KLEIN TOOLS VDV500-820E Tone & Probe PRO Wire Tracing Kit Instruction Manual
- June 3, 2024
- KLEIN TOOLS
Table of Contents
VDV500-820E Tone &
Probe PRO Wire Tracing Kit
Instruction Manual
GENERAL SPECIFICATIONS – VDV500-063 TONER-PRO
The Klein Tools VDV500-063 Toner-Pro is a professional-series tone generator for wire identification, wire tracing and wire pair identification on non- energised wires. It features several tone frequencies and a strong power output for tracing wires.
-
Operating Altitude: 6562′ (2000 m) maximum
-
Relative Humidity: 10% to 90%, non-condensing
-
Operating Temp: 14° to 122°F (-10° to 50°C)
-
Storage Temp: -4° to 140°F (-20° to 60°C)
-
Dimensions: 2.5″ x 5″ x 1″ (64 x 127 x 25 mm)
-
Weight: 7.4 oz (210 g) including batteries
-
Battery Type: 4 x 1.5V AAA Alkaline
-
Battery Life: Active: 120 hours
Standby/Storage: 3 years -
Auto Power-Off: After 60 minutes of inactivity
-
Tones: Constant: 800 Hz, 1000 Hz, 1500 Hz
Alternating: 800/1000 Hz, 1000/1500 Hz -
Tone Power: 8 dBm
-
Continuity Indication: Less than 10kΩ
-
Voltage Protection: Test Mode: 60 V
Tone Mode: 20 V through external 600 Ω
Specifications subject to change.
FEATURE DETAILS
T1 TEST MODE Indicator | T9 Power On/Off Button |
---|---|
T2 ‘NRM’ (Normal) Polarity Indicator | T10 TEST/TONE Button |
T3 ‘REV’ (Reverse) Polarity Indicator | T11 Battery Status Indicator |
T4 ‘CONT’ (Continuity) Indicator | T12 Lanyard Slot |
T5 TONE MODE Indicator | T13 RJ11 Test Plug |
T6 Tone Frequency Indicators | T14 ABN (Angled Bed-of-Nails) Test Clips |
T7 Tone Mode Down selector button | T15 Battery Cover |
T8 Tone Mode Up selector button | T16 Battery Cover Screw (No. 2 Phillips) |
GENERAL SPECIFICATIONS – VDV500-123 PROBE-PRO
The Klein Tools VDV500-123 Probe-Pro is a professional-series tone tracer, featuring an inductive probe with a speaker for amplification, and an LED light for use in dark spaces. It also features a headphone jack for use in extreme noise environments.
-
Operating Altitude: 6562’ (2000 m) maximum
-
Relative Humidity: 10% to 90%, non-condensing
-
Operating Temp: 14° to 122°F (-10° to 50°C)
-
Storage Temp: -4° to 140°F (-20° to 60°C)
-
Dimensions: 1.75″ x 8.88″ x 1.13″ (44 x 226 x 29 mm)
-
Weight: 5.7 oz (161.6 g) including batteries
-
Battery Type: 4 x 1.5V AAA Alkaline
-
Battery Life: Active: 25 hours
Standby/Storage: 3 years -
Auto Power-Off: After 10 minutes of inactivity
Specifications subject to change.
FEATURE DETAILS
P1 Replaceable Inductive Polymer Tip (VDV999-068) | P10 Lanyard Slot |
---|---|
P2 Worklight | P11 “-” (Negative) Terminal |
P3 Worklight On/Off Button | P12 “+” (Positive) Terminal |
P4 Signal Strength Indicator | P13 Terminal Release Buttons |
P5 Power On/Off Button | P14 Verification Indicator |
P6 Volume Increase Button | P15 Battery Cover |
P7 Volume Decrease Button | P16 Battery Cover Screw (No. 2 Phillips) |
P8 Battery Status Indicator | P17 3.5 mm Headphone Jack* |
P9 Speaker |
- CAUTION: Excessive volume can cause permanent hearing damage. Use as low a volume as possible.
WARNINGS
To ensure safe operations and service of the instruments, follow these instructions. Failure to observe these warnings can result in fire, electric shock, severe injury or death.
- The Toner-Pro and Probe-Pro are designed for use on extra-low voltage cabling systems (less than 60 volts) for testing when NOT energised.
- The maximum voltage across ABN Test Clips of the Toner-Pro is 60 volts in Test mode, and 20 volts in Continuity mode. Connecting the Probe-Pro to live mains AC power may damage it and pose a safety hazard for the user.
