Kepler FX6 Facial Recognition Device Instruction Manual

June 5, 2024
Kepler

Kepler FX6 Facial Recognition Device Instruction Manual
Kepler FX6 Facial Recognition Device

Product Introduction

Overview

Figure 1 FX6
Product Introduction
**Figure 2 Temperature measuring module of FX6

Figure 3 FX6 prototype with the card reader on the column support
Product Introduction
**

Facial recognition, a biometric recognition technology based on the facial features of human, is a typical application of artificial intelligence. Facial recognition has been applied to some industries, such as the public security field (border inspections and criminal investigations), the transportation field (airports, train stations, and bus stops), and the education industry (facial attendance, dormitory access control, and kindergarten pick-up). It has great prospect as a portal for connecting people and intelligence.

The infrared non-contact temperature measuring technology is widely used in the field of medical temperature measurement. It can accurately measure the body temperature without direct contact between people, greatly reducing the probability of cross infection of viruses and bacteria.

The Kepler FX6 facial recognition device is equipped with a new built-in infrared non-contact temperature measuring module based on facial recognition. During facial recognition, the device can simultaneously measure the temperature of the person’s forehead and facial skin in a non-contact, accurate, reliable, efficient, and unaware manner. For those whose body temperature exceeds a certain threshold, the device will generate an abnormal warning and display their temperature. The unique waterproof and dustproof design of the device meets the IP65 protection requirements, effectively guaranteeing the service life of the device in most environments. Therefore, the device can be widely used in complex indoor and outdoor scenarios.

The Kepler FX6 facial recognition device addresses the high labor costs and low measurement efficiency of traditional body temperature detection devices, and reduces the contact between people and terminals and between people during detection, enabling the rapid screening of crowds.

Features

Effective bioassay with a dual-lens camera

The dual-lens camera can effectively distinguish between living body and pictures, avoiding deception.

Simultaneous detection of body temperature, focusing on personal health

The built-in infrared body temperature detection module achieves a recognition accuracy of ±0.4°C. During facial recognition, it also measures the body temperature of personnel and immediately generates an alarm when the body temperature is abnormal.

Ultrafast and large-capacity deep learning algorithm, accommodating various scenarios

Tens of millions of facial images can be analyzed based on the latest MxNet deep learning framework and aggregate algorithm, achieving world-leading facial recognition. A local facial database containing up to 5000 facial images is provided, achieving high recognition accuracy (> 99.8%).

Service continuity in offline recognition mode

The offline mode of the device ensures continuity of the facial recognition and access control services upon a sudden network disconnection, without being restricted by the network.

Presumable data transfer and offline retransmission, ensuring secure data transmission

Multiple mechanisms such as presumable data transfer and offline retransmission are enabled for device logs, ensuring the integrity and security of data upon network failure.

Application Scenarios

The device provides superb front-end intelligent processing capabilities and is widely applicable to residential estates, communities and streets, governmental organizations, transportation junctions, airports and stations, and schools. In addition to facial recognition, it also measures the body temperature of personnel. The device collaborates with back-end and cloud business platforms to provide customers with solutions such as personnel access permission management, personnel health status detection, visitor management, and attendance management.

 Product Specifications

Functions

Table 2- 1 Functions

Category Item Description
Facial recognition algorithm Recognition rate ≥ 99.8%
Bioassay Bioassay can prevent attacks from non-living body such as

photos/videos on mobile phones, photos/videos on computers, and printed black and white/color photos.
Recognition distance| 0.5 m
Recognition angle| 0°–90°
Recognition speed| ≤ 1s
Personnel management| Facial database| Local facial database with 20,000 images
Personnel management| Add, delete, modify, and query
Multiple recognition patterns| Facial recognition, person-certificate comparison, and body temperature detection
Body temperature detection| Measuring angle/FOV| ±5°
Measuring accuracy| ±0.4°C
Fever alarm| The device generates an alarm when detecting a fever.
Network| Wi-Fi| Wi-Fi access is supported.
Wired network port| RJ45 wired network access is supported.
Functions| Facial recognition| The captured facial images can be compared with the local built-in database in real time, and the comparison results are logged.
Access control| Access control is enabled based on the facial recognition results, to manage the personnel in the controlled area.
Time-based control| Time-based control is enabled for the personnel, allowing them to pass only in the specified period of time.
Regional control| Regional control is enabled for personnel, to prohibit personnel in specific regions from passing.

Hardware Specifications

Table 2- 2 Basic hardware specifications

Hardware specifications of Kepler FX6

Module| Parameter| Specifications
Main unit| Dimensions| 243.0 mm (L) × 138.0 mm (W) × 30.0 mm (H)
OS| Android 5.1
Protection class| IP65
Processor| CPU| RK3288, 4-core A17 high-performance facial recognition chip
Clock speed| 1.8 GHz
Storage| Memory| 2 GB
Storage device| 8 GB
Display| Screen| 8.0 inches
Resolution| 800×1280
Display ratio| 10:16 in portrait mode
Camera| HD built-in cameras| 2M HD camera + 2M infrared night-vision HD camera
Lens| 6 mm
Temperature measuring module| Infrared temperature measuring module|
High-precision infrared temperature measuring module
Communication| LAN| Built-in Wi-Fi
Bluetooth| Yes
Audio effect| Loudspeaker| 8 ohms/ 2 W
Fill light| LED| Built-in fill LED
Power supply| Power adapter| 12 V/2 A
Operating environment| Operating temperature| –20°C to +60°C
Operating humidity| < 85%
Power consumption| System power consumption| 15 W

Device Connectors

Kepler FX6 Facial Recognition Device Instruction
Manual

Function ID Description
12 V DC input Standard 12 V/2 A
RJ45 Used for 10/100 Mbps Ethernet transmission
WG output WG_O D0/D1 Used to output recognition results and connect other WG

input devices
WG input| WG_I D0/D1| Used to receive Wiegand signals, such as the IC card number
| | Relay output: used to output gate opening
Relay output/alarm input| O1+/O1–| signals. Alarm input: used to receive signals to enable
| | linkage.
USB connector| USB| Type-A USB connector

Connector Description

Power Connector

of the tail wire at the rear of the device is the power input connector. The details are as follows:

Table 2- 3 Power connector

Signal Direction Function
12 V Inward positive 12 V±20% DC input
GND Outward negative Power ground

Reverse polarity protection and surge protection are provided for the device’s internal power input.

Relay Output

The alarm output is a passive relay Boolean output. The contact voltage capacity is 220 V DC, 250 V AC. The contact current capacity is 1 A. The power capacity is 30 W.

WG Output

This connector is used to output recognition results and connect other WG input devices such as access control boards.

Ethernet Connector

The RJ45/LAN connector of the tail wire at the rear of the device is the camera’s Ethernet connector, used to transmit camera control commands and captured images.

USB

The USB connector is used to connect a USB device such as an ID card reader.

 Module and Code

Code Name Description
-S ID card reader -S indicates that an ID card reader is configured.
None None If no code is carried, no ID card reader is configured.

Installation Mode and Code

Code Installation Mode Picture Remarks
B Wall-mounting by using the backplane

| The device is mounted to the wall by using the backplane.
Z| Column support|


| The column support is used to fasten the device to a gate machine.
L| Long column support|


| The long column support is about 1.4-m high and is directly placed on the ground.

FAQs

  1. How to measure the temperature accurately? The ambient temperature should not change drastically, the head should be within the portrait frame, and the face should not move violently.
  2. Why is the temperature measurement inaccurate after the device is brought indoors from outdoors? After being brought indoors, the device needs to wait for the thermal balance calibration (which takes 20 minutes after power-on as expected) before it can output the normal body temperature.
  3. How to measure the temperature efficiently? The device needs to be aligned with the best area of the face.
  4. Can the device be installed against the light? The device can be installed against the light, but it is not recommended. Be sure to avoid direct sunlight on the temperature sensor.

Release History

Version Date Description
V1.0 July 23, 2019 Released the first official version.
V1.1 September 5, 2019 Modified the device pictures.
V1.2 February 3, 2020 Modified the device appearance based on hardware

iterations and modified the document style.
V1.3| February 7, 2020| Updated    the    device    appearance    pictures and hardware dimensions.
V1.4| February 10, 2020| Optimized the typesetting and added the model classification and FAQs.

Appendix

Table 3- 1 Common models

Model Product Code Package and Accessory Packing
FX6-B FX6-B Device, 12 V power supply, packing cotton, user manual, and
installation backplane 1 piece/box
FX6-Z FX6-Z Device, 12 V power supply, packing cotton, user manual, and
common column support 1 piece/box
FX6-L FX6-L Device, 12 V power supply, packing cotton, user manual, and
1.4-m column support 1 piece/box
**** FX6-S-B **** FX6-S-B Device (with the ID card reader), 12 V power
supply, packing cotton, user manual, and installation backplane **** 1

piece/box
FX6-S-Z| FX6-S-Z| Device (with the ID card reader), 12 V power supply, packing cotton, user manual, and common column support| 1 piece/box
FX6-S-L| FX6-S-L| Device (with the ID card reader), 12 V power supply, packing cotton, user manual, and 1.4-m column support| 1 piece/box

  1. This device may not cause harmful interference.
  2. This device must accept any interference received, including interference that may cause undesired operation.

Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television

which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of more of the following measures:

  1. Reorient or relocate the receiving antenna.
  2. Increase the separation between the equipment and the receiver.
  3. Connect the equipment into an outlet on a circuit different from that to which
    the receiver is connected. Consult the dealer or an experienced radio/TV technician for help.

The device has been evaluated to meet general RF exposure requirement. This
device should be installed and operated with a minimum distance of 20cm between the device and your body.

Company Information

Shenzhen Mustint Technologies Co., Ltd.

Telephone: 4000588192
Email: zhengyifu@mustint.com
Address: Room 1201, Building B3, Kexing Science Park, Nanshan District, Shenzhen

Scan the QR code to add our WeChat customer service:
QR code

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals