TOOLOTS KC-9558 Kunchy Wheel Balancer Instruction Manual
- June 12, 2024
- TOOLOTS
Table of Contents
TOOLOTS KC-9558 Kunchy Wheel Balancer
Warning
- This manual is a necessary part of the product. Please read carefully.
- Keep the manual for later use when maintaining the machine.
- This machine can only be used for the designated purposes. Never use it for any other purpose.
- The manufacturer is not responsible for the damage incurred by improper use or use other than the intended purpose.
Precaution
- The equipment can only be operated by qualified personnel with special training. Modification to any components or parts, or use the machine for other purpose without either obtaining the agreement from the producer, or observing the requirement of the instructions may lead to direct or indirect damage to the equipment.
- The equipment should be installed on the stable ground, not wooden pallet, otherwise not accurate.
- Keep the back panel 0.6M away from the wall for good ventilation. Enough room should be left on both sides for convenient operation.
- Do not put the equipment a place with high temperature or moisture, or near the heating system, water tap, air-humidifier or chimney.
- Avoid lots of dust, ammonia, alcohol, thinner or spraying binder.
- People who are no operating the machines should be kept away when it is used.
- Use appropriate equipment and tools, protective and safety equipment, including eyeglasses, earplugs and working boots.
- Pay special attention to the marks on the machine.
- Do not touch or approach the moving parts by hand during operating.
Do not remove the safety device or keep it from working properly.
General
Technical data
- Power Supply Voltage 110 V, 60 Hz, 1 Ph
- Motor 0.34 HP ( 0.25 kW )
- Working Temperature 23 °F to 122 °F ( -5 °C to 50 °C )
- Cycle Time 6 to 9 seconds
- Data Entry Keypad
- Balancing Modes Dynamic / Static / Alloy
- Certification CE Approved
- Rim Diameter Capacity 10″ – 24″ ( 254 mm – 610 mm )
- Rim Width Capacity1 1/2″ – 16″ ( 38 mm – 406 mm )
- Max. Wheel Diameter 39 3/8″ ( 1000 mm )
- Max. Wheel Weight 154.32 lbs ( 70 kg )
- Shaft Size 36mm
- Max. Shaft Weight 176.37 lbs ( 80 kg )
- Balancing Speed 180 RPM
- Accuracy 0.035 ounces ( 1 gram )
- Display Standard or Metric
- Self Calibration Yes
- Power Cord Length 78 47/64″ ( 2000mm )
- Noise Level < 70 dB
- Product Dimensions L 44.09″ x W 25.98″ x H 39.76″ ( 1120 mm x 660 mm x 1010 mm )
- Product Weight176.37 lbs ( 80 kg )
Features
- ALU balancing mode may choose 9 o’clock or 12 o’clock position to add weight
- Statistic and dynamic balancing, ALU-programs for alloy rims or special shaped
- Self diagnoses, easy to find the problem
- Apply to steel and aluminum alloy rim
Working environment
- Temperature:5~50℃
- Height:≤4000m
Machine assembly
- Unpack
- Unpack the carton, check if missing any spare parts.
No. | Item | Qty |
---|---|---|
1 | Width gauge | 1 |
2
| Conic No.1| 1
Conic No.2| 1
Conic No.3| 1
Conic No.4| 1
3| Quick release nut| 1
---|---|---
4| Thread hub| 1
5| Bowl for a quick nut| 1
6| Pad for bowl| 1
7| Balancing hammer| 1
8| 100g weight| 1
9| Allen wrench| 1
Install
- The equipment should be installed on the stable ground, not wooden pallet, otherwise not accurate.
- Keep the back panel 0.6M away from the wall for good ventilation. Enough room should be left on both sides for convenient operation.
- Fix balancer to floor with screws on the bottom.
- Install adaptor
- The wheel balancer is supplied complete with cone type adaptor for fastening wheel with central bore. (see below picture)
Install wheel
- Clean wheel, take off counterweights, check pressure of wheel.
- Choose the way of installation according to the type of wheel.
Attention: May add a wheel, and hold the wheel to help install the thread hub. When installing or taking off wheel, do not let wheel move on the shaft, to avoid scratching shaft.
Display plate
- inside unbalance value digital display
- inside unbalance position display
- outside unbalance value digital display
- outside unbalance position display
- displays showing type of correction chosen.
Eight balancing modes
Key board (H)
Indication and use of wheel balancer
DYN (Standard/Default) mode
Clean wheel, take off counterweights, check pressure of wheel.Choose the way of installation according to the type of wheel.
Attention:May add a wheel, and hold the wheel to help install the thread hub. When installing or taking off wheel, do not let wheel move on the shaft, to avoid scratching shaft.
