batteries in backup.
IFT-ECM Mode| Verify selector switch in “Remote” mode.
IFT-ECM Power| Verify IFT-ECM connected to AC adapter and AC adapter is
plugged into the Junction Box.
IFT-ECM no longer paired to RC400| Follow instructions on pairing IFT-RC400 to
the Electronic Con- trol Module (ECM)
__
__
The IFT-ACM does not respond to commands from the IFT-RC400
| IFT-ACM was newly installed and not paired.| Refer to Section D7 and make
sure that the pairing procedure has been followed especially if the IFT-ACM
was newly installed.
The power cord between IFT-ACM and junction box is disconnected.| Refer to
Section D7 and make sure the power cable is properly inserted into the IFT-ACM
and the junction box.
IFT-ACM and IFT-ECM are not latched.| Refer to Section D5 and check the
connection between the IFT- ACM and IFT-ECM by making sure they are latched
together.
__** IFT-RC400 display the following message on-screen: Call Dealer
Error: Fan| Convection blower malfunction.| Using an RMS voltage
meter, check the voltage coming out of the fan port on the IFT-ACM when the
fan is set to highest level on the IFT-RC400. If the voltage measured is close
to 120V AC then power down the appliance and install a new fan and verify if
the issue has been resolved.
Fuse in IFT-ACM is blown.| Using an RMS voltage meter, check the
voltage coming out of the fan port on the IFT-ACM when the fan is set to
highest level on the IFT-RC400. If voltage measured is closer to zero, then
replace the IFT-ACM itself
IFT-ACM is not responding to IFT- RC400.| Follow steps listed in the previous
symptom.
Fan is not plugged into IFT-ACM.| Check wiring and connections
Spade connectors are miswired.| Some Fans may be connected to the
IFT-ACM using spade con- nectors. For safety, turn off the power to the
appliance and check to see if the wires on either end of the spade connector
do not match in color as they might be miswired.
IFT-RC400 display the following message on-screen: Call Dealer Error:
Lights| Ember/backlighting malfunction.| Using an RMS voltage meter,
check the voltage coming out of the lights port on the IFT-ACM when the lights
are set to highest level on the IFT-RC400. If the voltage measured is close to
120V AC then power down the appliance and install a new light kit and verify
if the issue has been resolved.
Fuse in IFT-ACM is blown.| Using an RMS voltage meter, check the
voltage coming out of the lights port on the IFT-ACM when the lights are set
to highest level on the IFT-RC400. If voltage measured is closer to zero, then
replace the IFT-ACM itself.
IFT-ACM is not responding to IFT- RC400.| Follow steps listed in the second
symptom.
Lights are not plugged into IFT- ACM.| Check wiring and connections.
**
LED controller is not functioning.
| Some appliances come with an LED controller that plugs into the Lights port
on the IFT-ACM. Verify its wiring and that it is function- ing and if not
replace it and verify if the problem is resolved.
Lights are blinking and/or fan and Power Vent blowers are fluctuating.|
__ Poor quality of power from local power station.| Check with customer if
they are also noticing issues with other unrelated appliances and if other
lighting fixtures are also blinking/dimming randomly. If so, install a surge
suppressor be- tween the hearth appliance and its power source.
IFT-RC400 displays the following message on -screen: Sorry your appliance did
not start. Try again by pressing Flame On.| No power to appliance. No gas to
appliance. Accumulation of air in gas line from extended period of appliance
inactivity. Gas control system failure.| Verify that appliance has power and
gas. Verify that the appli- ance accepts flame ON commands with an audible
beep, and successfully turns flame on within 90 seconds. If this failure per-
sists, contact dealer for service.
IntelliFire Touch Electronic Control Module (IFT-ECM)
IFT-ECM Detailed Operating Instruction
-
The Electronic Control Module (IFT-ECM) has a three-position ON/OFF/REMOTE selector switch that must be set for proper operation. See Figure 12. When changing switch positions,it is important to pause in each position for 1-2 seconds.
OFF Position:
The appliance will not respond to any commands from a wired wall switch, IFT- RC150 or IFT-RC400 remote controls. The unit should be in the OFF position during installation, service, backup battery installation, fuel conversion and to reset the IFT- ECM in the event the system goes into a LOCK- OUT mode as the result of a system error. When switched to the OFF position while the appliance is operating, the system will shut down.
ON Position:
The appliance will ignite and run continuously at the HI flame setting. No adjustment in flame height is possible.
The IFT-ECM has a safety feature that will automatically shut down the fireplace after 9 hours of continuous operation in the ON position.
Remote Position:
The remote position allows operation of the appliance from a wired wall switch, IFT-RC400 or IFT-RC150 remote controls. The IFT-ECM switch must be in this position to pair the IFT-ECM with the IFT-ACM (if installed), and/or IFT- RC400 and IFT- RC150 remote controls. See the IFT-RC400 or IFT- RC150 installation manual for detailed instructions on pairing the IFT-ECM with the remote controls. After successfully pairing a IFT-RC400, all installed accessories can be controlled by the IFT-RC400
(see IFT-RC400 user manual). The RC150 allows the user to turn ON/OFF the flame in the appliance and activate the Cold Climate mode if desired. The IFT- ECM has a safety feature that will automatically shut down the fireplace after 9 hours of continuous operation without receiving a command from the IFT-RC400 or IFT-RC150. -
If multiple control options are installed, the IFT-ECM will respond to the last command from the wired wall switch, IFT-RC400 or IFT-RC150. The wired wall switch is NOT available if a Power Vent is used.
