KLEIN TOOLS NCVT-3P Dual-Range Non-Contact Voltage Tester with Flashlight Instructions
- June 4, 2024
- KLEIN TOOLS
Table of Contents
NCVT-3P Dual-Range Non-Contact Voltage Tester with Flashlight
Instructions Manual
- NCV Power On/Off Button
- Flashlight Power On/Off Button
- Power On/Mode LEDs
- Voltage Detection LEDs (Inside Tip)
- Non-Contact Tip
- Flashlight
- Pocket Clip
- O-ring Seal
- Battery Cap
- 2x AAA Batteries (Included)
NOTE: There are no user-serviceable parts inside the tester.
- Detects AC voltage from 12 to 1000V with visual & audible indicators
- Flashlights may be used independently of the NCVT
DURABILITY
Ingress Protection | IP67 | |
---|---|---|
Drop Protection | 6.6 ft. |
(2 m)
Safety Rating| | CAT IV
1000V
SYMBOLS ON TESTER
Warning – Risk of electric shock
Risk of danger. Important information: It is important that users of this
tester read, understand, and follow all warnings, cautions, safety
information, and instructions in this manual before operating or servicing
this tester. Failure to follow instructions could result in death or serious
injury.
Double insulated
Read instructions
Conforms with European Economic Area directives.
UKCA:
UK Conformity Assessment
This product has been independently tested by Intertek and meets applicable
published standards.
Measurements were performed at the source of low-voltage installation and
outside lines.
GENERAL SPECIFICATIONS
The Klein Tools NCVT-3P is a dual-range non-contact voltage tester (NCVT) with a flashlight. It can detect voltage from 70 to 1000V AC (Mode 1), or from 12 to 1000V AC (Mode 2) for low voltage and higher sensitivity.
-
Environment: Indoor or outdoor
-
Measurement Range: Mode 1: 70 to 1000V AC
Mode 2: 12 to 1000V AC -
Frequency Range: 50 to 500 Hz
-
Batteries: 2x AAA 1.5V Alkaline
-
Operating and Storage Altitude: Up to 6562 ft. (2000 m)
-
Operating and Storage Temp: 14° to 122°F (-10° to 50°C)
-
Relative Humidity: <95% non-condensing
-
Dimensions: 6.0″ x 0.96″ x 1.16″ (152 x 24 x 29 mm)
-
Weight: 2.5 oz. (72 g) including batteries
-
Pollution degree: 2
-
Safety Rating: CAT IV 1000V AC
-
Drop Protection: 6.6 ft. (2 m)
-
Ingress Protection: IP67
-
Standards: EN61010-1:2010, EN61010-2-030:2010, EN61326-1:2013, EN61326-2-2:2013.
Conforms to UL STD. 61010-1, 61010-2-030
Certified to CSA STD. C22.2 No. 61010-1, 61010-2-030. 5001748
Specifications are subject to change.
FUNCTION BUTTONS
NCV POWER ON/OFF BUTTON 1
To activate the Non-Contact Voltage Testing feature, press and release the NCV Power button 1. All LEDs will illuminate during the self-test, then the tester will emit a single beep, one of the Powers ON LEDs 3 will illuminate 3 indicating which NCVT mode is active (see OPERATING INSTRUCTIONS), and a green light will illuminate in the tip 4. To power off the tester, press and hold the NCV Power button 1. The tester will emit a double beep.
NOTE: The tester will automatically power OFF following 4 minutes of inactivity to conserve battery life.
FLASHLIGHT ON/OFF BUTTON 2
Press the Flashlight Power Button 2 to turn on the flashlight. Press again to
turn off the flashlight.
NOTE: The flashlight will automatically power off after 20 minutes to
conserve battery life
WARNINGS
To ensure the safe operation and service of the tester, follow these
instructions.
Failure to observe these warnings can result in severe injury or death.
- Risk of electric shock and burn. Contact with live circuits could result in death or serious injury.
- Use caution with voltages above 25V AC as a shock hazard may exist.
- A blinking LED or a steadily illuminated LED in the tip and audible beeps indicate the presence of voltage. If no indication, the voltage could still be present.
- Before and after each use, verify operation by testing a known working circuit that is within the rating of this unit.
- Never assume neutral or ground wires are de-energized. Neutrals in multi-wire branch circuits may be energized when disconnected and must be retested before handling.
- The tester WILL NOT detect voltage if:
- The wire is shielded.
- The operator is not grounded or is otherwise isolated from effective earth ground.
- The voltage is DC.
- The tester MAY NOT detect voltage if:
- The user is not holding the tester.
- The user is insulated from the tester with a glove or other materials.
- The wire is partially buried or in a grounded metal conduit.
- The tester is at a distance from the voltage source.
- The field created by the voltage source is being blocked, dampened, or otherwise interfered with.
- The frequency of the voltage is not a perfect sine wave between 50 and 500Hz.
- The tester is outside of operating conditions (listed in the Specifications section).
- The operation may be affected by differences in socket design and insulation thickness and type; the tester may not be compatible with some types of standard or tamper-resistant (TR) electrical outlets.
- In bright light conditions, the LED visual indicators will be less visible.
- When powered-ON, one of the “power-ON” LEDs will be illuminated, and a green light will illuminate the tip. DO NOT USE TESTER UNLESS ONE OF THE “POWER-ON” LEDs IS ILLUMINATED.
- Do not use if the tester appears damaged or is not operating properly. If in doubt, replace the tester.
- Do not apply more than the rated voltage as marked on the tester (1000V).
- Do not apply to uninsulated hazardous live conductors.
- Detection above 70V AC in Mode 1, or above 12V AC in Mode 2 is specified under “normal” conditions as detailed below. The tester may detect at a different threshold at different conditions, or may not detect at all unless:
- The tip of the tester is within 0.25″ (6 mm) of an AC voltage source radiating unimpeded.
- The user is holding the body of the tester with his or her bare hand.
- The user is standing on or connected to earth ground.
- The air humidity is nominal (50% relative humidity – non-condensing).
- The tester is held still.
- Always wear approved eye protection.
- Comply with local and national safety requirements.
- If this product is used in a manner not specified by the manufacturer, the protection provided by the product may be affected.
****CAUTION
- DO NOT attempt to repair this tester. It contains no serviceable parts.
- DO NOT expose the tester to extremes in temperature or high humidity.
OPERATING INSTRUCTIONS
SELECTING VOLTAGE TESTING MODE
NCVT-3P can detect voltage in two distinct modes, defined by the voltage
ranges to which the tester is sensitive. Mode 1 detects 70 to 1000V AC, Mode 2
detects 12 to 1000V AC. With the tester powered-ON, successive presses of the
NCV Power-ON button 1 will switch the tester between modes 1 and 2. The Power-
ON indicator LED’s 3 will indicate the currently active mode. The tester will
power in the mode that was most recently used.
OPERATING INSTRUCTIONS
CHECKING FOR THE PRESENCE OF AC VOLTAGE
- Press NCV Power On/Off button. After performing a self-test, a green light will illuminate the tip when no voltage is detected.
- Prior to use, test on a known live circuit to verify tester functionality.
- Place the tip of the tester 5 near the AC voltage. If voltage is present, the unit will emit audible beeps and the LEDs in tip 4 will illuminate:
Mode | Power-On LED Color | 12 to 70V AC | > 70 to 1000V AC |
---|
Mode 1
70 – 1000V Range| Red| No illumination, no sound| Red LED in tip 4
illuminated, continuous audible beep
Mode 2
12 – 1000V Range| Blue| Blue LED in tip 4 blinking, pulsing audible beep| Red
LED in tip 4 illuminated, continuous audible beep
NOTE: In Mode 2, the tester is more sensitive to high voltage sources and electrically noisy environments. It is recommended to set the tester to operate in Mode 1 when expected voltages are above 70V AC.
SILENT OPERATION
To activate silent operation, power-ON by pressing and holding the NCV Power-
ON button 1 for more than 2 seconds. Power-ON in this manner each time silent
operation is desired.
MAINTENANCE
BATTERY REPLACEMENT
When the battery is low, the unit will power on with a blinking red LED 3; at
this point, the NCVT-3P will disable the flashlight functionality to conserve
battery function for voltage detection.
- Unscrew the battery cap 9 and remove/recycle spent batteries.
- Install two new AAA batteries. Note proper polarity.
- Screw the battery cap tightly to ensure a tight seal with the O-Ring 8.
CLEANING
Be sure tester is turned off and wipe with a clean, dry lint-free cloth.
Do not use abrasive cleaners or solvents.
STORAGE
Remove the batteries when not in use for a prolonged period of time. Do not
expose to high temperatures or humidity. After a period of storage in extreme
conditions exceeding the limits mentioned in the General Specifications
section, allow the tester to return to normal operating conditions before
using.
DISPOSAL / RECYCLE
Do not place equipment and its accessories in the trash. Items must be properly disposed of in accordance with local regulations. Please see www.epa.gov/recycle for additional information.
CUSTOMER SERVICE
KLEIN TOOLS, INC.
450 Bond Street, Lincolnshire, IL 60069
1-800-553-4676
customerservice@kleintools.com
www.kleintools.com