Turn on machine
- Input a b d value
- Turn on machine, choose right way to install wheel according to the type of wheel. Set “a” “b” “d” values:
- set “a” value : move the gauge to measuring position as illustrated as Fig.1, hold the gauge still in position for approx. 4 seconds, successful memorization is given, then return the gauge to position 0.(The value measured in automatic mode appear on the display). Or press and to set manually.
- set “b” value:set nominal diameter “b” marked on the wheel or use the width gauge to measure the value of ”b” as Fig.2, then press and .
- set “d” value:this value measured in automatic mode same time as “a” value setting, or press and to set manually.
Put down the guard and press to perform a measuring spin
- In a few seconds the wheel is brought to operating speed and begin measuring unbalance, the unbalance values remain on instruments 1 and 3 when the wheel stopped. The press may check the real unbalance value under threshold.
- Anticlockwise moving wheel slowly, until the right LED lit up full, clip weight on 12 o’clock position (Fig.3)
- Anticlockwise moving wheel slowly, until the left LED lit up full, clip weight on 12 o’clock position (Fig.4)
- After finishing cliping the counterweights, put down the guard or press , to perform balancing spin again, if comes out 00 00,means balancing succeed. (Fig.5)
ALU-1 mode (ALU-1, ALU2 same operation, only the position to add weights different)
- Set “a” “d” “b” values
- Press until ALU1 indicator lit up
- Put down the guard and press to perform a measuring spin.
- In a few seconds the wheel is brought to operating speed and begin measuring unbalance, the unbalance values remain on instruments 1 and 3 when the wheel stopped. The press may check the real unbalance value under threshold.
- Anticlockwise moving wheel slowly, the displays with right LED’s lit up full indicate the correct angular position where to mount the counterweights, 12 o’clock position (9H=Off) or 9 o’clock (9H=On) position outside, as Fig.6, add the counterweight.
- Anticlockwise moving wheel slowly, the displays with left LED’s lit up full indicate the correct angular position where to mount the counterweights, 12 o’clock position (9H=Off) or 9 o’clock (9H=On) position inside, as Fig.7, add the counterweight.
- After finishing mounting the counterweights, put down the guard and press , to perform balancing spin again, if comes out 00 00, means balancing succeeds. (Fig.8)
ALU-S mode
This mode is used for special rims, if ALU1/ALU2 can not be used, you should choose ALUS mode. Input aI, aE, d value
- Set “aI”: pull the gauge out and let the gauge head touch the position of FI for 4 seconds, may press and to change
- Set “aE”: pull gauge outlet the gauge head touch the position of FE for 4 seconds, may press and . to change
- Set “d”: read from rim, press , and input.
Put down the guard and press to perform a measuring spin.
- clock position to add weight
- Set SLC as OFF according to 8.1
- Anticlockwise moving wheel slowly, until the right LED lit up full, add weight on 12 o’clock position (Fig.10)
- Anticlockwise moving wheel slowly, until the left LED lit up full, add weight on 12 o’clock position (Fig.11)
- After finishing mounting the counterweights, put down the guard and press ,to perform balancing spin again, if comes out 00 00,means balancing succeed. (Fig.12)
Use gauge head to add weight
Set SLC as ON according to 8.1
-
Anticlockwise moving wheel slowly, until the right LED lit up full (Fig.14)
-
Take off proper counterweight to be hold by the gauge head as Fig. 16
-
Pull out gauge until there is a square comes in the middle window (Fig. 17)
-
Release the counterweight and let it stick on rim (Fig. 18)
-
Anticlockwise moving wheel slowly, until the left LED lit up full (Fig.19)
-
Take off proper counterweight to be hold by the gauge head as Fig. 16
-
Pull out gauge until there is a square comes in the middle window (Fig. 20)
-
Release the counterweight and let it stick on rim (Fig. 21)
- Then turn down safe guard and press to start spin, comes Fig. 22 means the wheel is balanced.
ALUS split function
Note: Only ALU-S mode can use this function. And Operator must be experienced.
Self-calibration of wheel balancer
- Self-calibration of wheel balancer
- Turn on balancer, install a medium size wheel (14″-18″)which can use clip-on weight, set “a b d” value, then
- Do the self-calibration whenever you think the balancer is not accurate. The 100g weight must be accurate.
Rim distance gauge calibration
Rim diameter gauge calibration
Errors
Various abnormal conditions can arise during machined operation by the microprocessor, if comes the errors, must stop operation, find the reason and the solution according, if the error persists, consult the supplier.
Self- diagnoses
Press and hold, then press goest to self diagnoses, press to next , press to escape.
Setting machine
- Machine setting
- Press and hold, then press goes to set machine, press and to change,press to next.
Safe guard setting
- Press and hold, then press to set safe guard.
Unit of weight setting
- Press + to set safe guard.
OPT function
Note: When unbalance value is too much, choose OPT, and operator must be
experienced.
- Install wheel, input a b d value.