ENERNOVA ETA Pro 1050Wh 1200W Portable Power Station User Manual

June 12, 2024
ENERNOVA

ENERNOVA ETA Pro 1050Wh 1200W Portable Power Station ETA Pro 1050Wh 1200W Portable Power Station
User Manual

Charge first- Before using, plugitinto the power outlet until it is fully charged.

Safety Instructions

1.1 Disposal Guide

  1. The product contains high voltage AC output, please do not put your hand or handheld metal conductor into the AC outlet.
  2. Do not disassemble the product if you are not professionals because internal battery and circuit of the product have dangerous high energy which is able to cause electric shock, short circuit and other dangerous things to happen.
  3. Do not put the product in high temperature environment (more than 50 degrees Celsius) or near the fire to avoid the product from explosion or catching fire.
  4. The product is not a toy. Keep the product out of the reach of chil- dren.
  5. Do not use it in a damp environment.
  6. Please do not knock or hit the product.
  7. Itis strictly forbidden to disassemble the product.
  8. Itis strictly forbidden to use products with obvious damage.
  9. All parts of the product are environmental friendly and recyclable, please recycle according to local regulations.

1.2 Usage

  1. Please select the solar panel in accordance with the electrical para- meters specified by the manufacturer. It is forbidden to charge with solar panels whose voltage is higher than 50V.
  2. Please charge the battery within the temperature range of 0~45°C. Charging at too low temperature will shorten the cycle life of the battery.
  3. For long term storage (more than 3 months), it should be stored in a low humidity environment without corrosive gas at -10~50°C in a se- mi-electric state.
  4. If the power station is stored for more than 6 months, please charge and discharge the product 1-2 times every three months to extend the life of the battery.
  5. In order to preserve the power of the product, please turn off the product in time after using so as to avoid running out of the battery power (the device will have no-load loss as long as it is turned on).
  6. When the product runs out of power, please charge it in time.
  7. If the product emits abnormalities such as odor and overheat during charging or storage, please stop charging immediately and place it in an open place for observation from a distance to confirm safety, and contact the manufacturer or distributor after it.
  8. The product has a wireless charging function. If the wireless charging switch is turned on, the wireless charging function will be turned on. Please note that the charging part on the back of the phone cannot be made of metal (such as a bracelet). If there is metal, it will cause heat. Do not put metal objects or radio-sensitive items on the top of the power supply. Otherwise, it may cause abnormal heat or even damage!
  9. This product is a power station, please select the corresponding model according to the electrical equipment. The use of this product with excessive power and load is prohibited.
  10. When the short-circuit protection occurs after the product is con- nected to the device, if it is still protected after restarting, please do not restart it again. You should find the reason for the protection of the connected device, and then continue to use the  roduct after troubleshooting.
  11. This product is factory set according to the voltage standards of di- fferent countries. Please consult the dealer or check the product instru- ction manual before purchase and use.
  12. The mesh holes on both sides of the power supply are heat dissipa- tion holes, which are strictly prohibited to be blocked and a certain space should be reserved to ensure the heat dissipation effect.

Package List

Please kindly check all accessories are complete
If any charger cables missing, please feel free to contact us at: support@enernovatech.com

ENERNOVA ETA Pro 1050Wh 1200W Portable Power Station -
List

Technical Specification

General Specs

Net Weight 35.21lbs(16kg)
Dimensions 14.4in x 9.251n x 10.5in (36.6cm x 23.5cm x 26.6cm)
Capacity Outputs 1050Wh
AC Output (x3) Pure Sine Wave 1200W (Surge 2400W) tota1,100-120 Vac,

200-240Vac(50/60Hz)
USB-A Output (x21| 5V – 2.4A. 15W Max (per oort)
OC 3.0 Outout (x1)| 5V- 3A. 9V- 2A. 12V – 1.5A. 18W Max
USB-C Output (x3)| 5V – 3.25A.9V – 3.25A.12V – 3.25A,15V – 3.25A.
20V – 3.25A, 65W Max’1;5V – 2.4A, 12W Max (per port)’2
Car Power Output (x1)| 12.W – 8.3A, 100W Max
Wireless Output (xl)| 15W
Input|
AC Charger Input| i Ia.: – ii:‘,100V – 10A,220V – 4.54A, 1000W Max
Solar Charge Input| 11-50V- 12A, 400W Max
Car Charge Input| 12V-24V – 10A, 100W
Battery|
Cell Chemistry| Lithium Iron Phosphate
Operating Temperature| Ot-45t(327-1137)
Recharging Temperature| 0°C-45`C (32°F-113°F)
Warranty Life| 5 Years
Cycle Life| 3000 times to 80%+ capacity

*Please note:
The following information has been obtained under supervised test conditions.

Getting Started

3.1 Input & Output Ports

ENERNOVA ETA Pro 1050Wh 1200W Portable Power Station - Out put
ports

3.2LCD Screen

ENERNOVA ETA Pro 1050Wh 1200W Portable Power Station - LCD
Screen

3.3 Battery Cells
3.3.1 Power Reserve:
The storage capacity of the power supply is the rated value. The rated power storage of the power Station is shown in the parameter label in the power station manual, which is usually marked directly Wh, and the rated voltage (V) and rated capacity (mAh) are  also marked, and the power storage (Wh) = rated voltage rated capacity (mAh) / 1000.
3.3.2 The Actual Power Discharged From the Power Station:
The actual power discharged by the power station is related to the fol- lowing parameters:

  1. Ambient Temperature
    The ambient temperature has a great influence on the power dischar- ged from the battery, for example, the range of electric vehicles will be shortened when they are used in cold areas. Generally speaking, with the rated 25°C(77°F) as the base, for every 10°C(50°F) decrease above 0 °C(32°F), the power discharged will be reduced by 10-15%. For every 10 °C(50°F) lower than 0°C, the power discharged will be reduced by 30%.

  2. Efficiency
    During the discharge process, the battery voltage needs to be transfor- med, which inevitably brings energy loss, especially the inverter (AC output) part, which is influenced by the ambient temperature and the power level of the equipment running, and the loss varies from 5-15%. Therefore, the measured power released from the output side under full load is only 85%-95% of the rated capacity.

3.3.3 Power Station with Load Time:
Operating time = 1050Wh * 0.85 / your device’s operating power. (15% loss).
The duration of our devices is based on laboratory data and may vary for specific device use.
3.4 The Output Power of the Power Station
3.4.1 Definition of Rated Power:
The rated output power of the power station refers to the rated output power of the inverter (AC output) part, and the rest of the power is ge- nerally not marked because the power is relatively small compared to the inverter (AC output). Power station can be AC part of the full power and other ports full power output at the same time.
3.4.2 Notes on the Power of Connected Devices:
For such devices with very high starting current (3-5 times the rated power) and long starting time (about 10S), for example: hair curlers, laser printers, with motors and non-inverter type loads (air conditio- ners, washing machines, etc.). The display of the output will exceed a lot, this is normal. Please pay extra attention to the fact that the rated power of the power station should be 3-5 times greater than the rated power of these appliances.
3.4.3 Display of Output:
Some appliances may be marked with their rated power, which itself also needs to calculate the actual operating efficiency or slightly diffe- rent according to the output voltage, so if the power displayed by the power station itself is not much different from the rated power of the device itself (e.g. 20%), it is generally a normal phenomenon. If it exce- eds more, you need to verify the power of the equipment or need to confirm the existence of power or load failure.
3.5 Alarm Function
When the power station triggers the protection mechanism, it will au- tomatically cut off all outputs and enter the alarm reminder, while the screen icon will flash synchronously and continue to alarm for 60 se- conds until the user manually turns off the power.
3.6 EPS and Bypass Function
When your ETA Pro is plugged into the wall, anything plugged into it gets power from the grid, not its battery. If power from the grid stops, ETA Pro automatically switches to its battery supply mode within 30 milliseconds.
3.7 Auto Power Off
3.7.1 When all outputs of DC/AC/USB/Wireless charger are off, the display will enter hibernation mode after 50 seconds and will shut down automatically after 1 minute.
3.7.2 If the AC/DC/USB/Wireless charging ports are all open or one of them is open, the display will not automatically shut down.
3.8Fan
When the temperature of the power station exceeds 45°C, the fan will start to run and accelerate as the temperature rises to better help the power station dissipate heat. If the product is still hot inside after the load is removed, the fan will continue to run and dissipate heat to extend the life of the power sta- tion. Typically, the fan will stop spinning after about 10 minutes of ope- ration (depending on the load power and site temperature).
3.9 Wireless Charging
The wireless charging logo is on the top of the power station (the circle at the top is the center of wireless charging). Please activate the wire- less charging mode before use.

4. Recharging

The product has a charging protection function, once the productis fully charged, it will automatically stop charging. It is recommended to disconnect the charging connection in time after the product shows that it is fully charged.
4.1 Solar Charging
The XT60 charging port on the ETA Pro can be connected to a solar panel for charging (requires the use of an XT60 adapter cable in the solar panel).
The product is equipped with an internal MPPT system. When connec- ted to the solar panel, the product will automatically start charging and the battery icon will scroll while the screen will show the charging power.
The power of the solar panel is greatly affected by light, so the input power may fluctuate, which is normal.

ENERNOVA ETA Pro 1050Wh 1200W Portable Power Station - LCD Screen
1

4.2 AC Charging
Plug the AC input port of the charging cable into the AC power supply.
Plug the output port of the charging cable into the mains charging port on the side of the power supply and the battery icon starts to scroll while the charging power is displayed.

ENERNOVA ETA Pro 1050Wh 1200W Portable Power Station -
Charging

4.3 Car Charging
Plug the DC input of the Car charging cable into the Car cigarette ligh- ter. Plug the DC output of the car charging cable into the XT60 port of the portable power station and the battery icon will scroll while the charging power is displayed.

ENERNOVA ETA Pro 1050Wh 1200W Portable Power Station - Charging
1

Troubleshooting

5.1 Charging Failure
5.1.1 The charging cable is not plugged into place. Please insert the input and output of the charging cable into place.
5.1.2 The ambient temperature is too high. It is dangerous to use the lithium battery at temperatures above the specified temperature, so if the ambient temperature is low or high, the product’s internal tempe- rature protection will stop charging and discharging. In this case, please wait for the product temperature to recover before using it.
5.1.3 Please make sure that the voltage version of the purchased power station meets your local utility power standard (110V in the US, 100V in Japan, 230V in Europe).
5.2 Automatic Shutdown When Loading
5.2.1 The power of the rear stage load exceeds the specified value (after the load is connected, the power is turned on and the alarm icon on the display will light up after the output is automatically cut off). Please note that some loads have a high starting current although the nominal power is small, which will also cause the product to enter the overload protection state.
5.2.2 Short-circuit fault exists in the rear load: Confirming this fault requires a professional to measure it with special tools (such as using a multimeter to measure the resistance of the rear device). Overload or short- circuit fault can be confirmed with a normal low-power load. If there is no problem with a slightly lower-power load, it is usually a rear load overload or short-circuit fault.
5.2.3 The display protection mark lights up during operation, no output: the internal temperature of the inverter may be too high, the power station stops output, normal ambient temperature, normal load generally does not appear this situation, if it appears, please check ac- cording to the following recommendations. First, whether the ambient temperature is too high resulting in the internal temperature rise of the power station exceeds the specified value; second, both sides of the power station have heat dissipation holes, you need to leave at least 20cm of space for air circulation heat dissipation, pay attention not to place some light paper, plastic film, cloth and other soft materials, be- cause the fan will form suction when turning, these materials are ad- sorbed will greatly affect the power station heat dissipation resulting in internal protection. After eliminating the above abnormalities, the power station can be used again after cooling for a period of time.
5.2.4 Product failure. If the above abnormalities are excluded and the product still does not work properly, the power station itself may be malfunctioning and needs to be repaired.
5.3 Automatic Shutdown After Outputting
In order to save power consumption and avoid no power available at the time of need, the device will rest at 50 seconds when no output port switch is turned on, and then automatically shut down after 60 se- conds. If you need to use it at this time, you need to restart the power station.
5.4 Unable to Power On
5.4.1 Ambient temperature exceeds the specified temperature power internal protection. Lithium-ion batteries over the specified tempera- ture use is very easy to dangerous, so if the ambient temperature is very low or very high, the product’s internal temperature protection will not respond to the power on in the off state, if it has been turned on will stop charging and discharging. In this case, please wait for the product temperature to recover before using.
5.4.2 If the ambient temperature is normal, the battery may have been stored for too long causing the battery to run out of power, please plug in the charging cable to charge for at least 1 hour before use.
5.4.3 If the power station still cannot be turned on after taking the above measures, and there is no response when you press any button, the power station needs professional repair.
5.5 Short Discharge Time
5.5.1 The ambient temperature has a large impact on the battery discharge time, especially when the ambient temperature is below 0 degrees.
5.5.2 The product has a high number of cycles. The battery’s capacity will gradually decay as the number of cycles increases. Generally, when the rated cycle life is reached, the capacity is only 80% of the rated ca- pacity. This is a normal phenomenon and can continue to be used, but the discharge time will be shortened accordingly.
5.6 Wireless Charging Failure
5.6.1 Please turn on the wireless charging mode before use.
5.6.2 Wrong position: Please move the phone to the corresponding position.
5.6.3 In order to wireless charging function properly, please do not use more than 3-5mm thick phone case.
5.6.4 The surface is hot: Because the coil of wireless charging is hot, so there will be a little heat at the wireless charger. But please pay extra attention to the back of the phone can not have metal substances, which will lead to abnormal heating and can not be charged properly.
5.7 Product Overheating
When the power station with a larger load, the inverter at the top and the battery at the bottom will generate a certain amount of heat, the cooling fan will start to dissipate heat, even so, the shell will still have a certain temperature rise, the temperature of the shell will reach about 40 degrees in the area where the heat is concentrated at full load (rela- ted to the ambient temperature), this situation is normal.
5.8 DC and USB Output Error
5.8.1 Corresponding switch is not turned on:
Make sure that the DC and USB switches are pressed and the corres- ponding icons are lit.
5.8.2 Output overload protection:
When the DC and USB outputs are overloaded, the outputs will be au- tomatically cut off and the alarm icon will flash. In this case, you need to disconnect the power of the connected device, then press the DC and USB switch again to make sure the alarm icon is no longer flashing and you can use it again.
5.8.3 No response when the device is turned on and the correspon- dingicon flashes:
Some DC devices have a high starting current (such as car vacuum cle- aners), and the power station may not respond at the moment of star- ting, or it may enter the protection state in a short time. When you en- counter this situation, please judge and operate as described in 5.8.2.

WARRANTY

We provide a 30-day money-back guarantee and a 5-year warran- ty(please register on our website to activate the 3-year extended war- ranty).

ENERNOVA ETA Pro 1050Wh 1200W Portable Power Station - QR
Code https://linktr.ee/enernovawarranty?utm_source=qr_code

For FAQs and more information, please visit:enernovatech.com/pages/policy
ENERNOVA(CHINA) CO., LTD.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals