LUMASCAPE LS6540 PowerSync PS4 Data Injector Instruction Manual
- June 4, 2024
- LUMASCAPE
Table of Contents
- LUMASCAPE LS6540 PowerSync PS4 Data Injector
- READ ALL SAFETY INSTRUCTIONS FIRST
- Mode Switch and Indicator Light Descriptions
- Indicator Light
- Wiring for DMX Controllers (International)
- Wiring for DMX Controllers (North America)
- Wiring for 0-10 V Sinking Dimmers (International)
- Wiring for 0-10 V Sinking Dimmers (North America)
- Wiring for 0-10 V Soucing Dimmers (International)
- Wiring for 0-10 V Sourcing Dimmers (North America)
- Testing Functions
- Network Topology – PowerSync Dimmable
- Network Installations
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
LUMASCAPE LS6540 PowerSync PS4 Data Injector
DANGER
ISOLATE DEVICE FROM POWER
Failure to isolate power supply before installation or maintenance may result
in fire, serious injury, electric shock, death and may damage the luminaire.
Product Warranty is void if product is not installed as per installation instructions and in compliance with the local electrical code.
READ ALL SAFETY INSTRUCTIONS FIRST
- Follow instructions carefully; failure to do so will void warranty.
- Ensure installation complies with local laws and applicable standards
- Only use Lumascape power supply, control equipment and leader cables.
- Ensure mains input power is surge protected.
- Never make connections whilst power is connected.
- Do not make modifications or alter product.
- Connectors are to be kept clean and dry at all times.
- Once installed, all connectors are to be mated and a PowerSyncTM terminator is required on the last fitting of run.
Mode Switch and Indicator Light Descriptions
Indicator Light
Wiring for DMX Controllers (International)
10 Position Mode Switch
- DMX/RDM
- DMX/RDM + Relay
- Test All Channels Off
- Test All Channels On
- Test 4 Color Cycle
Note
- This function list is ONLY for Generation 2 PowerSync Injectors.
- For non-generation 2 devices, visit Lumascape website for applicable instructions.
- Generation 2 is marked on the label inside the PowerSync Injector.
Wiring for DMX Controllers (North America)
Wiring for 0-10 V Sinking Dimmers (International)
10 Position Mode Switch
- Test All Channels Off
- Test All Channels On
- 0-10 V Sinking
NOTE:
- This function list is ONLY for Generation 2 PowerSync Injectors.
- For non-generation 2 devices, visit Lumascape website for applicable instructions.
- Generation 2 is marked on the label inside the PowerSync Injector.
Wiring for 0-10 V Sinking Dimmers (North America)
Wiring for 0-10 V Soucing Dimmers (International)
Wiring for 0-10 V Sourcing Dimmers (North America)
Testing Functions
To assist with installation, the LS6540 provides three (3) test modes for
PowerSync™ luminaires. These require only connected luminaires and power, and
no connected input signal.
If an input signal is connected, the LS6540 will not respond to this signal in
any of the modes below.
NOTE: These test signals apply to the relevant unit’s PowerSync™ output
only –– it will not be passed through on the DMX / RDM connectors if multiple
LS6540 units are connected.
10 Position Mode Switch
Network Topology – PowerSync Dimmable
Up to 45 luminaires per run under the following conditions:
-
Max total cable run length 150m (492’) in up to two trunk cables
-
For run lengths in excess of 30m (100’), the data wire gauge cannot exceed 12-14 AWG (2.5mm2)
-
For run lengths up to 30m (100’), the data wire gauge is not governed
-
Refer to ‘Maximum Circuit Load’ table for circuit limitations
-
Always observe local electrical codes for branch circuit current limitations
-
Terminator
Use PowerSync™ terminator, supplied with leader cable to terminate last luminaire in chain. -
aximum Current
≤16.0A through LS6540 Data Injector. -
Connection Type
Circuits can be configured as either connectorised or hardwired. For details consult installation instructions and comply with local electrical codes. -
PLEASE CHECK LUMINAIRE DATASHEETS FOR CIRCUIT LOADING AND ELECTRICAL LIMITATIONS.
Network Installations
International
North America
Please Note: The above diagrams are intended to show electrical pathways between luminaires and ancillary device. These diagrams are not intended to show type or colour of cord / wire, luminaire input voltage rating, wire gauge or approved use of the cord / wire supplied with luminaires.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>