RURIS GE9000ATS Power Generator User Manual

October 30, 2023
RURIS

GE9000ATS Power Generator
User Manual

INTRODUCTION

Dear Customers,
Thank you for the decision to buy a RURIS product and for the trust placed in our company! RURIS has been on the market since 1993 and, all this time, it has become a strong brand, which has built its reputation by keeping its promises, but also by continuous  investments meant to help customers with reliable, efficient and quality solutions.
We are confident you will appreciate our product and enjoy its performance for a long time. RURIS does not only offer its customers equipment, but complete solutions. An important element in the relationship with the customer is sale and after sale counselling and RURIS customers have at their disposal a whole network of partner stores and service points.
To enjoy the product you bought, please read carefully the user’s manual and pay attention to the provided information. Following the instructions will guarantee a long-term use.
The RURIS company works continuously to develop its products and, therefore, reserves the right to change, among other things, their shape and performance, with no obligation for prior notice.
Thank you once again for choosing RURIS products!
Customer information and support:
Telephone: 0351.820.105
e-mail: info@ruris.ro

SAFETY INSTRUCTIONS

This user manual is considered a permanent part of the power generator and must remain with the power generator in the event of resale.
Assembling and major repair work shall only be carried out by specially trained personnel.
SAFETY LABELS
These labels warn you of potential hazards that can cause serious injury. Read them carefully.

| Read the user manual
---|---
| Connect to the ground
| Danger
| Danger of electric shock
| Careful! High temperature
| Danger of carbon monoxide poisoning

SAFETY INFORMATION
Power generators are designed to provide safe and reliable service if used according to the instructions. Read and understand this user manual before using the power generator. You can help prevent accidents by becoming familiar with power generator controls and following safety operating procedures.
Liability of the operator
It is necessary to know how to stop the power generator as quickly as possible in case of emergency.

  • It is necessary to understand the use of all power generator controls, output containers and connections.
  • Make sure the person using the power generator receives proper instructions. Do not let children operate the power generator without parental supervision.

Hazards due to inhalation of carbon monoxide

  • Exhaust gases contain harmful carbon monoxide, a colorless and odorless gas. Inhaling it can cause unconsciousness and even death.
  • If you use the power generator in a confined or even partially enclosed area, the air you breathe may contain a dangerous amount of exhaust gases. To avoid accumulation of exhaust fumes, ensure adequate ventilation.

Electrical shock hazards

  • The power generator produces enough electricity to cause serious shock or electrocution if used improperly.
  • Using a generator or electrical appliance in wet conditions, such as rain, snow or near a swimming pool, sprinkler system, if hands are wet, could cause electric shock. Keep the power generator dry.
  • If the power generator is stored outdoors without weather protection, check all electrical components on the control panel before each use. Moisture or ice can cause electrical components to malfunction or short circuit which could result in electric shock.
  • Connect to the electrical system belonging to a building only if an isolation switch has been installed by a qualified electrician.
  • Avoid spilling fuel on the generator during refueling.
  • Always supply power to the generator after shutdown.
  • Smoking while refueling or refueling near sources of fire is prohibited.
  • When using the power generator, you are required to use protective gloves to protect your hands from high temperatures.

GENERAL PRESENTATION OF THE MACHINE

  1. Fuel cap
  2. Fuel indicator
  3. 230V single-phase outlets
  4. ATS connector
  5. Transport handle
  6. Battery
  7. Oil dipstick
  8. Transport wheel
  9. Starter
  10. Air filter
  11. Fuel tap
  12. Shock flap
  13. Metal frame

3. 1 ASSEMBLY GUIDE

  1. Mount the transport handles (fig. 1)
  2. Mount the shaft and transport wheels on the power generator frame (fig. 2 and 3)
  3. Fix the support legs of the power generator using the screws provided (fig. 4).
  4. Make sure the battery terminals are properly mounted.

