RURIS AS140MMA Welding Machine Instruction Manual
- June 12, 2024
- RURIS
Table of Contents
RURIS AS140MMA Welding Machine
INTRODUCTION
Dear customer!
Thank you for the decision to buy a RURIS product and for the trust placed in
our company! RURIS has been on the market since 1993 and during all this time
it has become a strong brand, which has built its reputation by keeping
promises, but also by continuous investments meant to help customers with
reliable, efficient and quality solutions. We are confident that you will
appreciate our product and enjoy its performance for a long time. RURIS does
not only offer its customers equipment, but complete solutions. An important
element in the relationship with the customer is the advice both before the
sale and after the sale, the RURIS customers having at their disposal a whole
network of partner stores and service points.
To enjoy the product you bought, please read the user manual carefully. By following the instructions, you will be guaranteed a long-term use. RURIS company works continuously for the development of its products and therefore reserves the right to change, among other things, their shape, appearance and performance, without having the obligation to communicate this in advance.
SAFETY INSTRUCTIONS
GENERAL PRECAUTIONS
To use the equipment safely, please follow the safety instructions in this
manual. Do not touch parts that present a risk of electric shock or parts that
become hot during operation.
Protective equipment – Wear suitable protective equipment to protect your eyes and head from the radiation emitted by the welding machine.
- Welding helmet (mask), face shield and goggles must be ready at all times in the work area.
- Use a suitable welding helmet to protect your eyes, face, neck and ears from sparks and rays.
- Use non-flammable partition screens to protect other workers from lightning and sparks.
- Wear goggles when cleaning weld splashes.
Fire – Heat from welded parts and electric arc can cause injury.
- Keep flammable materials, including wood, cloths, fuel, gas, etc., away from the work area.
- The walls and floor of the work area should be clean to avoid fire.
- Fire extinguishers must be placed near the work area.
- Do not overload the equipment.
Electric shock – Avoid welding in humid environments or in the rain. Do not allow water to enter the welding machine.
- Make sure the workpiece and cables are connected.
- Replace the cable in time if it is damaged.
- Keep the work area and the machine dry.
- Wear gloves before turning on the power
- Power must be turned off before removing gloves.
Electromagnetic field
- The electromagnetic field can disrupt the normal activity of the heart system.
- The user must reduce the working time, exposing himself as little as possible to the electromagnetic field.
Avoid inhaling fog and gas resulting from the welding process.
Stop welding immediately if you experience irritation of the nose, mouth or
eyes. Facilitate ventilation of the work area.
Equipment Maintenance – Wrong or improper maintenance of the equipment can cause injury to the user. Thus:
- Only authorized persons may perform maintenance and maintenance operations.
- The power supply must be switched off when maintenance is required.
- Make sure that the ground wire, cable, connector, main cord, and power supply are in normal operation condition.
Do not dispose of electrical, electronic industrial equipment and components in household waste! WEEE information. Considering the provisions of GEO 195/2005 – regarding environmental protection and G.E.O. 5/2015. Consumers will take into account the following indications for the delivery of electrical waste, specified below:
- Consumers have an obligation not to dispose of electrical and electronic equipment waste (WEEE) as unsorted municipal waste and to collect this WEEE separately.
- The collection of this so-called waste (WEEE) will be carried out through the Public Collection Service in each county and through collection centers organized by economic operators authorized to collect WEEE. Information provided by the Administration of the Environmental Fund www.afm.ro or the European Union journal.
- Consumers can hand over WEEE free of charge at the collection points specified above
PERSONAL SAFETY
- a) Do not use the appliance while you are tired or under the influence of drugs, alcohol or medication. A moment of negligence during the operation can lead to serious injuries.
- b) Use protective equipment. Always wear eye protection. Safety equipment, such as mask, safety shoes or safety helmet, used under proper conditions, will reduce the risk of injury.
- c) Avoid accidental starting. Make sure the switch is in the off position before connecting.
MACHINE OVERVIEW
The MMA series welding machine adopts advanced inverter technology. It is light, compact and excellent to use. It has high efficiency and performance, easy arc ignition, excellent weld bead formation, small volume and simple operation.
- ON/OFF switch
- Electric current intensity adjustment knob
- Negative terminal (-)
- Positive terminal (+)
- Digital display
TECHNICAL DATA
Model | Ruris AS140MMA | Ruris AS160MMA | Ruris AS180MMA |
---|---|---|---|
Device type | MMA inverter | MMA inverter | MMA inverter |
Supply voltage | 230 V | 230 V | 230 V |
Frequency | 50/60 Hz | 50/60 Hz | 50/60 Hz |
Maximum power
absorbed
| 4.5 kVA| 5.3 kVA| 6.2 kVA
Idle voltage| 60 V| 60 V| 60 V
Welding current
adjustment
| 20-140A| 20-160A| 20-180A
Operating mode| 60%| 60%| 60%
Electrode diameter| 1.6 mm – 3.2 mm| 2.5 mm – 4 mm| 2.5 mm – 4 mm
Insulation class| H| H| H
Protection class| IP21S| IP21S| IP21S
Features
| Digital display, Arc Force, Hot Start, Anti-
stick
| Digital display, Arc Force, Hot Start,
Anti-stick
| Digital display, Arc Force, Hot Start, Anti-
stick
Accessories
| 1.4m ground cable with clamp, 1.6m cable with electrode holder clamp, brush/hammer, 1.8m power cable, brush/hammer, welding mask| 1.4m ground cable with clamp, 1.6m cable with electrode holder clamp, brush/hammer, 1.8m power cable, brush/hammer,
welding mask
| ****
1.4m ground cable with clamp, 1.6m cable with electrode holder clamp, brush/hammer, 1.8m power cable, brush/hammer, welding mask
Net weight| 4.9 kg| 5.1 kg| 5.1 kg
Model| Ruris AS200MMA| Ruris AS250MMA
---|---|---
Device type| MMA inverter| MMA inverter
Supply voltage| 230 V| 230 V
Frequency| 50/60 Hz| 50/60 Hz
Maximum power
absorbed
| 7.1 kVA| 9.5 kVA
Idle voltage| 60 V| 60 V
Welding current
adjustment
| 20-200A| 20-250A
Operating mode| 60%| 60%
Electrode diameter| 2.5 mm – 4 mm| 2.5 mm – 4 mm
Insulation class| H| H
Protection class| IP21S| IP21S
Features
| Digital display, Arc Force, Hot Start, Anti-
stick
| Digital display, Arc Force, Hot Start, Anti-
stick
Accessories
| 1.4m ground cable with clamp, 1.6m cable with electrode holder clamp, brush/hammer, 1.8m power cable, brush/hammer,
welding mask
| 1.4m ground cable with clamp, 1.6m cable with electrode holder clamp, brush/hammer, 1.8m power cable, brush/hammer,
welding mask
Net weight| 5.6 kg| 6.2 kg
WELDING PROCESS
Step 1 : Connect the power cord to a power source.
Step 2 : Connect the ground clip to the negative (-) terminal and the
workpiece.
Step 3 : Mount the electrode in the electrode holder clamp, then connect
the clamp to the positive (+) terminal.
Step 4 : Set the “ON / OFF” switch to the “ON” position and make sure
that the LED indicating the power source lights up.
Step 5 : Make sure that the intensity of the welding current is adequate
for the thickness of the workpiece and the electrode.
Step 5 : After completing the welding process, remove the electrode from
the ground source, put the mask down and set the “ON / OFF” switch to the
“OFF” position.
If you overload the machine (high current welding for a long time), it will stop working and you will have to wait until the machine temperature drops.
Approximate data on welding current and electrode diameter
Electrode diameter | 1.6 mm | 2.5 mm | 3.2 mm | 4.0 mm |
---|---|---|---|---|
Welding current | 30-80A | 60-100A | 80-140A | 140-170A |
Electrodes should be stored in a dry place and protected from moisture in
suitable containers.
The welding parameters obtained depend on the intensity of the current, the
welding position, the diameter and the quality of the electrodes.
GRAPHIC SYMBOLS
- U0 …… .V This symbol shows the secondary voltage without load (in volts).
- X This symbol shows the rated operating cycle.
- I2 …… A This symbol shows the welding current in AMPERS.
- U2 …… V This symbol shows the welding voltage in VOLTS.
- U1 This symbol shows the rated supply voltage.
- I1max … A This symbol shows the maximum absorbed current of the welding unit in
- AMP. I1eff … A This symbol shows the maximum absorbed current of the welding unit in AMP. IP21S This symbol shows the protection class of the welding unit.
S: This symbol indicates that the welding unit is suitable for use in environments where there is a high risk of electric shock.
- This symbol shows that you read the operating instructions carefully before operation.
- This symbol indicates that the welding unit is of single-phase direct current.
- This symbol shows the power supply phase and line frequency in Hz.
- This symbol shows that the welding unit is a MMA.
MAINTENANCE AND TROUBLESHOOTING
The degree of use and working environment must be taken into account when maintaining the device. Proper use and regular maintenance will help you avoid unnecessary damage to the device.
Note: Disconnect the device from the mains before operating the power cords.
DAILY MAINTENANCE
- Check the tightness and insulation of the electrode holder connections and of the ground cable.
- Check the power cord and welding cables. If they are damaged, they must be replaced.
TROUBLESHOOTING
Problem | Cause |
---|---|
The main switch indicator does not light | The device is not powered from the |
mains 1 Check the mains panel fuses
2 Check the device’s power cord and outlet
Poor welding result| The welding result is influenced by several factors. 1 Check that the grounding clamp is attached correctly, that the point of contact is clean, that the cable and its connectors are in good condition.
2. Check if the supply voltage is uneven, too low or too high.
3. Make sure the intensity of the current is set accordingly.
Overheating indicator lit| The device is overheated.
1 Make sure that the cooling air has an unobstructed flow.
2 The operating cycle of the device has been exceeded. Wait for the indicator to go out.
3 Check if the supply voltage too low or too high.
DECLARATIONS OF CONFORMITY
EC DECLARATION OF CONFORMITY
-
Producer: SC RURIS IMPEX SRL
Calea Severinului, nr. 10, Bl. 317b, Craiova, Dolj, Romania -
Tel. 0351 464 632, www.ruris.ro, info@ruris.ro
-
Authorized representative : Eng. Stroe Marius Catalin – General Manager
-
Authorized person for the technical file: Eng. Florea Nicolae – Production Design Manager
-
Machine description: The welding machine ensures the joining of metal parts, in conditions of temperature and pressure, to achieve an atomic bond.
-
Product: Welding machine
-
Product serial number : xx AS140MMA 0001 to xx AS140MMA 9999 (where xx is the last two digits of the year of manufacture)
-
Type: Inverter MMA Model: Ruris AS140MMA
-
Maximum power absorbed: 4.5 kVA
-
Electrode diameter: 1.6 mm – 3.2 mm
We, SC RURIS IMPEX SRL Craiova, manufacturer, in accordance with GD 1029/2008 – regarding the conditions for placing machines on the market, Directive 2006/42/EC – Safety and security requirements, Standard EN ISO 12100:2010 – Machines. Safety, Directive 2014/35 / EU, GD 409/2016 – on low voltage equipment, Directive 2014/30 / EU on electromagnetic compatibility (GD 487/2016 on electromagnetic compatibility, updated 2019) have certified the conformity of the product with the specified standards and we declare that it complies with the main safety and security requirements, does not endanger life, health, occupational safety and has no negative impact on the environment.
The undersigned Stroe Catalin, the manufacturer’s representative, declares on his own responsibility that the product complies with the following European standards and directives:
- SR EN ISO 12100: 2011 / EN ISO 12100: 2010 – Safety of machinery. Basic concepts, general design principles. Basic terminology, methodology. Technical principles;
- SR EN 50445: 2008 / EN ISO 50445: 2008 – Product family standard for demonstrating conformity of equipment for electric pressure welding, electric arc welding and related processes, with basic restrictions on exposure of persons to electromagnetic fields (0 Hz
- 300 Ghz);
- SR EN 60974-10:2015/ EN 60974-10:2014+A1:2015 – Electric arc welding equipment. Part 10: Electromagnetic compatibility (EMC) requirements;
- SR EN 60974-1:2019/A1:2019/ EN 60974-1:2018+A1:2019 – Electric arc welding equipment. Part 1: Current sources for electric arc welding;
- SR EN 61000-3-11:2002/ EN 61000-3-11:2000- Electromagnetic compatibility (EMC). Part 3-11: Limits. Limiting voltage variations, voltage fluctuations and flicker in public low voltage power grids. Equipment with an absorbed current = <75A and which are subject to connection restrictions;
- – SR EN 61000-3-12:2012/ EN 61000-3-12:2011- Electromagnetic compatibility (EMC). Part 3-12: Limits. Limits for harmonic currents produced by equipment connected to low voltage public networks, with an absorbed current> 16 A and ≤75 A per phase;
- SR EN 61000-4-2:2009/ IEC 61000-4-2:2008- Electromagnetic compatibility (EMC). Part 4-2: Test and measurement techniques. Test of immunity to electrostatic discharges
- SR EN IEC 61000-4-3:2014/ IEC 61000-4-3:2020 – Electromagnetic compatibility (EMC). Part 4-3: Test and measurement techniques. Immunity tests on radiated radio frequency electromagnetic fields;
- SR EN 61000-4-4:2013 / EN 61000-4-4:2012- Electromagnetic compatibility (EMC). Part 4-4: Test and measurement techniques. Immunity tests on high voltage pulse trains; SR EN 61000-4-5:2015 / EN 61000-4-5:2014- Electromagnetic compatibility (EMC). Part
- 4-5: Test and measurement techniques. Shockwave immunity tests;
- SR EN 61000-4-6:2014 / EN 61000-4-6:2013- Electromagnetic compatibility (EMC). Part
- 4- 6: Test and measurement techniques. Tests of immunity to conducted disturbances, induced by radio frequency fields;
- SR EN IEC 61000-4-11+AC:2020 / EN IEC 61000-4-11:2020 – Electromagnetic compatibility (EMC). Part 4-11: Test and measurement techniques – Tests for immunity to temporary voltage drops, short-term interruptions and voltage variations for equipment with an input current of 16 A or less per phase;
- Directive 2006/42/EC – on machinery – placing machines on the market;
- Directive 2014/30/EU – on electromagnetic compatibility (GD 487/2016 on electromagnetic compatibility, updated 2019);
- Directive 2014/35/EU, GD 409/2016 – on low voltage equipment.
Other Standards or specifications used:
- SR EN ISO 9001 – Quality Management System
- SR EN ISO 14001 – Environmental Management System
- SR ISO 45001:2018 – Occupational Health and Safety Management System. Make and name of manufacturer: T.F.M.T CO LTD
Note: the technical documentation is owned by the manufacturer. Specification: This statement is in accordance with the original. Terms of validity: 10 years from the date of approval
- Place and date of issue: Craiova, 14.09.2021
- Year of affixing of the CE marking: 2021
- Registration no. : 1151 /9/14/2021
Authorized person and signature:
Eng. Stroe Marius Catalin General Manager of SC RURIS IMPEX SRL
EC DECLARATION OF CONFORMITY
Producer: SC RURIS IMPEX SRL
Calea Severinului, nr. 10, Bl. 317b, Craiova, Dolj, Romania
Tel. 0351 464 632, www.ruris.ro,
info@ruris.ro
- Authorized representative: Eng. Stroe Marius Catalin – General Manager
- Authorized person for the technical file: Eng. Florea Nicolae – Production Design Manager
- Machine description: The welding machine ensures the joining of metal parts, in conditions of temperature and pressure, to achieve an atomic bond.
- Product: Welding machine
- Product serial number: xx AS160MMA 0001 to xx AS160MMA 9999 (where xx is the last two digits of the year of manufacture)
- Type: Inverter MMA Model: Ruris AS160MMA
- Maximum power absorbed: 5.3 kVA
- Electrode diameter: 2.5 mm – 4 mm
We, SC RURIS IMPEX SRL Craiova, manufacturer, in accordance with GD 1029/2008 – regarding the conditions for placing machines on the market, Directive 2006/42/EC – Safety and security requirements, Standard EN ISO 12100:2010 – Machines. Safety, Directive 2014/35 / EU, GD 409/2016 – on low voltage equipment, Directive 2014/30 / EU on electromagnetic compatibility (GD 487/2016 on electromagnetic compatibility, updated 2019) have certified the conformity of the product with the specified standards and we declare that it complies with the main safety and security requirements, does not endanger life, health, occupational safety and has no negative impact on the environment.
We, SC RURIS IMPEX SRL Craiova, manufacturer, in accordance with GD 1029/2008 – regarding the conditions for placing machines on the market, Directive 2006/42/EC – Safety and security requirements, Standard EN ISO 12100:2010 – Machines. Safety, Directive 2014/35 / EU, GD 409/2016 – on low voltage equipment, Directive 2014/30 / EU on electromagnetic compatibility (GD 487/2016 on electromagnetic compatibility, updated 2019) have certified the conformity of the product with the specified standards and we declare that it complies with the main safety and security requirements, does not endanger life, health, occupational safety and has no negative impact on the environment.
The undersigned Stroe Catalin, the manufacturer’s representative, declares on his own responsibility that the product complies with the following European standards and directives:
- SR EN ISO 12100: 2011 / EN ISO 12100: 2010 – Safety of machinery. Basic concepts, general design principles. Basic terminology, methodology. Technical principles;
- SR EN 50445: 2008 / EN ISO 50445: 2008 – Product family standard for demonstrating conformity of equipment for electric pressure welding, electric arc welding and related processes, with basic restrictions on exposure of persons to electromagnetic fields (0 Hz
- 300 Ghz);
- SR EN 60974-10:2015/ EN 60974-10:2014+A1:2015 – Electric arc welding equipment. Part 10: Electromagnetic compatibility (EMC) requirements;
- SR EN 60974-1:2019/A1:2019/ EN 60974-1:2018+A1:2019 – Electric arc welding equipment. Part 1: Current sources for electric arc welding;
- SR EN 61000-3-11:2002/ EN 61000-3-11:2000- Electromagnetic compatibility (EMC). Part 3-11: Limits. Limiting voltage variations, voltage fluctuations and flicker in public low voltage power grids. Equipment with an absorbed current
- <75A and which are subject to connection restrictions;
- SR EN 61000-3-12:2012/ EN 61000-3-12:2011- Electromagnetic compatibility (EMC). Part 3-12: Limits. Limits for harmonic currents produced by equipment connected to low voltage public networks, with an absorbed current> 16 A and ≤75 A per phase;
- SR EN 61000-4-2:2009/ IEC 61000-4-2:2008- Electromagnetic compatibility (EMC). Part 4-2: Test and measurement techniques. Test of immunity to electrostatic discharges
- SR EN IEC 61000-4-3:2014/ IEC 61000-4-3:2020 – Electromagnetic compatibility (EMC). Part 4-3: Test and measurement techniques. Immunity tests on radiated radio frequency electromagnetic fields;
- SR EN 61000-4-4:2013 / EN 61000-4-4:2012- Electromagnetic compatibility (EMC). Part 4-4: Test and measurement techniques. Immunity tests on high voltage pulse trains; SR EN 61000-4-5:2015 / EN 61000-4-5:2014-
- Electromagnetic compatibility (EMC). Part 4-5: Test and measurement techniques. Shockwave immunity tests;
- SR EN 61000-4-6:2014 / EN 61000-4-6:2013- Electromagnetic compatibility (EMC). Part 4-6: Test and measurement techniques. Tests of immunity to conducted disturbances, induced by radio frequency fields;
- SR EN IEC 61000-4-11+AC:2020 / EN IEC 61000-4-11:2020 – Electromagnetic compatibility (EMC). Part 4-11: Test and measurement techniques – Tests for immunity to temporary voltage drops, short-term interruptions and voltage variations for equipment with an input current of 16 A or less per phase;
- Directive 2006/42/EC – on machinery – placing machines on the market;
- Directive 2014/30/EU – on electromagnetic compatibility (GD 487/2016 on electromagnetic compatibility, updated 2019);
- Directive 2014/35/EU, GD 409/2016 – on low voltage equipment.
Other Standards or specifications used:
- SR EN ISO 9001 – Quality Management System
- SR EN ISO 14001 – Environmental Management System
- SR ISO 45001:2018 – Occupational Health and Safety Management System. Make and name of manufacturer: T.F.M.T CO LTD
Note: the technical documentation is owned by the manufacturer. Specification: This statement is in accordance with the original.
- Terms of validity : 10 years from the date of approval
- Place and date of issue: Craiova, 14.09.2021
- Year of affixing of the CE marking: 2021
- Registration no.: 1153 /9/14/2021
Authorized person and signature:
Eng. Stroe Marius Catalin General Manager of SC RURIS IMPEX SRL
EC DECLARATION OF CONFORMITY
Producer: SC RURIS IMPEX SRL
Calea Severinului, nr. 10, Bl. 317b, Craiova, Dolj, Romania
- Tel. 0351 464 632,
- www.ruris.ro,
- info@ruris.ro
- Authorized representative: Eng. Stroe Marius Catalin – General Manager
- Authorized person for the technical file: Eng. Florea Nicolae – Production Design Manager
- Machine description: The welding machine ensures the joining of metal parts, in conditions of temperature and pressure, to achieve an atomic bond.
- Product: Welding machine
- Product serial number: xx AS200MMA 0001 to xx AS200MMA 9999 (where xx is the last two digits of the year of manufacture)
- Type: Inverter MMA
- Model: Ruris AS200MMA
- Maximum power absorbed: 7.1 kVA
- Electrode diameter: 2.5 mm – 4 mm
We, SC RURIS IMPEX SRL Craiova, manufacturer, in accordance with GD 1029/2008 – regarding the conditions for placing machines on the market, Directive 2006/42/EC – Safety and security requirements, Standard EN ISO 12100:2010 – Machines. Safety, Directive 2014/35 / EU, GD 409/2016 – on low voltage equipment, Directive 2014/30 / EU on electromagnetic compatibility (GD 487/2016 on electromagnetic compatibility, updated 2019) have certified the conformity of the product with the specified standards and we declare that it complies with the main safety and security requirements, does not endanger life, health, occupational safety and has no negative impact on the environment.
The undersigned Stroe Catalin, the manufacturer’s representative, declares on his own responsibility that the product complies with the following European standards and directives:
- SR EN ISO 12100: 2011 / EN ISO 12100: 2010 – Safety of machinery. Basic concepts, general design principles. Basic terminology, methodology. Technical principles;
- SR EN 50445: 2008 / EN ISO 50445: 2008 – Product family standard for demonstrating conformity of equipment for electric pressure welding, electric arc welding and related processes, with basic restrictions on exposure of persons to electromagnetic fields (0 Hz300 Ghz);
- SR EN 60974-10:2015/ EN 60974-10:2014+A1:2015 – Electric arc welding equipment. Part 10: Electromagnetic compatibility (EMC) requirements;
- SR EN 60974-1:2019/A1:2019/ EN 60974-1:2018+A1:2019 – Electric arc welding equipment. Part 1: Current sources for electric arc welding;
- SR EN 61000-3-11:2002/ EN 61000-3-11:2000- Electromagnetic compatibility (EMC). Part 3-11: Limits. Limiting voltage variations, voltage fluctuations and flicker in public low voltage power grids. Equipment with an absorbed current
- <75A and which are subject to connection restrictions;
- SR EN 61000-3-12:2012/ EN 61000-3-12:2011- Electromagnetic compatibility (EMC). Part 3-12: Limits. Limits for harmonic currents produced by equipment connected to low voltage public networks, with an absorbed current> 16 A and ≤75 A per phase;
- SR EN 61000-4-2:2009/ IEC 61000-4-2:2008- Electromagnetic compatibility (EMC). Part 4-2: Test and measurement techniques. Test of immunity to electrostatic discharges
- SR EN IEC 61000-4-3:2014/ IEC 61000-4-3:2020 – Electromagnetic compatibility (EMC). Part 4-3: Test and measurement techniques. Immunity tests on radiated radio frequency electromagnetic fields;
- SR EN 61000-4-4:2013 / EN 61000-4-4:2012- Electromagnetic compatibility (EMC). Part 4-4: Test and measurement techniques. Immunity tests on high voltage pulse trains; SR EN 61000-4-5:2015 / EN 61000-4-5:2014-
- Electromagnetic compatibility (EMC). Part 4-5: Test and measurement techniques. Shockwave immunity tests;
- SR EN 61000-4-6:2014 / EN 61000-4-6:2013- Electromagnetic compatibility (EMC). Part 4-6: Test and measurement techniques. Tests of immunity to conducted disturbances, induced by radio frequency fields;
- SR EN IEC 61000-4-11+AC:2020 / EN IEC 61000-4-11:2020 – Electromagnetic compatibility (EMC). Part 4-11: Test and measurement techniques – Tests for immunity to temporary voltage drops, short-term interruptions and voltage
- variations for equipment with an input current of 16 A or less per phase;
- Directive 2006/42/EC – on machinery – placing machines on the market;
- Directive 2014/30/EU – on electromagnetic compatibility (GD 487/2016 on electromagnetic compatibility, updated 2019);
- Directive 2014/35/EU, GD 409/2016 – on low voltage equipment.
Other Standards or specifications used:
- SR EN ISO 9001 – Quality Management System
- SR EN ISO 14001 – Environmental Management System
- SR ISO 45001:2018 – Occupational Health and Safety Management System. Make and name of manufacturer: T.F.M.T CO LTD
Note: the technical documentation is owned by the manufacturer. Specification: This statement is in accordance with the original. Terms of validity: 10 years from the date of approval
- Place and date of issue: Craiova, 14.09.2021
- Year of affixing of the CE marking: 2021
- Registration no. : 1154 /9/14/2021
Authorized person and signature:
Eng. Stroe Marius Catalin General Manager of SC RURIS IMPEX SRL
EC DECLARATION OF CONFORMITY
- Producer: S C RURIS IMPEX SRL
- Calea Severinului, nr. 10, Bl. 317b, Craiova, Dolj, Romania
- Tel. 0351 464 632,
- www.ruris.ro,
- info@ruris.ro
- Authorized representative : Eng. Stroe Marius Catalin – General Manager
- Authorized person for the technical file: Eng. Florea Nicolae – Production Design Manager
- Machine description: The welding machine ensures the joining of metal parts, in conditions of temperature and pressure, to achieve an atomic bond.
- Product: Welding machine
- P roduct serial number : xx AS200MMA 0001 to xx AS200MMA 9999 (where xx is the last two digits of the year of manufacture)
- Type: Inverter MMA
- Maximum power absorbed: 9.5 kVA
- Model: Ruris AS200MMA
- Electrode diameter: 2.5 mm – 4 mm
We, SC RURIS IMPEX SRL Craiova, manufacturer, in accordance with GD 1029/2008 – regarding the conditions for placing machines on the market, Directive 2006/42/EC – Safety and security requirements, Standard EN ISO 12100:2010 – Machines. Safety, Directive 2014/35 / EU, GD 409/2016 – on low voltage equipment, Directive 2014/30 / EU on electromagnetic compatibility (GD 487/2016 on electromagnetic compatibility, updated 2019) have certified the conformity of the product with the specified standards and we declare that it complies with the main safety and security requirements, does not endanger life, health, occupational safety and has no negative impact on the environment.
