GERMAN GPU-6SSM Rapid Fast Flow Electric Water Heater User Manual
- June 12, 2024
- German
Table of Contents
- GERMAN GPU-6SSM Rapid Fast Flow Electric Water Heater
- Product Information
- Product Usage Instructions
- Safety Instructions
- Features
- Installation Instructions
- Operating Instructions
- Product Structure
- Installation Diagram
- Wiring Diagram
- Specifications
- Warranty Terms & Conditions
- Customer Service & Repair Centre
- ABOUT COMPANY
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
GERMAN GPU-6SSM Rapid Fast Flow Electric Water Heater
Product Information
- Product Name: Rapid Fast Flow Electric Water Heater GPU-6SSM
- Warranty: Online Warranty Registration is required. For Warranty Terms & Conditions, please refer to the last page of the user manual.
Product Usage Instructions
Safety Instructions
Warning:
- Do not allow children to touch or play with the water heater. Supervision is required during use to prevent scalding, electrical shock, or injuries.
- This appliance is not intended for use by persons (including children) with reduced physical, sensory, or mental capabilities unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety.
- An electric-leakage protection device must be installed to the power inlet. The electric current of this protection device should be below 30mA.
Note: German Pool will NOT provide warranty service on any product installed with unauthorized components or devices.
PTV Device:
- The PTV device must be tested and operated regularly (suggested once every 3 months) to remove calcium carbonate deposits and ensure it is not blocked.
- The PTV drain pipe must be installed continuously downwards at an angle, and the surroundings must not be frosted. The drain pipe must be left open to the atmosphere to prevent endangering personal safety or causing property damage.
Features
The GPU-6SSM (Central Type) water heater is designed for multi-point
applications. It conforms to the Standards of International Electro-technical
Commission (IEC) and complies with international safety standards and
waterworks regulations. The GPU-6SSM is equipped with a 5-Tier Safety Device
for absolute safety:
- Stainless Steel Inner Tank
- Thermal Insulation
- Heating Element
- Water Supply Source (Rated Pressure / Max. Inlet Water Pressure)
- Pressure & Temperature Relief Valve / Combined Thermostat / Cutout
- Water Resistance Conformity Certifications: IPX4, Electrical Product (Safety) Regulation, Hong Kong, IEC 60335-2-21:2012, IEC 60335-1:2013
Note: Under normal working conditions, incoming pressure should not exceed 0.6 MPa. If the incoming water pressure exceeds 0.6 MPa, a separate pressure control device is necessary. German Pool will not provide any repair service until a pressure control device is installed.
Please read these instructions and warranty information carefully before use
and keep them handy for future reference.
Please register your warranty information now !For Warranty Terms &
Conditions,
please refer to the last page of this user manual.
Safety Instructions
- Warning
1. Do not allow children to touch or play with the water heater. Supervision is required during use, in order to prevent the danger of a scald, electrical shock or any other injuries.
2. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
3. If the temperature is set above 50˚C, cold water must be mixed in to prevent the danger of a scald.
4. An electric-leakage protection device must be installed to the power inlet. The electric current of this protection device should be below 30mA.
-
Warning
Please install water heater in accordance to the instructions stated on this booklet. German Pool will NOT provide warranty service on any product installed with unauthorized components or devices. -
Warning
1. The water heater must be installed together with a Pressure and Temperature Relief Valve (PTV), so that when the water temperature inside the tank rises to 90°C or when water pressure reaches 1000kPa, hot water will be released through the drain pipe of the PTV.
2. The PTV device must be tested and operated regularly (suggested once every 3 months) to remove calcium carbonate deposits and to ensure that it is not blocked.
3. The PTV drain pipe must be installed continuously downwards at an angle and the surroundings must not be frosted. The drain pipe must be left open to the atmosphere, and to ensure the hot water drips from the PTV will not endanger personal safety or cause property damage.
Features
GPU-6SSM (Central Type) is designed for multi-point application. Conform to the Standards of International Electro-technical Commission (IEC ) and comply with international safety standards and waterworks regulations. GPU-6SSM is built-in with “5-Tier Safety Device” for absolute safety:
- Automatic Thermostatic Control
- Thermal Cutout
- Temperature Relief Valve
- Pressure Relief Valve
- Anti-Back Syphon Device
Stainless Steel Inner Tank
| Constructed of Japanese heavy gauge stainless steel, specially made for high
temperature and pressure applications. It is durable and free of rust, corrosion, deformity and hassle.
---|---
Thermal Insulation| Maximum thermal insulation is achieved by high-density
melamine foam
between the inner tank and outside casing.
Heating Element| Prime quality stainless steel heating element ensures maximum thermal
efficiency even in places where different power rating / wattage applices.