TECHNICAL DATA

Engine General Engine
Engine type 4 strokes
Engine power 15 hp
Cylinder capacity 445 cc
Ignition system Electronic
Starting Electric with battery
Fuel Unleaded gasoline
Fuel tank capacity 25 L
Engine oil bath capacity 1.1 L
Average fuel consumption < 370 (grams/kW/h)
Maximum generator power 7500 W
Generator nominal power 7000 W
Working frequency 50 Hz
Rated power 31
Number of outlets 2
Stator, rotor winding Copper
Output voltage DC
Output voltage AC 220 V
ATS YES
AVR YES
Fuse Standard equipment
Frame type Industrial
Transport wheels YES
Net weight 80 kg

Ground terminal
The ground terminal of the generator is connected to the frame of the power generator, the non-conductive metal parts of the generator and the ground terminals of each outlet. Before using the grounding terminal, consult a qualified electrical inspector or local agency having jurisdiction for local codes or ordinances that apply to the use of the power generator.

FUEL AND OIL SUPPLY

5.1 OIL SUPPLY
Engine oil is a major factor affecting engine performance and engine life. Non-detergent oils and two-stroke engine oil will damage the engine and are not recommended.
Check the oil level BEFORE EACH USE by placing the power generator on a level surface with the engine off.
CAREFUL! The power generator does not come with oil in the engine.
Fill the engine bath with RURIS 4T-MAX engine oil or an API classification oil: CI-4/SL or higher, up to the top of the filler hole (see technical data table).
In the cold season of the year, it is recommended to use the oil RURIS 4T- WINTER GT SAE 10W-40 API: CI-4/SL.

  1. Remove the oil filter cap and clean the dipstick.
  2. Check the oil level by inserting the dipstick into the filler hole without screwing it in.
  3. If the level is low, fill to the top of the filler hole with the recommended oil.
  4. Reposition the dipstick again.

5.2 FUEL SUPPLY

  1. Remove the fuel tank cap and check the level.
  2. Refuel when the level is low.
    Do not exceed the angle of the filter.

WARNING!

  • Gasoline is highly flammable and explosive under certain conditions.
  • Refuel in a well ventilated area with the engine off. Do not smoke or allow flames or sparks in the area where the engine is fueled or where gasoline is stored.
  • Do not fill the fuel tank (there must be no fuel in the filler neck). After refueling, check the tank cap. It must be closed properly.
  • Be careful not to spill fuel when refueling. Spilled fuel or fuel vapors may ignite. If you spill fuel, make sure the area is dry before starting the engine.
  • Avoid repeated or prolonged contact with the skin or breathing gasoline vapors.
  • Starting the engine with repeated knocks or noise can cause engine damage.

It is not recommended to run the engine with knocks or noise, as it may cause damage to the parts or even the machine, this is not covered by the warranty (it is considered incorrect use).
Use quality fuel from authorized fuel stations.
Fill with the best quality UNLEADED GASOLINE, using a metal funnel, in open areas and away from sources of fire or sparks that could cause a fire.
WARNING!
Do not refuel on the ground or near plants, as you risk damaging the environment.
5.3 SAFETY FUEL HANDLING
**CAUTION
This fuel is extremely flammable. Do not smoke or bring flame or sparks near fuel.
IMPORTANT**

  1. Stop the engine before refueling.
  2. Using the wrong oil can lead to clogging of the spark plug, clogging of the muffler or of the piston rings.
  3. Move at least 3 meters away from the fuel point before starting the engine.
  4. Using an improper fuel will cause severe damage to the internal parts of the engine in a short time.

PRE-OPERATION CHECKS

  1. Check that all screws are tight and adjust if necessary.

  2. Topping up the oil.
    – Fill the engine oil bath with RURIS 4T-MAX lubricating oil.
    – Place the power generator on a flat surface while refueling.
    – To check the oil level use the oil dipstick, the oil must be at maximum level.
    – Check for oil leaks.

  3. Clean the unit of dust and dirt, especially the air filter.

COMMISSIONING

7.1 START – UP

  • If the power generator you start, operates abnormally, becomes slow or stops suddenly, stop it immediately. Disconnect the equipment and established if the problem is the equipment or if it was exceeded the capacity rated load of the generator.
  • Ensure that the rated load capacity of the tool or appliance does not exceed the power of the generator. Never exceed the maximum power of the generator. Power levels between nominal and maximum can be used for a maximum of 30 minutes.

