HYPERLITE Hive Series LED Work Light Instructions
- June 12, 2024
- HYPERLITE
Table of Contents
RELIABLE SOLID BRIGHT
Hive Series LED Work Light
FEATURES
– 4KV Surge Protection, lamp can bear sudden high voltage.
– 50,000hours life span with 5 years warranty.
– Painted metal guard for impact protection.
– 10ft 16AWG cord with plug suitable to huge construction area.
SPECIFICATIONS
Performance Data | BWRL-60W-B | WRL-100W-B | BWRL-120W-B |
---|---|---|---|
General | Lumens | 7500 Im | 12500Im |
Efficacy | 125 Im/W | ||
CCT | 5000K | ||
CRI | >80 | ||
Life span | >50,000 hours | ||
Electrical | Power | 60W | 100W |
Input voltage | AC 120V | ||
Surge protection | 4KV surge protector for optional | ||
Power factor | >0.9 | ||
Options | Operating temperature | -40°F to 113°F | |
Listings | UL, cUL | ||
Warranty | 5 Years |
PACKAGING INFORMATION
Model| Wattage| Qty| Net Weight| Gross Weight| CTN
Size
---|---|---|---|---|---
BWRL-60W-B| 60w| 1| 42±1lbs| 5.0±1lbs| 7.7″7.7″12.9″
BWRL-100W-B| 100W| 1| 5.0±1lbs| 5.8±1lbs| 7.7″7.7″13.5″
BWRL-120W-B| 120W| 1| 5.3±1lbs| 6.2±1lbs| 7.7″7.7″15.7″
INSTALLATION
– Place the work light up to the hanging hardware, push the gate of the
carabiner clip against the hanging hardware until it opens (Pic 1).
– Captures the hardware (Pie 2) The installation is now completed.
CONNECTION
Hidden & built-in connector design. Customer can choose to connect several
work lights in series or not.
Suitable to damp location. – Linking Additional Units
Install each additional unit as in STEP 1. When adding units, turn cage light
off prior to adding the additional units.
Max 7x120W can be linked on one string of lights and must NOT EXCEED 10A. Open
the outlet access door in order to gain access to the grounded outlet (Pic3).
Plug each additional light into the preceding unit (Pic4). Lock each plug in
place by closing the locking buckle onto the plug (Pic. 5-6). Repeat as
necessary.
Wattage | UL Current@120V | Link-able Qtys |
---|---|---|
120W | 1.296 | 7PCS |
100W | 1.08 | 9PCS |
60W | 0.65 | 15PCS |
LED Work Light
(Hive Series)
UL CERTIFICATION
Certificate Number: E503681
Report Reference: E503681
Issue Date: 2018-DECEMBER-31
Additional Information:
See the UL Online Certifications Directory at
www.ul.com/database for additional information.
A Only those products bearing the UL Certification Mark should be considered
as being covered by UL’s Certification and Follow-Up Service.
A Look for the UL Certification Mark on the product. ATTENTION
BEFORE YOU INSTALL
Read these instructions completely and carefully.
WARNING
RISK OF ELECTRIC SHOCK
- Turn power off before inspection, installation or removal.
- Properly ground electrical enclosure
- Follow all NEC and local codes.
- Use only UL or IEC approved wire for input/output connections.
Save These Instructions
Use only in the manner intended by the manufacturer If you have any questions,
contact the manufacturer.
Prepare Electrical Wiring
Electrical Requirements
The LED driver must be supplied with 120VAC, 60Hz per product label and
connected to an individual properly grounded branch circuit, protected by a 15
or 20 ampere circuit breaker.
Grounding Instructions
The grounding and bonding of the overall system shall be done in accordance
with National Electric Code (NEC) Article 600 and local codes.
Note: This equipment has been tested and found to comply with the limits
for a Class A digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense. Please
check that the plug is in good condition.
Install the lamp and plug it into the socket.
Then you can test the light fixture.
APPLICATION
Task lighting, commercial lighting, work areas etc.
FOOTCANDLE LIGHT GUIDE
Footcandles are the most common unit of measure used by lighting professionals to calculate light levels in businesses and outdoor spaces. A footcandle is defined the ii luminance on a one square foot surface from a uniform source of light. The Illuminating Engineering Society (IES) recommends the following footcandle levels to ensure adequate illumination and safety for occupants. Below is a guideline for common areas to assist in achieving appropriate light levels with the greatest energy-efficiency.
