QUELL Q1400 Photoelectric Smoke Alarm User Manual
- June 14, 2024
- QUELL
Table of Contents
- QUELL Q1400 Photoelectric Smoke Alarm
- Product Information
- Product Usage Instructions
- FAQ (Frequently Asked Questions)
- Product Features
- Product Specifications
- Recommended Locations for Alarms
- Recommended Locations for Alarms
- Locations To Avoid
- Installation
- ACTIVATING THE ALARM
- Operation And Test
- Nuisance Alarms and Hush Function
- Alarm Visual and Audible Indicators
- BATTERY
- Cleaning Your Alarm
- Limitations Of Smoke Alarms
- Good Safety Habits
- What To Do When The Alarm Sounds
- Warranty & Contact Details
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
QUELL Q1400 Photoelectric Smoke Alarm
Product Information
Specifications
- Model: Q1400
- Electrical Rating: 2
- Sensor: Photoelectric
- Operating Temperature: Not specified
- Operating Humidity: Not specified
- Storage and Transport Conditions: Not specified
- Loud alarm: Yes
Product Usage Instructions
Product Features
The photoelectric smoke alarm is designed to detect visible particles associated with slow smouldering fires. It has a 10-year sealed battery and features an operational end-of-life indicator, which includes a chirp every 60 seconds and LED flash 2 times every 30 seconds to indicate when it is time to replace the alarm. The smoke alarm is a sealed unit, and any repairs should be done by returning it to the supplier.
Recommended Locations for Alarms
Laws on smoke alarms vary from state to state, so it is important to be aware of the requirements in your state. For more information, please refer to your local fire emergency services or state regulations.
For Ceiling Mounting:
Smoke, heat, and other combustion products rise to the ceiling and spread horizontally. Mounting the alarm in the center of the ceiling positions it closest to all points in the room.
For Wall Mounting:
Refer to Figure 1A, 1B, and 1C for recommended locations based on different floor plans and room types.
Recommended Locations for Alarms (Figures 1A, 1B, and 1C)
- Dining Room
- Kitchen
- Bedroom
- Living Room
- Hall
- Basement
- Master Bedroom
- Garage
- Family Room
- Workshop
Locations To Avoid
The smoke alarm should not be installed within 3m of cooking appliances. If desired, it should have an alarm silence feature.
FAQ (Frequently Asked Questions)
How often should I replace the smoke alarm?
The smoke alarm has a 10-year sealed battery. It is recommended to replace the alarm after this period or when the operational end-of-life indicator activates.
Can I install the smoke alarm in a mobile home?
Yes, you can install the smoke alarm in a mobile home. Please refer to the “Mobile Home Installation” section for specific instructions based on insulation conditions.
How often should I test the alarm?
It is recommended to test the alarm after the caravan or mobile home vehicle has been in storage, before each trip, and at least once a week during use.
10 Year sealed battery
Model: Q1400
Photoelectric smoke alarms are designed to detect visible particles
(associated with slow smouldering fires).
Quell® is a registered trademark of Kidde Australia Pty Ltd Copyright © 2021
Kidde Australia Pty Ltd. All rights reserved
©2021 Carrier. All Rights Reserved.
IMPORTANT: READ ALL INSTRUCTIONS BEFORE INSTALLATION AND KEEP THIS MANUAL NEAR THE ALARM FOR FUTURE REFERENCE
Thank you for purchasing this smoke alarm. It is an important part of your
family’s home safety plan. You can trust Quell to provide the highest quality
safety products.
Please take a few minutes to thoroughly read this user guide, and save it for
future reference. Teach children how to respond to the alarms, and that they
should never play with the smoke alarm.
If you have any questions about the operation or installation of your alarm,
please call our toll free Customer Service at 1800 654 435
Product Features
Model Q1400 is powered from a non-replaceable battery.
The smoke alarm ensures protection in the event of a power failure.
- Hush feature silences nuisance alarms for up to 10 minutes.
- The smoke alarm will sound a short beep about once every 60 seconds if the battery is low.