The undersigned Stroe Catalin, the manufacturer’s representative, declares on his own responsibility that the product complies with the following European standards and directives:
- SR EN ISO 12100: 2011 / EN ISO 12100: 2010 – Safety of machinery. Basic concepts, general design principles. Basic terminology, methodology. Technical principles;
- SR EN 50445: 2008 / EN ISO 50445: 2008 – Product family standard for demonstrating conformity of equipment for electric pressure welding, electric arc welding and related processes, with basic restrictions on exposure of persons to electromagnetic fields (0 Hz
- 300 Ghz);
- SR EN 60974-10:2015/ EN 60974-10:2014+A1:2015 – Electric arc welding equipment. Part 10: Electromagnetic compatibility (EMC) requirements;
- SR EN 60974-1:2019/A1:2019/ EN 60974-1:2018+A1:2019 – Electric arc welding equipment. Part 1: Current sources for electric arc welding;
- SR EN 61000-3-11:2002/ EN 61000-3-11:2000- Electromagnetic compatibility (EMC). Part 3-11: Limits. Limiting voltage variations, voltage fluctuations and flicker in public low voltage power grids. Equipment with an absorbed current
- <75A and which are subject to connection restrictions;
- SR EN 61000-3-12:2012/ EN 61000-3-12:2011- Electromagnetic compatibility (EMC). Part 3-12: Limits. Limits for harmonic currents produced by equipment connected to low voltage public networks, with an absorbed current> 16 A and ≤75 A per phase;
- SR EN 61000-4-2:2009/ IEC 61000-4-2:2008- Electromagnetic compatibility (EMC). Part 4-2: Test and measurement techniques. Test of immunity to electrostatic discharges
- SR EN IEC 61000-4-3:2014/ IEC 61000-4-3:2020 – Electromagnetic compatibility (EMC). Part 4-3: Test and measurement techniques. Immunity tests on radiated radio frequency electromagnetic fields;
- SR EN 61000-4-4:2013 / EN 61000-4-4:2012- Electromagnetic compatibility (EMC). Part 4-4: Test and measurement techniques. Immunity tests on high voltage pulse trains; SR EN 61000-4-5:2015 / EN 61000-4-5:2014-
- Electromagnetic compatibility (EMC). Part 4-5: Test and measurement techniques. Shockwave immunity tests;
- SR EN 61000-4-6:2014 / EN 61000-4-6:2013- Electromagnetic compatibility (EMC). Part 4- 6: Test and measurement techniques. Tests of immunity to conducted disturbances, induced by radio frequency fields;
- SR EN IEC 61000-4-11+AC:2020 / EN IEC 61000-4-11:2020 – Electromagnetic compatibility (EMC). Part 4-11: Test and measurement techniques – Tests for immunity to temporary voltage drops, short-term interruptions and voltage variations for equipment with an input current of 16 A or less per phase;
- Directive 2006/42/EC – on machinery – placing machines on the market;
- Directive 2014/30/EU – on electromagnetic compatibility (GD 487/2016 on electromagnetic compatibility, updated 2019);
- Directive 2014/35/EU, GD 409/2016 – on low voltage equipment.
Other Standards or specifications used:
- SR EN ISO 9001 – Quality Management System
- SR EN ISO 14001 – Environmental Management System
- SR ISO 45001:2018 – Occupational Health and Safety Management System. Make and name of manufacturer: T.F.M.T CO LTD
Note: the technical documentation is owned by the manufacturer. Specification: This statement is in accordance with the original. Terms of validity: 10 years from the date of approval
- Place and date of issue: Craiova, 14.09.2021
- Year of affixing of the CE marking: 2021
- Registration no.: 1155 /9/14/2021
Authorized person and signature:
Eng. Stroe Marius Catalin General Manager of SC RURIS IMPEX SRL
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>