WARNING!

  • If the power generator needs to be connected to the household power supply, only electrical technicians will make the connection. Any improper connection may result in a fire hazard or damage to the power generator while the power generator is connected to the equipment.
  • The overload protector will be automatically triggered when the circuit is overloaded.
    Always take the following steps to keep your power generator in good condition.
  1. Always connect the power generator to the ground to prevent any kind of hazard.
  2. If the power generator is to provide electricity for the above tasks, be sure to connect
    them to the power source.

Starting the generator:

  1. Turn the fuel tap lever to the ON position

  2. Move the shock flap lever to the CLOSED (OFF) position. Careful!
    Do not use the shock when the engine is at high temperature.

  3. Turn the ignition to the ON position.

  4. Pull the starter handle smoothly until resistance is felt, then pull steadily Do not let the starter handle return suddenly toward the engine. Return gently to prevent damage to the handle or cover. For automatic start, turn the ignition key to the START position, then release it.

  5. While the engine is warming up, slowly push the shock flap lever to the OPEN (ON) position.

Careful!
If the device is not used regularly, make sure to turn on the power generator and use it for at least 2 hours every 30 days. This will keep the battery charged.
7.2 STOPPING THE GENERATOR

  1. Turn the ignition switch to the OFF position.  
  2. Turn the fuel tap lever to the OFF position.

EMISSION CONTROL SYSTEM
Combustion can generate pollutants such as CO, nitrogen oxides, hydrocarbons, which can contaminate environment in the case in which a large amount of them is released in the air. Among these, CO is a colorless, odorless and toxic gas. It is very important to control them.

Description Power Symbols Examples
Start Efficiency Electrical device

Incandescent lamp
Heating device| x 1| x 1| Incandescent lamp | Incandescent lamp
100W| 100V A (W)| 100V A (W)
Fluorescent lamp| x2| x 1.5| Fluorescent lamp| 40W
fluorescent lamp| 80V A (W)| 60V A (W)
Device of start-up| x 3 – 5| x2| Refrigerator
Electric fan| Refrigerator
150 W| 450-750VA (W)| 300V A (w)

The table above provides reference information for connecting electrical appliances to the generator.

MAINTENANCE

Proper maintenance is the responsibility of the owner. See maintenance plan for specific maintenance. Note that this list is made under the general conditions under which the gasoline engine is used. If it is continuously used under heavy load or under high temperature with improper humidity or dusty environment, maintenance should be performed more frequently.
Replacement of spare parts
It is recommended to use only original spare parts or their equivalent. Substitution with inferior quality replacement parts may affect the performance of the emission control system.
Unauthorized changes
Modifications or changes to the emission control system may cause emissions to exceed legal specifications. Unauthorized modifications or changes include:

  1. Removal or replacement of any spare part in the intake or exhaust system.
  2. Modifying or removing connections for the speed control system that causes the gasoline engine to operate beyond the parameter settings.

Emissions may be adversely affected if:

  1. Black smoke is emitted or fuel consumption is high.
  2. During the operation of the engine, failures occur in the carburetor or in the muffler.
  3. Ignition occurs earlier or later than normal.

Periodic inspection and adjustment can keep your gasoline engine performing well and extending its life. Intervals and maintenance items are presented in the following table:
MAINTENANCE TABLE

  1. Perform maintenance more often when using the machine in dusty areas.
    Interval
    Item| With every  use| After 20h or after the first month| After 50h or 3 months| After 100h or 6 months| After 300h or one year
    ---|---|---|---|---|---
    Engine oil check| A| | | |
    Engine oil replacement| | A| | A|
    Air filter check| A| | | |
    Air filter cleaning| | | A| |
    Air filter cover cleaning| | | | A|
    Battery electrolyte level check| A| | | |
    Spark plug cleaning| | | | A|
    Checking and adjusting valve play| | | | | 0(x)
    Battery| Replacement if necessary
    Fuel tank| Replacement after 3 years(x)
  2. O(x); (x) -These parts of the maintenance process must be carried out at an authorizedRURIS service.
  3. For professional commercial use, record machine operating hours to determine proper maintenance.

WARNING! If you do not perform maintenance correctly or if you do not solve a problem before operation, you can cause a malfunction that can cause you to be injured or killed.
Always follow the maintenance and inspection recommendations and schedule in this manual.
WARNING! Extended and repeated exposure to lubricants can cause skin reactions.
Skin is cleaned and rinsed immediately after exposure using soap and clean water.
AIR FILTER MAINTENANCE
A clogged air filter (impregnated with impurities) will decrease the flow of air through the carburetor. Always perform periodic air filter maintenance. Frequent maintenance is necessary when the power generator is exposed to highly dusty areas.
WARNING
Do not clean the filter element using gasoline or low-burning point cleaner.
Do not start the engine without an air filter. Otherwise, dirty air can enter the engine, shortening its life.

  1. Remove the air filter cover. Remove the filter element.
  2. Clean the filter element then dry it completely in a natural environment.
  3. Refit the filter element and replace the cover.

CLEANING THE DECANTER CUP
Turn off the fuel tap, remove the decanter cup and O-ring, and clean the decanter cup.
Reassemble the components after drying them completely. Open the fuel tap to check for leaks. CAREFUL!

  • Gasoline is extremely flammable and explosive. Remove all smoke and fire and maintain good ventilation.
  • Check that the decanter cup does not leak after reassembly. Store the machine in a dry and clean environment.

CHANGING ENGINE OIL
To ensure quick and complete draining of the engine oil, change the oil when the engine is warm.

  1. Remove the oil dipstick and drain plug to drain the lubricant.
  2. Refit and tighten the drain plug.
  3. Top up with the recommended lubricant and check the level.
  4. Reinstall the oil dipstick.

The capacity of the oil bath of the generator is 1.1l (see technical data) Wash your hands with soap and water after changing the used oil.
It is recommended to dispose of used engine oil in a manner compatible with environmental protection regulations. We suggest disposal in a sealed container at your local service station or recycling centre. Do not throw it in the trash, do not pour it on the ground or into the waste water network.
SPARK PLUG MAINTENANCE Do not use the spark plug beyond the permitted thermal limits. To ensure the proper operation of the machine, the spark plugs must be properly spaced and free of sediment.

  1. Remove or replace the spark plug using the special wrench.

  2. Visually check the spark plug. Replace any spark plug that shows wear or has a cracked/defective dielectric. In the case of reuse, cleaning with a wire brush is necessary.
    CAREFUL! Do not touch the spark plug shortly after the machine has been stopped as it is extremely hot.

  3. Measure the gap using a tape measure. Pull the electrode if necessary to adjust. 0.70.8mm is the appropriate gap range.

  4. Check that the spark plug mounting washer is in proper condition.

  5. Screw the spark plug by hand as far as it will go, then tighten with the special wrench. Keep the gasket firmly in place.

CAREFUL! When installing a new spark plug, it will be tightened half a turn by fixing the gasket accordingly. When installing a used spark plug, it will be tightened 1/8-1/4 after the gasket is properly secured.

  • The spark plug must be tight. Otherwise, it will become extremely hot and cause damage to the machine.
  • Use the recommended spark plug. Otherwise, the machine may be damaged.

STORAGE AND TRANSPORT

When transporting the power generator, turn the ignition switch and fuel tap to the “OFF” position. Keep the power generator in a horizontal position to prevent fuel leakage. Fuel vapors or spilled fuel can ignite.

  1. Transport
    Do not transport the generator unless the fuel tap is turned off and the engine is cold.
    CAREFUL! Do not tilt the power generator. Otherwise, a fire may occur due to leakage or volatilization of fuel.

  2. Storage

Check the following conditions in case of long-term storage of the power generator:

  • The storage location does not have high humidity or dust.
  • The fuel is drained.