-
The Pilot button on the IFT-ECM activates the Cold Climate function of the fireplace. This function lights the pilot flame ONLY to provide enough heat in the firebox to reduce condensation in cool, high humidity ambient conditions. To activate the Cold Climate press and hold the Pilot button for one second and release. The IFT-ECM will flash two green LED blinks, beep twice and light and rectify the pilot flame when pressed to activate. To turn off Cold Climate, press and hold the Pilot button for one second and release. The IFT-ECM will flash one green LED blink, beep once and shut down the pilot flame. If remote controls are paired with the IFT-ECM, this feature can also be activated with the IFT-RC400 and/or IFT-RC150.
-
An IFT-ECM reset is required if the module is in a lock-out condition. When this occurs, the appliance is shut down and the IFT-ECM status indicator LED will be blinking a RED/GREEN error code along with a one-time audible double- beep. If the IFT-ECM is in a lock-out condition, refer to the troubleshooting chart to interpret the error code and take corrective action as required. To reset the IFT-ECM after a lock-out error:
CAUTION! Risk of burns! Appliance surfaces are hot when operating and
during cool down. Use care and wear gloves when opening the front and
accessing components inside the appliance.
Note: Some appliances may be equipped with a remote mounted reset switch.
- Be aware the appliance may be HOT, use care in accessing the IFT-ECM.
- Set the IFT-ECM 3-position selector switch to OFF position.
- Wait five (5) minutes to allow possible accumulated gas to clear.
- Set the IFT-ECM 3-position selector switch to ON or IFT-REM position. Module will beep once and flash a three GREEN LED code on successful startup.
- If placed in ON position, the appliance will ignite normally if the error condition was corrected.
- If placed in IFT-REM position, use the paired IFT- RC400, IFT-RC150 or wired wall switch to start the appliance; appliance will ignite normally if the error condition was corrected.
- If the IFT-ECM re-enters the lock-out condition after these steps, call your dealer for service.
DANGER
Risk of Explosion
DO NOT cycle the ON/OFF/REM selector switch more than one time within a
five minute period. Gas may accumulate in firebox. Call a qualified service
technician.
Troubleshooting
With proper installation, operation and maintenance your gas appliance will
provide years of trouble-free service. If you do experience a problem, this
troubleshooting guide will assist a qualified service technician in the
diagnosis of a problem and the corrective action to be taken. This
troubleshooting guide can only be used by a qualified service technician.
IntelliFire Touch Ignition System
Error Codes:
ECM LED Error Codes | Description |
---|---|
3 Red: 1 Green | IFT-RC400 error message: ‘Appliance Safely Disabled’, pilot |
sparks for 90 sec, no flame rectification.
2 Red: 1 Green| IFT-RC400 display: ‘Error Pilot Flame’, pilot valve solenoid
not detected.
2 Red: 2 Green| Sparking feedback signal error, spark coil failure.
5 Red: 1 Green| IFT-RC400 display: ‘Error Power Vent’ (if installed).
See Troubleshooting matrix for more detail on Lock-out Error Codes, Possible
Causes and Corrective Actions.
Troubleshooting:
Symptom | Possible Cause | Corrective Action |
---|
__ Pilot won’t light, module clicks but no spark 90 sec, 3 Red/1 Green
Lock out.| Incorrect wiring.| Verify ‘S’ (White) sense wire and ‘I’ (orange)
ignitor wire are connected to correct terminals on IFT-ECM.
__ Loose connections or electrical shorts in wiring.| Verify no loose
connections or electrical shorts in wiring from module to pilot assembly.
Verify wire insulation is not dam- aged. Verify wires are not grounding out to
chassis, pilot burn- er, or any other metal object. Replace any damaged wires.
Ignitor gap is too large.| Verify spark gap is approximately 0.095” (2.41 mm)
to 0.135” (3.43 mm).
__ Pilot won’t light, there is no noise or spark.| No AC power, AC/DC
adaptor faulty, backup batteries (if being used) depleted, IFT- ECM slider
switch in OFF position.| Verify IFT-ECM slider switch is in ON or IFT-REM
position. Verify AC power available to junction box. Verify AC/DC adap- tor is
plugged into junction box and ECM. Verify AC/DC adaptor output voltage is
between 5.7-6.3 Vdc. If battery pack is used, check battery pack voltage is
4.2 V (if not, replace batteries).
Shorted or loose connection in system wiring or wiring harness.| Verify system wiring configuration. Remove and reinstall wir- ing harness that plugs into module. Check continuity of wires in valve wiring harness. Replace any damaged components.
Poor or no system ground.| Verify black ground wire in valve harness is connected to metal chassis of fireplace.