Water Supply Source| Main supply or water tank supply.
Rated Pressure| 1.0 MPa
Max. Inlet Water Pressure| 0.6 MPa
Pressure & Temperature
Relief Valve
| When water temperature reaches 90°C, or water pressure reaches 1MPa,
water will be released through the Temperature Relief Valve.
Combined Thermostat / Cutout
| Combined Thermostat/Cut-Out provides automatic temperature control at
preset temperature to accommodate individual bathing habits and save energy; built-in thermal cut-out ensures safety.
Water Resistance| IPX4
Conformity| Electrical Product (Safety) Regulation, Hong Kong.
Certifications| IEC 60335-2-21:2012
IEC 60335-1:2013
- Under normal working conditions, incoming pressure should not exceed 0.6 MPa. Otherwise, a separate pressure control device is necessary. When incoming water pressure exceeds 0.6 MPa, German Pool will not provide any repair service until a pressure control device is installed.
Installation Instructions
Pre-Installation Notice
Installation should be done by a licensed technician using the supplied parts.
German Pool is not responsible for any defect or damage caused by incorrect or
unauthorized installation.
Positioning
Position water heater near water tap / point of use in order to minimize heat
loss. For wall-mount style, appropriate anchor screws must be used and wall
should be strong enough to withstand the weight of water heater. Keep a
minimal distance between wall and water heater. you can also use the mounting
bracket for positioning.
Electric Wiring
- Use an independent wire (refer to table below) leading from the meter box and connect it to an independent on/off switch outside bathroom. Extend the wire through the grey wire grip on the water heater. Dismount the bottom plate and wire up Neutral (N), Life (L) and Earth ( ) terminals.
- This water heater must be earthed at all time.
Heating Element Rating (kW)| Electric Current (A)| Wiring (mm²)
---|---|---
3kW| 15 A (1PE)| 2.5 mm²
2kW| 10 A (1PE)| 2.5 mm²
Power Switch
- The external switch is used to completely disconnect water heater from power supply.
- It should disconnect all poles, and a contact separation of at least 3 mm must be present. IEE wiring regulations should be observed when the water heater is installed in the bathroom.
Testing
When the piping and wiring are connected and inner tank has been filled with
water, switch on the power. The indicator on the water heater will be lit.
Turn control knob to the desired temperature (Max. temperature is 75°C). Do
not use the control knob as an on/off switch.
Positioning
Position water heater near water tap / point of use in order to minimize heat
loss. For wall-mount style, appropriate anchor screws must be used and wall
should be strong enough to withstand the weight of water heater. Keep a
minimal distance between wall and water heater.
Connecting PTV and Inlet/Outlet Pipes
- A Pressure & Temperature Relief Valve (PTV) is supplied with each GPU water heater. Water will be released through the PTV when water temperature reaches 90˚C or when water pressure reaches 1000 kPa in the inner tank. (It is normal that small amount of water may drip out.)
- PTV and water inlet & outlet must be installed according to the following instructions:
- Fit PTV to the marked position (normally it is located on the upper side of the water heater and is labeled “PTV”).
- When connecting the pipe,the PTV must point downward.The outlet of the discharge pipe connecting the PTV must be positioned approximately 25-50mm away from the ground, so that it is easily observable when hot water is being drained to ensure safety.
- Connect the inlet pipe (blue) with water supply. Then connect the outlet pipes (red) with supply pipe leading to points of use. The diameter of piping should be 1/2” BSP.
- Turn on the hot water tap. Turn on water supply switch until the inner tank has been filled up with water. The inner tank has been filled up when water flows from the water tap.
ATTENTION
Appliance intended to be permanently connected to the water mains and not connected by a hose-set.
WARNING!
After initial installation and water and electricity testings, if the storage
water heater will not be put to use immediately, after testing is completed,
make sure to follow these instructions:
- Disconnect water and power source to the water heater;
- Completely drain the residual water in the water heater;
- When the water heater is finally put to normal use, user MUST first completely fill up the water heater with water BEFORE reconnecting the power source and commencing heating.
NOTE:
If water source is from underground water or near river area where seawater
intrusion is possible, user MUST COMPLY with all of the above steps to ensure
proper function of water heater.
INSTALLATION REQUIREMENT
ATTENTION: When installing the water heater, must leave ample space for
future maintenance and repair.
The minimum requirements are:
- at least 100 mm space from the ceiling
- at least 200 mm on either side of the wall
- at least 300 mm underneath the heater
Operating Instructions
Note
When incoming water pressure exceeds 0.6 MPa, German Pool will not provide any
repair service until a pressure control device is installed.
Draining
To drain out water from the inner tank, first switch off both power and water
supply. Let hot water inside the inner tank cool down. Then unscrew the drain
pipe nut to release water.
Source of Water Supply
If the water source is a river, a well, underground water or has relatively
high mineral content, user must clean the heating element regularly to ensure
it will operate at optimum thermal efficiency.
Water Shortage
During water shortage, do not drain water from in-ner tank. The heating
element would be damaged if it is not submerged under water. When water supply
resumes, turn on hot water tap and let water flows through the shower head
before switching on the power.
Pressure & Temperature Relief Valve (PTV)
- The discharge pipe connecting to the PTV must be pointing downward and be left open to the atmosphere in a frost-free environment.
- Turn the lift handle or rotational cup of the PTV regularly in order to prevent deposits in water causing blockage to the easing gear.
- When water is discharged through PTV pipe, shut off power and water supply immediately. Then contact our Customer Service Centre for repair. (It is normal that small amount of water may drip out.)
Under normal working conditions, incoming pressure should not exceed 0.6 MPa. Otherwise, a separate pressure control device is necessary. (It is normal that small amount of water may drip from PTV after installation of pressure limiting valve.)
Product Structure
- Anti Back Siphonage Device
- Pressure & Temperature Relief Valve (PTV)
- Heating Element (Inside)
- Outlet (Hot)
- Inlet (Cold)
- Combined Thermostat/Cutout
Installation Diagram
Caution: After confirmation of installation location, properly secure the mounting bracket with screws on the wall, align the holes of the back plate of the water heater with the mounting bracket, and downwardly hang the water heater.
Wiring Diagram
( 1-Phase 220 V~)
(1-Phase 220 V~)
Specifications
Model | GPU-6SSM | GPU-6SSM Y |
---|---|---|
Voltage (1Phase) | 220V | |
Frequency | 50Hz | |
Power (1Phase) | 3kW | 2kW |
Dimensions | (H)740 mm (W)355 mm (D)175 mm | |
Net Weight | 16.2kg | |
Filled Weight | 35.7kg |
- Specifications are subject to change without prior notice.
- If there is any inconsistency or ambiguity between the English version and the Chinese version, the Chinese version shall prevail.
- Refer to www.germanpool.com for the most up-to-date version of the Operating Instructions.
Warranty Terms & Conditions
Under normal operations, the product will gurantee a 1-year full warranty provided by German Pool (effective from the date of purchase).
- This warranty is not valid until customer registration information is received by our Service Centre within 10 days of purchase via one of the following means:
- Visit our VIP App and register online: (Scan the QR Code on the right)
- Visit our website and register online: www.germanpool.com/warranty
- Complete the attached Warranty Card and mail it back to our Customer Service Centre.
Please fill out the form below. This information and the original purchase invoice will be required for any repairs. Warranty will be invalidated if information provided is found to be inaccurate.
- Customer who fails to present original purchase invoice will not be eligible for free warranty service.
- Customer should always follow the operating instructions. This warranty does not apply to:
- labour costs for on-site installation, check-up, repair, replacement of parts and other transportation costs;
- damages caused by accidents of any kind (including material transfer and others);
- operating failures resulting from applying incorrect voltage, improper usage, and unauthorized installations or repairs.
- This warranty is invalid if:
- the purchase invoice is modified by an unauthorized party;
- the product is used for any commercial or industrial purposes;
- the product is repaired or modified by unauthorized personnel, or unauthorized parts are installed;
- the serial number is modified, damaged or removed from the product.
- German Pool will, at its discretion, repair or replace any defective part.
- This warranty will be void if there is any transfer of ownership from the original purchaser.
Customer Service & Repair Centre
- China Hong Kong
- Unit B, G/F, Sunshine Kowloon Bay Cargo Centre, 59 Tai Yip Street, Kowloon, Hong Kong
- Tel : +852 2333 6249
- Fax : +852 2356 9798
- Email : repairs@germanpool.com
- China Macau
- A, 1 Andar, Mei Kui Kuong Cheong Fase 2, No.515 Avenida Do Conselheiro Borja Macau
- Tel : +853 2875 2699
- Fax : +853 2875 2661
ABOUT COMPANY
German Pool (Hong Kong) Limited
- Hong Kong
- Room 113. Newport Centre Phase II. 116 Ma Tau Kok Road. Tokwawan. Kowloon. Hong Kong.
- Tel: +852 2773 2888
- Fax: +852 2765 8215
- China
- 8th, Xinxiang Road, Wusha Industrial Park, Daliang, Shunde, Foshan, Guangdong
- Tel:+86 757 2219 6888
- Fax:+86 757 2219 6809
- Macau
- 1 Andar A, Edf. Mei Kui Kuong Cheong Fase 2, 515 Av. do Conselheiro Borja
- Tel: +853 2875 2699
- Fax: +853 2875 2661
- www.germanpool.com