WARNING! To prevent gasoline from burning and exploding, fire and smoke are strictly prohibited.
a) Turn the fuel tap to the “OFF” position, remove and empty the decanter.
b) Open the fuel tap, empty the fuel tank into a suitable empty container.
c) Refit the decanter, tighten and secure it properly.
d) Loosen the carburetor drain screw, drain the fuel from the carburetor into a suitable empty container.

  • Replace the lubricant.
  • Remove the spark plug. Pour 5 ml of clean lubricant into the cylinder. Turn over the power generator so that the lubricant is distributed evenly. Refit the spark plug.
  • Operate the starter handle until resistance is felt.
  • Cover the generator to protect it from dust.

INSTRUCTIONS FOR USING THE ATS SYSTEM

10.1 ATS INSTRUCTIONS
The ATS system is designed for starting the power generator if the supply with energy from the source the main one was turned off.
When the power source is off , the generator will start in 2-6 seconds and will provide energy for consumers . When the power supply is turned on, the ATS system will automatically switch to the main power source and then it will stop the power generator in 2-6 seconds.

  1. This system uses basic SCM technique and digital technique to control and manage the automatic work system.
  2. Easy installation and operation
  3. Automatic operation, without intervention on the generator. When the power transfer is interrupted, the system will log the errors and prompt the operator to inspect and reconfigure the system. Main network power supply and generator power can work at the same time.
  4. The power generator is equipped with a charger that keeps its battery charged.

10.2 OPERATING STEPS
Use the cable to connect the ATS box to the generator control panel.

  1. Automatic position setup
    By pressing the AUTO button, the AUTO indicator light will turn on, the ATS system will work automatically.

  2. Operation of the ATS system
    When the ATS system is working automatically, if the main power source is off, the ATS system will automatically open the air damper control (shock damper) and start the generator in 2 seconds, let the generator run for 5 seconds, then the system will switch the load to the generator power source.

  3. Starting the ATS system 3 times
    When the generator cannot start properly, the ATS system will attempt to start the generator 3 times consecutively as follows:
    Main network power supply off → power generator starts for 3 seconds first time → start unsuccessful, waits 5 seconds → power generator starts for 4 seconds → start unsuccessful, waits 5 seconds → power generator starts for 5 seconds third time.
    Note: When the generator can not start after 3 attempts, then the indicator light “ERROR” will light up.

  4. Stopping the power generator
    When the main network power is restarted, the ATS system will switch to the main power supply network.

  5. Manual start-up
    If you do not want the ATS to operate automatically, turn the switch to the “MANUAL” position.

  6. Automatic shock flap control
    If the generator is equipped with automatic shock flap control, when the generator is started, the ATS system will start the shock flap. After the generator starts, it will open the shock flap for proper operation of the power generator.

10.3 BATTERY MAINTENANCE
The ATS system will automatically charge the battery, the charging power is 2A.
10.4 ATS NETWORK CONNECTION DIAGRAM 10. 5 ELECTRICAL DIAGRAM
Single-phase, single-voltage wiring diagram:

Remarks

  1. The power of the ATS system must be greater than the loading power.
  2. You must add an air breaker to protect the ATS system, when you connect the power wire from the main power source to the ATS system.
  3. Start the generator in the “OFF” position, then you can use the “AUTO” mode for the automatic operation of the system.
  4. Place the air switch in the “ON” position when using the ATS system.
  5. Only the electrician can open the box for inspection and repair, there is danger of electric shock.
  6. Commissioning and installation of the ATS system is done by qualified personnel

