LifeSafty Power AMAG 16DR ProWire Unified Power Wall Mount Owner’s Manual
- June 9, 2024
- LifeSafty Power
Table of Contents
LifeSafty Power AMAG 16DR ProWire Unified Power Wall Mount
Product Information
The AMAG 16DR is a ProWire Unified Power wall mount model that provides access
power systems for AMAG M2150 or M4000 series controllers. It is a dual voltage
system that can be programmed for failsafe / fail secure operation at either
12 or 24 VDC. The system consists of two C8 or M8 control modules that provide
sixteen access control inputs capable of voltage or dry contact activation,
and sixteen outputs that are programmable for failsafe / fail secure
operation. It also includes two D8 modules that provide sixteen auxiliary
outputs.
The system is designed for uniform operation, maintenance, and servicing
across an enterprise. It comes with a pre-installed wire harness for panel
power, lock control, faults, and tamper switch. The wiring is point-to-point,
labeled, color-coded, twisted pair, and shielded communication. The cable
management options include tie wrap or wire duct. The system is managed and
can monitor power, batteries, and sixteen outputs. It is UL294 and ULC S319
joint LSP / AMAG integrated listing compliant.
The system comes in two enclosure styles – E6A1 and E8A – wall mount E8A. The
model nomenclature includes power rating, accessory boards & enclosure, wiring
option, and system type. The wiring options are T16-A, T16-C, P16-A, and
P16-C. The system type includes distributed outputs auxiliary and control. The
enclosure/cable management dimensions are H x W x D (inches).
Usage Instructions
The AMAG 16DR is a power supply system that provides access control inputs and outputs for AMAG M2150 or M4000 series controllers. Follow the below instructions to use the system:
- Choose the appropriate model nomenclature based on your requirements.
- Mount the system on the wall using the selected enclosure style.
- Connect the power supply board to 120/230VAC 50/60Hz input.
- Configure the system for failsafe / failsecure operation at either 12 or 24 VDC.
- Connect the access control inputs and outputs to the AMAG M2150 or M4000 series controllers.
- Connect the auxiliary outputs to other devices as required.
- Monitor the system for power, batteries, and sixteen outputs.
- In case of faults or tampering, refer to the user manual for troubleshooting instructions.
Overview
These ProWire Unified Power wall mount models are single and dual voltage
access power systems, precision wired for AMAG M2150 or M4000 series
controllers. ProWire enables the specification and installation of
standardized access power equipment across an enterprise for uniform
operation, maintenance and servicing.
The two C8 or M8 control modules provide sixteen access control inputs capable
of voltage or dry contact activation, and sixteen outputs programmable for
failsafe / failsecure operation at either 12 or 24 VDC and controlled by the
power supply fire alarm interface. The two D8 modules provide sixteen
auxiliary outputs. In these dual voltage systems, each output is configurable
for 12 or 24VDC operation.
ProWire Unified Power enclosures are painted steel with removable backplate,
lock, keys and and tamper switch and come 100% factory tested – ready for
final panel installation and field wire termination.
Product Features
- Guarantees uniform installations across an enterprise
- Pre-installed wire harness for panel power, lock control, faults and tamper switch
- Point-to-point wiring; labeled, color-coded, twisted pair, shielded communication
- Tie wrap or wire duct cable management options
- Managed systems monitor power, batteries and sixteen outputs
- UL294, ULC S319 joint LSP / AMAG integrated listing
Enclosure Styles
E6A1, E8A – Wallmount
Model Nomenclature
*Model Number| Model Wiring Options| ****
System Type
| Distributed Outputs| Enclosure / Cable Mgmt
---|---|---|---|---
T16-A| T16-C| P16-A| P16-C| Auxiliary and Control|
H x W x D (inches)
Dual Voltage 12A/12V and 10A/24V – medium enclosure
FPO150/250-2C82D8E6A1/P16-A| T16-A| T16-C| P16-A| P16-C| Standard| 16 auxiliary, 16 lock control| E6A1
30 x 23 x 6.5
Tie Wrap / Panduit
---|---|---|---|---|---|---|---
FPO150/250-2D82M8NL4E6A1/P16-A| T16-A| T16-C| P16-A| P16-C| Networked| 16
auxiliary, 16 managed
Dual Voltage 12A/12V and 10A/24V – large enclosure
FPO150/250-2C82D8E8A/P16-A| T16-A| T16-C| P16-A| P16-C| Standard| 16 auxiliary, 16 lock control| E8A
36 x 30 x 6.5
Tie Wrap / Panduit
---|---|---|---|---|---|---|---
FPO150/250-2D82M8NL4E8A/P16-A| T16-A| T16-C| P16-A| P16-C| Networked| 16
auxiliary, 16 managed
Model wiring option “P16-A” calls out A wired Panduit. Modify model number to order other options, i.e., FPO150/250-2C82D8E8A/T16-A (A wired tie wrap )
System Specifications
Power Supplies | FPO150 | Power supply board 12A/12V, 150W |
---|---|---|
FPO250 | Power supply board 10A/24V, 250W | |
Input 120/230VAC 50/60Hz |
voltage 452 Watts (3.77A) Overload and short circuit protection
Over temperature protection
Polarized AC power supply disconnect
Battery Charging| | Independent built-in charger for sealed lead-acid or gel type batteries Microprocessor dual rate charging of 12 or 24V battery sets Automatic switchover to standby battery when AC fails
Zero voltage drop when switched over to battery backup
Supervision| | AC Fault (form “C” contacts) System Fault (form “C” contacts)
System Fault conditions: Low or no battery | short to earth ground | power supply failure
Distribution Modules| D8 (X2)| 16 auxiliary outputs, fused at 3A
per output
| C8 (X2)| 16 relay lock control outputs, fused at 3A per output
| M8 (X2)| 16 relay managed outputs, fused at 3A per output
Network Management| NL4| Four port module. Monitors and reports
power supply status. Tests and reports battery health status.
| M8| Monitors eight (8) individual outputs. Remote reset each output.
Set window thresholds for voltage & current.
Enclosure Options| E6A1| Size: 30.00H x 23.00W x 6.50D in. (76.20 x
58.12 x 16.51 cm) | Weight: 47 lbs.
| E8A| Size: 36.00H x 30.00W x 6.50D in. (91.44 x 76.20 x 16.50 cm) |
Weight: 70 lbs.
Wiring Suffix| T16-A | P16-A| T = Tie Wrap P = Panduit
16 = Door count A = 8DBC (X2)| | | |
| T16-C | P16-C| T = Tie Wrap P = Panduit 16 = Door count
C = M4000 (X4)| | ****
| | ****
Regulatory Compliance| UL / ULC| UL294, ULC S319
| CSA / FCC| CSA C22.2 #107.1 | FCC Part 15, CSFM
Board Locations/Wiring Examples
LifeSafety Power
10027 S. 51st Street, Suite 102 Phoenix, AZ 85044 USA
888-577-2898
info1@lifesafetypower.com
P01-1017A 01/22
LifeSafety Power warrants to the original purchaser only that all products will be free from defects in material or workmanship at time of shipment. This warranty is non-transferable. Our obligation under this warranty is limited to repair or replacement, at the sole discretion of LifeSafety Power, of products that are defective in material or workmanship at the time of shipment provided they were used within the specified ratings and installed in accordance with accepted engineering practices. Products in the Unified Wired Systems Classification will be wired to the LifeSafety Power description of operation unless otherwise stated. At the time of installation it is the obligation of the purchaser or final installer to verify that all wired terminations provide the desired operation. In no event shall LifeSafety Power be responsible for any special, incidental or consequential damages even if LifeSafety Power has been advised of the possibility of such damages. Customer hereby agrees to indemnify LifeSafety Power for and hold LifeSafety Power harmless from and against any and all loss, cost or expense (including reasonable attorneys’ fees) directly or indirectly related to any claim with respect to Unified Wired™ systems classification products except to the extent any such claim shall result from the gross negligence or willful misconduct of LifeSafety Power
www.lifesafetypower.com
January 2022
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>