- DO NOT use instruments if they are wet, as it could pose a shock hazard.
- DO NOT use instruments if they are damaged in any way.
- Turn off instruments and disconnect all ABN Test Clips before attempting to replace batteries.
- The battery door must be in place and secure before you operate the instrument.
- DO NOT open the case, other than the battery compartment.
OPERATING INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE OPERATING AND RETAIN INSTRUCTIONS FOR FUTURE
REFERENCE CONTINUITY TEST
The Toner-Pro transmits frequencies on non-energised wires only. When the
Toner-Pro is turned on, a continuity test will be performed to determine if
the 2 wires to be traced are in close proximity to each other, without a
conductive path between them. The ‘CONT’ Indicator T4 will illuminate green to
indicate a pass. Attach the red and black ABN Test Clips T14 to the wires to
be tested. If the resistance of the circuit is less than 10kΩ, the ‘CONT’
Indicator T4 will illuminate red, indicating a short, and no toning can occur.
If the “CONT” Indicator is illuminated green, a tone can be generated and you
may proceed.
SELECTING TONE FREQUENCY
The Toner-Pro defaults to the 800 Hz frequency setting when powered on. Use
the Tone Mode Up T8 and Tone Mode Down T7 selector buttons to change the
frequency. The Tone Frequency Indicators T6 will display the frequency being
transmitted. If an alternating tone is selected, the two respective Tone
Frequency Indicators T6 will blink. Tones will cycle through the available
frequencies in a continuous loop when a selector button is pressed repeatedly.
TRACING PAIRED WIRES (FIG. 1)
- Connect the Toner-Pro’s red ABN Test Clip T14 to one of the wires of the pair to be traced. Connect the black ABN Test Clip T14 to the other wire to be traced.
- Turn Toner-Pro on by pressing the Power On/Off button T9 .
- Check the ‘CONT’ Indicator T4 . If it is illuminated green, you may proceed.
- Select the preferred tone setting using the Tone Mode Up T8 and/or Tone Mode Down T7 selector buttons.
- Turn the Probe-Pro on by pressing the Power On/Off button P5 .
- At the far end of the cable, spread the wires apart at least 2″ (51 mm), if possible.
- Use the Probe-Pro to scan the cable’s wire pairs. Move the Probe-Pro’s tip P1 slowly across the wires (FIG. 1).
The Probe-Pro’s volume will increase as it approaches the toned pair. When the Probe-Pro’s volume is high over the first wire, low in the middle (between) the two wires, and high over the second wire, you have located the pair of wires you are tracing. Use the Volume Increase P6 and Volume Decrease P7 buttons to adjust the volume.
OPERATING INSTRUCTIONS
VERIFYING TONED PAIRS (FIG. 2)
- To verify you have found the toned pair, connect the Toner-Pro’s ABN Test Clips T14 or RJ11 Test Plug T13 to one end of the cable and initiate a tone.
- On the other end of the cable, remove approximately 2 mm (3/32″) of the outer jacket of each of the wires believed to be the toned pair.
- Insert the wire connected to the red ABN Test Clip T14 to the “+” (Positive) Terminal P12 , and the wire curently in the black ABN Test Clip T14 to the “-” (Negative) Terminal P11 . To access the terminals, press their respective Terminal Release buttons P13 , insert the wire(s) and release (FIG. 2). The Verification Indicator P14 will
illuminate when the correct pair is inserted.
TRACING NON-PAIRED WIRES (FIG. 3)
- Connect the Toner-Pro’s red ABN Test Clip T14 to the wire to be traced.
- Connect the black ABN Test Clip T14 to another wire in the cable, but preferably not in the same pair (connect to the ground, if available). When tracing a shielded cable, connect the red ABN Test Clip to the outer shield, and the black ABN Test Clip to the center conductor or ground.
- Turn Toner-Pro on by pressing the Power On/Off button T9 .
- Check the ‘CONT’ Indicator T4 . If it is illuminated green, you may proceed.
- Turn the Probe-Pro on by pressing the Power On/Off button P5 .
- Select the preferred tone setting using the Tone Mode Up T8 or Tone Mode Down T7 selector buttons.
- At the far end of the cable, spread the wires at least 2″ (51 mm) apart, if possible.
- Use the Probe-Pro to scan the cable’s wire pairs. Move the Probe-Pro’s tip P1 slowly across the wires. The Probe-Pro’s volume will increase as it approaches the toned wire.