DECLARATIONS OF CONFORMITY

DECLARATION OF CONFORMITY CE
Manufacturer: SC RURIS IMPEX SRL
Blvd. Decebal, no. 111, Administrative Building, Craiova, Dolj, Romania
Phone. 0351 464 632, www.ruris.ro, info@ruris.ro
Authorized representative: Eng. Stroe Marius Catalin – General Manager
Authorized person for the technical file: Eng. Alexandru Radoi – Production Design Director
Description of the machine: The POWER GENERATOR ensures a continuous supply of electricity, being driven by a 4-stroke engine and equipped with an electronic ignition system.
Product: THE POWER GENERATOR
Product serial number: from xx GE9000ATS 0001 to xx GE9000ATS 9999 (where xx represents the last two digits of the year of manufacture)
Type: RURIS Power: 15 hp
Power: 15 hp
Engine: thermal, 4-stroke, unleaded gasoline
Model: R-Power GE 9000ATS
Nominal generator   power: 7000 W
Working frequency: 50Hz
We, SC RURIS IMPEX SRL Craiova, manufacturer, in accordance with HG 1029/2008 – regarding the conditions for the introduction of cars on the market, Directive 2006/42/EC – cars; safety and security requirements , Standard EN ISO 12100:2010 – Machinery. Security, Directive 2014/30/EU on electromagnetic compatibility (HG487/2016 on electromagnetic compatibility, updated 2019), Directive 2014/35/EU, HG 409/2016 – on lowvoltage equipment, EU Regulation 2016/1628 (amended by EU Regulation 2018/989) – establishing measures limiting gaseous emissions and polluting particles from engines and HG 467/2018 regarding the enforcement measures of the aforementioned Regulation, we have certified the product’s compliance with the specified standards and declare that it complies with the main safety and security requirements.
The undersigned Stroe Catalin, the manufacturer’s representative, declares on his own responsibility that the product is in accordance with the following European standards and directives:

  • SR EN ISO 12100: 2011 / EN ISO 12100:2010 – Security cars . Basic concepts , principles general design . Basic terminology , methodology . pRINCIPLES technically
  • SR EN ISO 8528-13 : 2016/ EN ISO 8528-13:2016– Groups alternating current generators driven by motors with combustion intern with motion alternative . part 13: Security
  • ISO 2261:1994 – Internal combustion engines – Manually operated control devices – Standard Motion Directive
  • SR EN ISO 13732-1:2009/ EN ISO 13732-1:2008 – Ergonomics of the thermal environment. Methods of assessment of contact with surfaces. Part 1: Warm surfaces
  • SR EN ISO 11688-1:2010/ EN ISO 11688-1:2009 – Acoustics. Practical recommendations for the design of machines and equipment with low noise. Part 1: Planning
  • SR EN ISO 4871:2010/ EN ISO 4871:2009- Acoustics. Declaration and verification of noise emission values of machines and equipment
  • SR EN 60204-1:2007/AC:2013/ EN 60204-1:2006/corrigendum Feb. 2010 – Car safety. Electrical equipment of cars. Part 1. General requirements
  • IEC 60364-4-41:2005 – Low voltage electrical installations. Part 4-41: Safeguards to ensure security. Protection against electric shocks
  • SR HD 60364-5-54:2012/ IEC 60364-5-54:2011 – Low voltage electrical installations. Part 554: Selection and installation of electrical equipment. Grounding installations and protective conductors
  • SR EN 60034-1:2011/ IEC 60034-1:2010 – Rotating electrical machines. Part 1: Ratings and performance characteristics
  • SR EN 61310-1 : 2008/ EN 61310-1:2008 – Security cars . Indication , marking and handling . part 1: Requirements for mark visual , acoustic and tactile
  • SR EN 55012:2008/A1:2010/ EN 55012:2007/A1:2009 – Vehicles, boats and internal combustion engines. Characteristics of radioelectric disturbances. Limits and measurement methods for the protection of outdoor receivers
  • SR EN 55014-1:2017; SR EN ISO 55014-2:2015 – Electromagnetic compatibility
  • SR EN 61000-3-2/2014; SR EN ISO 61000-3-3/2013 – Electromagnetic compatibility
  • Directive 2000/14/EC (amended by Directive 2005/88/EC) – Noise emissions in the outdoor environment
  • Directive 2006/42/EC – regarding machines – placing machines on the market
  • Direction 2014/30/EU – on electromagnetic compatibility (HG 487/2016 on electromagnetic compatibility, updated 2019);
  • Directive 2014/35/EU, HG 409/2016 – regarding low-voltage equipment
  • EU Regulation 2016/1628 (amended by EU Regulation 2018/989) – establishing measures to limit gaseous emissions and polluting particles from engines

Other Standards or specifications used:

  • SR EN ISO 9001 – Quality Management System
  • SR EN ISO 14001 – Environmental Management System
  • SR ISO 45001:2018 – Occupational Health and Safety Management System.