Buildinc Area &Task| Average
Maintained
Footcandles
(Horizontal) (FC)| Range of
Maintained
Footcandles
(Horizontal) (FC)| Average
Maintained
Footcandles
(Vertical) (FC)| Range of
Maintained
Footcandles
(Vertical) (FC)| Comments
---|---|---|---|---|---
WAREHOUSING & STORAGE
Bulky Items—Large Labels| 10| | 5|
---|---|---|---|---
Small Items—Small Labels| 30| | 15|
Cold Storage| 30-40| 10-30| 10| 5-15
Open Warehouse| 30-40| 10-30| |
Warehouse w/Aisles| 30-40| 10-30| 10| 5-15
COMMERCIAL OFFICE
Open Office | 40 | 30-50 | @30″ Above Finished Floor (AFF) |
---|---|---|---|
Private Office | 40 | 30-50 | @30″ AFF |
Conference Room | 30 | Matte surface reflectance for the table 40% recommended | |
Restroom | 18 | 75-30 | |
Lunch & Break Room | 15 | 5-20 |
EDUCATIONAL (SCHOOLS)
Classroom | 40 | 30-50 | @30″ AFF | ||
---|---|---|---|---|---|
Gymnasium | |||||
Class I (Pro or Div. 1 College) | 125 | 30 | |||
Class II (Div. 2 or 3 College) | 80 | 20 | |||
Class III (High School) | 50 | 150 | |||
Class IV (Elementary) | 30 | 100 | |||
Auditorium | 75 | 3-10 | 5 | 2 5-10 | |
Corridor | 25 | 10-40 |
This guide is a collaborative effort of Energy Trust of Oregon and the Lighting Design Lab, Seattle, Washington.
Building Area &Task| Average
Maintained
Footcandles
(Horizontal) (FC)| Range of
Maintained
Footcandles
(Horizontal) (FC)| Average
Maintained
Footcandles
(Vertical) (FC)| Range of
Maintained
Footcandles
(Vertical) (FC)| Comments
---|---|---|---|---|---
INDUSTRIAL/MANUFACTURING
Assembly| | | |
---|---|---|---|---
Simple (Large Item)| 30| | 15| 15-60
Difficult (fine)| 100| 10-30| 10| 50-200
Component Manufacturing| | | |
Large| 30| 10-30| 30| 15-60
Medium| 70-80| 25-100| 50| 25-100
EXTERIOR
Parking (Covered) | 5 | 1FC min,10:1 Max to Min Uniformity | |||
---|---|---|---|---|---|
Parking (Open) (Medium Activity) | |||||
Lighting Zone 3 (Urban) | 1.5 | 75-3 | 0.8 | 0.4-1.6 | |
Lighting Zone 2 (suburban) | 1 | 0.5-2 | 0.6 | 0.3-1.2 | |
Gas Station Canopy | 12.5 | 10-15 | |||
Safety (Building Exterior) | 1 | 0.5-2 | If security is an issue-raise |
average level to 3
RETAIL
General Retail (Ambient)| | 50| | |
---|---|---|---|---|---
Department Store| 40| 20 – 80| 15| 7.5-30|
Perimeter| | | 75| 35-150|
Accent Lighting (Displays)| | | | | 3-10 times greater than ambient light
levels
AUTOMOTIVE
Showroom | 70-80 | 25-100 | 10 | 7.5-30 |
---|---|---|---|---|
Service Area | 50 | 25-10 | 30 | 15-30 |
Sales Lot (Exterior) | ||||
Lighting Zone 3 (Urban) | 20 | 10-40 | 20 | 10-40 |
Lighting Zone 2 (Suburban) | 15 | 7.5-30 | 15 | 7.5-30 |
GROCERY
Circulation | 20 | 10-40 | 7.5 | 3.5-15 |
---|---|---|---|---|
General Retail | 70-80 | 25-100 | 20 | 10-40 |
Perimeter | 50 | 25-100 |
BANKING
ATM | 20 | 10-40 | 15 | Vertical at face of ATM |
---|
NOTES:
-
This guide is based on information gathered from the IES ‘The Lighting Handbook’ 10th Edition.
It is highly recommended that all lighting professionals refer to the full I ES guide when specifying lighting projects -
At least half of users are in the 25-65 age range.
-
Horizontal-horizontal plane that average maintained foot-candles are measured.
-
Vertical-vertical plane the average maintained foot-candles are measured
-
It is the responsibility of the to determine and provide appropriate lighting levels for each space.
LED High Bay Light LED Flood Light
LED Grow Light Area Light & Canopy Garage Light
LED Vapor Tight Light LED Wall Pack Light
Temporary Work Light More products..
www.hi-hyperlite.com
Web: www.hi-typerlite.com
Email: service01@hi-hyperlite.com
Tel: +1(855) 688 7879
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>