__ Pilot won’t light, there is no noise or spark, 2 Red/1 Green Lockout.| __ Pilot solenoid not detected.| Check if valve harness orange wire is connected to pilot so- lenoid valve. Check pilot solenoid resistance, nominal is 40 ohms. If open or shorted, replace valve. Check valve harness wire continuity, if open replace 6-pin harness.
Pilot won’t light, there is no noise or spark, 2 Red/2 Green Lockout.| Spark coil failure.| Replace ECM.
Troubleshooting (continued)
Symptom | Possible Cause | Corrective Action |
---|
__ Pilot sparks but does not light, after 90 sec, 3 Red/1 Green
Lockout.| __ No gas supply.| Verify incoming gas line ball valve is
‘Open’. Verify inlet pres- sure is within requirement for gas type used.
Contact gas sup- plier.
ECM has poor ground.| Verify wiring, check valve harness black wire is
securely grounded to metal chassis.
__ Gas valve defective.| Check pilot valve solenoid kick and hold
voltages during igni- tion cycle. Kick V should be >1 V, hold V minimum 0.26
V. If voltages are OK, replace gas valve.
__** Pilot lights but main burner does not light. Pilot continues to
spark for 90 sec then goes into 3 Red/1 Green Lockout.| **
No flame detected. Flame rectification issue.
| Check if white sense lead is securely connected to ‘S’ terminal of IFT-ECM. Check resistance of sense lead between sense rod tip and connector to IFT-ECM, should be less than 1 ohm
– if not, replace pilot assembly. Check system ground, ensure black valve harness wire is securely attached to metal chassis. Check wiring for damage. With system OFF, check resistance between tip of sense rod and pilot hood, should be resistance (>1 M-ohm).
__ No flame detected or sense rod contamination.| With glass assembly
installed, verify pilot flame is engulfing flame sense rod on pilot assembly.
Verify inlet gas pressure is correct for gas type. Polish flame sense rod with
fine steel wool to remove any contaminants that may have accumulated.
__ Pilot lights and rectifies, but main burner does not light.| __
Main valve solenoid.| Check if green wire in valve harness is connected to
green main valve solenoid. Check main valve solenoid resistance, nominal is 60
ohms. If open or shorted, replace valve. Verify valve inlet pressure is
correct for gas type.
__ Pilot and main do not light, ECM goes into 5 Red/1 Green Lockout.|
__ Power Vent (PV) Failure.| Power Vent blower defective – check wiring
to IFT-ACM, check if blower is working. Check if PV pressure switch is
connected to brown and black wire in 6-pin valve wire harness. Check if
pressure switch is closed (shorted) when PV blower is running. Refer to PV
troubleshooting instructions.
__ Appliance lights and runs for a few minutes then shuts down and/or
appliance cycle ON and OFF with less than 90 sec of ON time.| __ Shorted
or loose connection in flame detection circuit.| Check if white sense lead is
securely connected to ‘S’ terminal of IFT-ECM. Check resistance of sense lead
between sense rod tip and connector to IFT-ECM, should be less than 1 ohm
– if not, replace pilot assembly. Check system ground, ensure black valve
harness wire is securely attached to metal chassis. Check wiring for damage.
With system OFF, check resistance between tip of sense rod and pilot hood,
should be resistance (>1 M-ohm).
__ Poor flame rectification or contaminated sense rod.| With glass
assembly installed, verify pilot flame is engulfing flame sense rod on pilot
assembly. Verify inlet gas pressure is correct for gas type. Polish flame
sense rod with fine steel wool to remove any contaminants that may have
accumulated. Verify no soot deposits are in sense rod to pilot hood gap.
Logs are set up wrong.| Remove and re-install logs per the log placement
instructions.
__**__** Damaged pilot assembly.| Verify the pilot assembly ceramic
insulator around the flame sensing rod is not cracked, damaged or loose. Check
re- sistance between tip of sense rod and IFT-ECM connector, should be less
than 1 ohm. Replace pilot assembly if damage is detected.
FCC Compliance Statement:
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference
that may cause undesired operation of the device.
FCC Warning
Note: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses,
and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Caution: The Federal Communications Commission warns that changes or
modifications not expressly approved by the party responsible for compliance
could void the user’s authority to operate the equipment.
Canadian DOC Notice
This digital apparatus does not exceed the (Class A/Class B) limits for radio
noise emissions from digital apparatus set out in the Radio Interference
Regulations of the Canadian Department of Communications.
Canadian IC Notice
This device complies with RSS-210 of Industry and Science Canada. Operation is
subject to the following two conditions:
(1) this device may not cause interference, and
(2) this device must accept any interference, including interference that may
cause undesired operation of the device.
Please contact your Hearth & Home Technologies
dealer with any questions or concerns.
For the location of your nearest
Hearth & Home Technologies dealer,
please visit www.hearthnhome.com.
Hearth & Home Technologies
7571 215th Street West, Lakeville, MN 55044
www.hearthnhome.com
Hearth & Home Technologies • IFT-RC400 & IFT-ACM Installation Instructions •
2326-982 Rev. Q
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>