MARKING AND LABELING OF ENGINES
Spark ignition gasoline engines received and used on RURIS equipment and machines, according to EU Regulation 2016/1628 (amended by EU Regulation 2018/989) and HG 467/2018 are marked with:

  • Manufacturer’s brand and name: CDGM Co. LTD .
  • Type: BS192F/P
  • Type approval number obtained by the specialized manufacturer: e242016/16282017/656SYB1/P008600
  • Engine identification number – unique number.
  • Concept General Engine

Note: the technical documentation is owned by the manufacturer.
Clarification: This declaration is in accordance with the original.
Validity period: 10 years from the date of approval.
Place and date of issue: Craiova, 2022
Year of application of the CE marking: 2022
No. reg: 1305/07.11.2022
Authorized person and signature

Ing. Stroe Marius Catalin
General Manager of Ruris Impex SRL

DECLARATION OF CONFORMITY EC
Manufacturer : SC RURIS IMPEX SRL
Blvd. _ Decebal , no. 111, Building Administration , Craiova, Dolj , Romania
Tel. 0351 464 632, www.ruris.ro, info@ruris.ro
Representative authorized : Eng . Stroe Marius Catalin – General Manager
The person authorized for technical file : Eng Alexandru Radoi – Production Design Director
Description of the machine: GENERATOR ensures continuous supply of electricity, being driven by a 4-stroke engine and equipped with an electronic ignition system
Product: GENERATOR
Product serial number: from xx GE9000ATS 0001 to xx GE9000ATS 9999 (where xx represents the last two digits of the year of manufacture)
Type: RURIS
Power: 15 HP
Engine : thermal, 4-stroke, unleaded gasoline
Model: R-Power GE 9000ATS
Generator nominal power: 7000 W
Working frequency: 50Hz
Measured sound power level: 94dB(A) Guaranteed sound power level: 97 dB(A) The acoustic power level is certified by Force Technology thorugh certificate no. DANAK1002838 from 22.12.2022, in accordance with the provisions of Directive 2000/14/CE amended by Directive 2005/88/CE and SR EN ISO 3744:2011.
Noi, SC RURIS IMPEX SRL Craiova in calitate de producator, in conformitate cu Directiva We, SC RURIS IMPEX SRL Craiova as a manufacturer, in accordance with Directive 2000/14/EC (amended by Directive 2005/88/EC), HG 1756/2006 – on limiting the level of noise emissions in the environment produced by equipment intended for use outside the buildings, we have verified and certified the conformity of the product with the specified standards and declare that it complies with the main requirements.
The undersigned Stroe Catalin, the manufacturer’s representative, declares on his own responsibility that the product is in accordance with the following European standards and directives:

  • Directive 2000/14/EC (amended by Directive 2005/88/EC) – Noise emissions in the outdoor environment
  • SR EN ISO 3744:2011 – Acoustics. Determination of sound power levels emitted by noise sources using sound pressure
  • Directive 2006/42/EC – regarding machines – placing machines on the market
  • Directive 2014/30/EU on electromagnetic compatibility (HG 487/2016 on electromagnetic compatibility, updated 2019);
  • EU Regulation 2016/1628 (amended by EU Regulation 2018/989) – establishing measures to limit gaseous emissions and polluting particles from engines

Other Standards or specifications used:

  • SR EN ISO 9001 – Quality Management System
  • SR EN ISO 14001 – Environmental Management System
  • SR ISO 45001:2018 – Occupational Health and Safety Management System.

Note: the technical documentation is owned by the manufacturer.
Clarification: This declaration is in accordance with the original.
Validity period: 10 years from the date of approval.
Place and date of issue: Craiova, 2022
Year of application of the CE marking: 2022
No. reg: 1478/ 29.12.2022
Authorized person and signature:

Ing. Stroe Marius Catalin
General Manager of SC RURIS
IMPEX SRL