OPERATING INSTRUCTIONS
RJ11 / RJ12 / RJ45 TESTING
The Toner-Pro has an RJ11 Test Plug T13 that can be used in place of the ABN
clips to transmit the tone. The RJ11 plug works with RJ11, RJ12 or RJ45 jacks.
The red and black ABN contacts are replaced by the 2 center conductors of the
inserted plug, i.e. Pins 2 and 3 for RJ11, Pins 3 and 4 for RJ12, and Pins 4
and 5 for RJ45.
Use the Probe-Pro to locate the toned wires at the far end of the cable, as
described in the TRACING PAIRED WIRES section.
POLARITY AND VOLTAGE PRESENCE TESTING
The Toner-Pro may be used to test the polarity and type of voltage that is present.
- Press the Power On/Off button T9 on the Toner-Pro.
- Press the TEST/TONE Select button button T10 . The ‘TEST MODE’ indicator T1 will illuminate.
- Connect the ABN Test Clips T14 , or insert the RJ11 Test Plug T13 .
- Check the ‘CONT’ Indicator T4 . If it is illuminated green, you may proceed.
- The ‘NRM’ (Normal) Polarity Indicator T2 will illuminate if the red ABN Test Clip T14 is connected to the POTS (Plain Old Telephone Service) in the proper orientation. The ‘REV’ (Reverse) Polarity Indicator T3 will illuminate if the wires are reversed.
• The ‘NRM’ (Normal) Polarity Indicator T2 will illuminate when the black ABN Test Clip detects a higher voltage than the red ABN Test Clip.
• The ‘REV’ (Reverse) Polarity Indicator T3 will illuminate when the red ABN Test Clip detects a higher voltage than the black ABN Test Clip.
• The ‘NRM’ (Normal) Polarity Indicator and ‘REV’ (Reverse) Polarity Indicator will both illuminate when an AC voltage is present.
• When the RJ11 Test Plug is used, the ‘NRM’ (Normal) Polarity Indicator will illuminate on a correctly wired and powered POTS (Plain Old Telephone Service) phone jack.
NOTE : The POTS (Plain Old Telephone Service) colour code convention (black/positive, red/negative) is the opposite of the multimeter colour code convention (red/positive, black/negative).
USING THE PROBE’S WORKLIGHT
The Probe-Pro has a worklight P2 to aid in illuminating dark or low-light work
areas. Press the Worklight On/Off Button P3 to turn the light on and off.
MAINTENANCE
BATTERY REPLACEMENT
When the Low Battery Indicator P11 or P8 blinks, the batteries must be
replaced.
- Turn off instrument(s) before attempting to replace the batteries.
- Loosen screw T16 , P16 on the battery cover T15 , P15 .
- Remove and properly dispose of four 1.5V AAA batteries.
- Install new batteries (note the proper polarity).
- Replace battery cover and fasten securely with the screw.
**To avoid risk of electric shock, do not operate while battery door is removed.**
PROBE-PRO TIP REPLACEMENT (KLEIN CAT. NO. VDV999-068)
The tip P1 of the Probe-Pro is replaceable if damaged. To remove and replace
tip:
- Turn tip 1/4 turn and pull gently to remove.
- Insert new tip with key in the proper orientation and push gently.
- Rotate 1/4 turn to lock into place.
CLEANING
Be sure instrument is turned off and wipe with a clean, dry lint-free cloth. Do not use abrasive cleaners or solvents.
STORAGE
Remove the batteries when instrument is not in use for a prolonged period of time. Do not expose to high temperatures or humidity. After a period of storage in extreme conditions exceeding the limits mentioned in the GENERAL SPECIFICATIONS section, allow the equipment to return to normal operating conditions before using.
WARRANTY
DISPOSAL RECYCLE
Do not place equipment and its accessories in the trash. Items must be properly disposed of in accordance with local regulations. Prior to disposal of this product, please contact Klein Tools for proper disposal options.
NOTES………..
CUSTOMER SERVICE
KLEIN TOOLS, INC.
450 Bond Street
Lincolnshire, IL 60069
800-553-4676
1390411 Rev 08/21 B
customerservice@kleintools.com
www.kleintools.com
References
- Bundesministerium für Land- und Forstwirtschaft, Regionen und Wasserwirtschaft (BML)
- Netzwerk-Distributor | NetPeppers GmbH
- stiftung-ear.de
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>