- The LED will flash every 60 seconds in the standby mode signifying that the alarm is receiving power
- Loud alarm sounder – 85 dB
- Test button checks smoke alarm operation.
- After ten (10) years of cumulative power up, the smoke alarm will “chirp” every 60 seconds and LED flash 2 times every 30 seconds. This is an “operational end of life” feature which will indicate that it is time to replace the alarm.
The smoke alarm is a sealed unit, return to supplier for any repairs.
Product Specifications
- Model Q1400
- Electrical Rating 3V sealed lithium battery
- Sensor Photoelectric
- Operating Temperature 0 °C to 40°C
- Operating Humidity Up to 93% Humidity (Non-Condensing)
- Storage and Transport Conditions -20° C to +60° C, 5-95%RH (non-condensing)
- Loud alarm 85 decibels at 3 metres
Recommended Locations for Alarms
Laws on smoke alarms vary from state to state and you should be aware of what the requirements are in your state – for more information please refer to your local fire emergency services or state regulations.
Recommended Locations
- In each room where an occupant sleeps with the door closed. (A closed door may prevent an alarm located outside the room from waking the occupant).
- In the immediate area of bedrooms and the exit path from all sleeping areas (Figure 1A).
- In stairwells, as stairwells act like chimneys for smoke heat. see Figure 1B.
- In any room where large electrical appliances are operated (e.g. portable heaters or humidifiers).
- If a hallway or room is more than 7m long install alarms at both ends.
- For maximum household protection see Figure 1C.
Things to Consider
For Ceiling Mounting:
Smoke, heat and other combustion products will rise to the ceiling and spread horizontally. Mounting the alarm in the centre of the ceiling positions it closest to all points in the room.
- When mounting an alarm on the ceiling, locate it at a minimum of 300mm from the side wall (Figure 2A).
- For sloped, peaked or cathedral ceilings the alarm should be placed between 500mm and 1500mm from the highest point of the ceiling (Figure 2B).
- The alarms in rooms with ceiling slopes greater than 1m in 8m horizontally, should be located on the high side of the room
(Figure 2B).
For Wall Mounting:
When mounting the alarm on the wall, use an interior wall with the top edge of the alarm at a minimum of 100mm and a maximum of 300mm below the ceiling (Figure 2A).
Recommended Locations for Alarms
Recommended Locations for Alarms
When mounting the alarm on a sloping ceiling, it should not exceed 1500mm away from the apex. The spacing of additional alarms, if any, should be based on a horizontal distance measurement, not a measurement along the slope of the ceiling (see Figure 2B )
- In rooms with open joists or beams not exceeding 300 mm, ceiling mounted alarms shall be located on the bottom of such beams. (See Figure 2C )
- Alarms installed on an open-joist ceiling shall have the smooth ceiling spacing reduced to no more than half of the listed spacing when measured at right angles to the solid joist. (See Figure 2C)
Mobile Home Installation:
For Well Insulated Mobile Homes
Install alarms as recommended on the previous pages.
In mobile homes that are not well insulated extreme heat or cold can be
transfered through poorly insulated walls and roofs. This may create a thermal
barrier which can prevent the smoke from reaching an alarm mounted on the
ceiling.
For Poorly Insulated Mobile Homes
Install the alarm on an inside wall with the top edge of the alarm at a
minimum of 100mm and a maximum of 300mm below the ceiling
(Figure 2A).
For minimum protection, install at least one alarm close to the bedrooms. For
additional protection, see Figure 1A.
! Warning: test your alarm operation after caravan or mobile home vehicle has
been in storage, before each trip and at least once a week during use.
Locations To Avoid
- Smoke alarms should not be installed within 0.9m(3 ft)
- of the door to a bathroom containing a tub or shower
- forced air supply ducts used for heating or cooling
- ceiling or whole house ventilating fans
- other high air flow areas
- Areas where curtains or other objects will block the sensor. Smoke must be able to reach the sensor to accurately detect conditions.
- Install at least 300mm away from a light fitting.
- No closer than 400 mm outside the circumference of a ceiling fan.
- Keep out of insect infested areas.
- Avoid excessively dusty, dirty or greasy areas.
- Do not install in areas where the temperature is colder than 0°C or hotter than 40°C.
- Do not install in areas where the relative humidity (RH) is greater than 93%.
- Normal cooking may cause nuisance alarms. If a kitchen alarm is desired, it should have an alarm silence feature and should not be installed within 3m of cooking appliances.
- Avoid dead air spaces such as the peak of an “A” frame ceiling.
“Dead Air” at the top may prevent smoke from reaching the alarm in time to provide early warning. Refer to Figure 2A and 2B.
Note: Smoke alarms are not to be used with detector guards unless the combination (alarm and guard) has been evaluated and found suitable for that purpose.
Installation
- To ensure aesthetic alignment of the alarm with the hallway or wall, the “A” line on the mounting bracket should be parallel with the hallway when ceiling mounting or horizontal when wall mounting.
- After selecting the proper smoke alarm location as described in on Page 2, attach the mounting bracket to the ceiling as shown in Figure 2A. For wall mounting see Figure 3A. Place the mounting plate on the wall; be sure the “A” line is horizontal (parallel to the floor). Use the screws and cavity fixings provided to secure the mounting bracket (use 3/16” drill bit for cavity fixings.).
- This alarm has a battery permanently sealed inside the alarm. No battery installation or maintenance is necessary.
Note: Extensive cycling between high and low temperatures will significantly reduce battery life. Long term exposure to high temperatures will degrade the battery over time. Chubb recommends locating this alarm in a controlled temperature environment (20-30°C) for optimum life.
ACTIVATING THE ALARM
Once activated, the battery will supply power to the alarm for the life of the alarm (10 years). Ensure that the mounting bracket is mount-ed correctly before installing the alarm on the mounting bracket.
-
To activate the alarm, install the alarm on the mounting bracket (Figure 3C) and rotate the alarm clockwise (as indicated on the alarm cover) until the alarm snaps into place.
WARNING: Alarm will not operate if it is not fixed on mounting plate. -
After installation/activation, test your alarm by depressing and holding down the Test button for a minimum of 1 second (or until the alarm sounds). This should sound the alarm. The alarm will sound at a low level to avoid discomfort. If the Test button is pressed for greater than 5 seconds, the alarm will sound at the full 85 decibels and may cause some discomfort.
Smoke Alarm Tamper Resist Feature
- To make the smoke alarm tamper-resistant, a tamper resist feature has been provided. To activate this feature you must break out the tamper-resist posts on the mounting plate (Figure 4A).Use a small screwdriver.
- Using this feature will deter children and others from removing the alarm from the mounting plate. With the blocks removed, the tamper-resist feature will be activated when the alarm is installed on the mounting plate.
- The tamper-resist tab will have to be released in order to remove alarm from mounting plate. Using a tool (small screwdriver) push the tab away from the mount-ing plate(Figure 4B) and rotate the alarm anti-clockwise in the “OFF” direction.
- After re-installation, test the alarm by depressing and holding down the Test button for several seconds. This should sound the alarm.
Operation And Test
The smoke alarm is operating once it is activated and testing is complete. When the smoke alarm senses smoke, the horn will sound a loud (85db) pulsating alarm( 3 beeps repeating).
Red LED indicator:
This smoke alarm features a red LED indicators that can be seen through the
Push-to-Test button.
RED
Red LED will flash every 60-70 seconds for 10 minutes following power on or
reset.
Indicating normal operation.
Red LED Flashes
Smoke alarm senses smoke and simultaneously sounds an audible alarm
Red LED Flashes once every 10 seconds
Smoke alarm is in hush mode.
Testing the smoke alarm
Test the unit, to ensure proper operation, by pressing the Test/Hush button
for at least 5 seconds (or until the unit sounds). This will sound the alarm
if the electronic circuitry, horn, and battery are working.
! CAUTION: Due to the loudness (85 decibels) of the alarm, stand at arm’s
length from the smoke alarm when testing. The alarm sounder is loud to alert
you to an emergency and can be harmful to hearing when you are too close.
Test the smoke alarm weekly and upon returning from holiday, or when the house
has been unoccupied for several days.
NOTE: WEEKLY TESTING IS RECOMMENDED.
! WARNING: If alarm sounder activates, and smoke alarm is not being tested, the smoke alarm is sensing smoke. THE ACTIVATION OF THE ALARM SOUNDER REQUIRES YOUR IMMEDIATE ATTENTION AND ACTION.
Nuisance Alarms and Hush Function
This alarm is designed to minimise nuisance alarms. Cigarette smoke will not normally cause the unit to alarm, unless the smoke is blown directly into the alarm. Combustion particles from cooking may set off the alarm if it is located too close to a cooking appliance. Large quantities of combustible particles are generated from spills or when boiling. Using the fan on a range hood which vents to the outside (non-recirculating type) will also help prevent nuisance alarms from occurring by removing these combustible products from the kitchen.
HUSH
If you know why the alarm is sounding, and you can verify that it is not a
life threatening situation, you can push the button on the alarm to silence
the alarm for up to 10 minutes. If the smoke is not too dense, that alarm will
silence. After the Hush period, the smoke alarm will automatically reset and
sound the alarm if particles of combustion are still present. You can use Hush
repeatedly until the air has been cleared of the condition causing the alarm.
Note: Dense smoke will override Hush and sound a continuous alarm. If no fire is present, check to see if one of the reasons listed in page 7. LOCATIONS TO AVOID may have caused the alarm. If a fire is discovered, exit the building and call the fire brigade.
Alarm Visual and Audible Indicators
The following tables describes the visual and audible alarm conditions the unit may report and illustrates how the unit will indicate normal standby, alarm and error conditions.
Alarm Mode | Visual Indications | Audible Indications |
---|---|---|
Smoke or Fire detected | Flashes every 0.5 seconds | 3 long beeps(ISO8201), |
repeating
Operational Mode| Visual Indications| Audible Indications| Note:
---|---|---|---
Normal Operation| Flash once every 60-70 seconds| None|
Test/Hush Button Press| Flash with each alarm pattern| Two sets of 3 long
beeps| Test/Hush button press will initiate test sequence
Smoke Alarm Hush| Flash once every 10 seconds| None (smoke alarm silenced)|
Alarm hush feature silences smoke alarm for approx. 10 minutes. See page 13
for additional instructions.
Low Battery| Flash once every 30 seconds| Chirp every 60 seconds| Remove, turn
off, replace alarm.
Fault Mode| No Flash| Chirp every 30 seconds| Remove, turn off replace alarm
End of Unit Life*| 2 Flash every 30 seconds| Chirps every 60 seconds| Remove,
turn off replace alarm
If you require further information please contact Service on 1800 654 435 or visit our website at www.quell.com.au.
BATTERY
BATTERY ACTIVATION
The battery automatically activates when the alarm is attached to the mounting
plate for the first time.
NOTE: One Lithium battery, permanently sealed inside the alarm, powers this unit; no battery installation or replacement is necessary for the life of the alarm.
IMPORTANT: Constant exposure to high or low humidity may reduce battery life.
! WARNING! DO NOT ATTEMPT TO OPEN THE ALARM FOR ANY REASON!Do not try to
repair the smoke alarm yourself. No serviceable parts included.
Low battery: This alarm is equipped with a low battery monitor circuit which
will cause the alarm to produce a single “chirp” approximately every 60
seconds and blink the Red LED every 30 seconds, for 30 days should the battery
become low.The unit must be replaced within 30 days of the first occurrence of
the “Low Battery Warning” to provide continuous alarm protection.
END OF UNIT LIFE: WHEN THE END OF UNIT LIFE STATUS (SEE SECTION 8: ALARM VISUAL AND AUDIBLE INDICATORS) HAS BEEN REACHED PLEASE PRESS AND RELEASE THE WHITE SMALL SQUARE BUTTON TO POWER OFF THE ALARM. DISPOSE OF ALARM AFTERWARDS. SEE BELOW IMAGE.
WARNING: ONCE THIS BUTTON IS PRESSED THE UNIT WILL NO LONGER DETECT SMOKE.
Cleaning Your Alarm
- YOUR ALARM SHOULD BE CLEANED AT LEAST ONCE A YEAR
- To clean your alarm, remove it from the mounting bracket. You can clean the interior of your alarm (sensing chamber) by using compressed air or a vacuum cleaner hose and blowing or vacuuming through the openings around the perimeter of the alarm. The outside of the alarm can be wiped with a damp cloth.
- After cleaning, reinstall your alarm and test your alarm by using the test button. If cleaning does not restore the alarm to normal operation the alarm should be replaced.
- After cleaning, reinstall your alarm and check that the Red LED flashes once every 60 seconds. Then test your alarm by using the test button.
Limitations Of Smoke Alarms
! Warning! Smoke alarms are devices that can provide early warning of possible fires; however, alarms have sensing limitations.
- Ionisation sensing alarms may detect invisible fire particles (associated with fast flaming fires) sooner than photoelectric alarms. Photoelectric sensing alarms may detect visible fire particles (associated with slow smouldering fires) sooner than ionisation alarms.
- Home fires develop in different ways and are often unpredictable.
- For maximum protection, subject to applicable legal requirements in each State and Territory, Quell recommends that both ionisation and photoelectric alarms be installed.
- Loose batteries, where fitted, must be of the specified type, in good condition and installed properly. AC only powered alarms will not operate if AC power has been cut off such as by an electrical fire, an open fuse or loss of mains supply. All alarms must be tested regularly to make sure the batteries and the alarm circuits are in good operating condition.
- Life safety from fire in residential occupancies is based primarily on early notification to occupants of the need to escape, followed by the appropriate egress actions by those occupants. If the alarm is located outside the sleeping room or on a different floor, it may not wake up a sound sleeper. The use of alcohol or drugs may also impair one’s ability to hear the smoke alarm. For maximum protection, a smoke alarm should be installed in each sleeping area on every level of a home.
- Smoke alarms cannot provide an alarm if smoke does not reach the unit. Therefore, smoke alarms may not sense fires starting in chimneys, walls, on roofs, on the other side of a closed door or on a different floor.
- Hearing impaired occupiers should consider fitting additional accessories to give a visual or tactile(Vibrating pad) alarm.
- Although smoke alarms can help save lives by providing an early warning of a fire, they do not prevent property damage. Home owners and renters should have adequate insurance to protect their property. If after reviewing this user guide you feel that your smoke alarm isdefective in any way,do not tamper with the unit. Refer to Section 14 Warranty and Contact Details.
Good Safety Habits
DEVELOP AND PRACTICE A PLAN OF ESCAPE:
- Install and maintain fire extinguishers on every level of the home and in the kitchen, basement and garage. Know how to use a fire extinguisher prior to an emergency.
- Make a floor plan indicating all doors and windows and at least two (2) escape routes from each room. Second story windows may need a rope or chain ladder.
- Have a family meeting and discuss your escape plan, showing everyone what to do in case of fire.
- Determine a place outside your home where you all can meet if a fire occurs.
- Familiarise everyone with the sound of the alarm and train them to leave your home when they hear it.
- Practice a fire drill at least every six months, including fire drills at night. Ensure that small children hear the alarm and wake when it sounds. They must wake up in order to execute the escape plan. Practice allows all occupants to test your plan before an emergency. You may not be able to reach your children. It is important they know what to do.
- Current studies have shown alarms may not awaken all sleeping individuals. It is the responsibility of individuals in the household that are capable of assisting others to provide assistance to those who may not be awakened by the alarm sound, or to those who may be incapable of safely evacuating the area unassisted.
What To Do When The Alarm Sounds
- Leave immediately by your escape plan. Every second counts, so don’t waste time getting dressed or picking up valuables.
- While leaving, don’t open any inside door without first feeling its surface. If hot, or if you see smoke seeping through cracks, don’t open that door! Instead, use your alternate exit. If the inside of the door is cool, place your shoulder against it, open it slightly and be ready to slam it shut if heat and smoke rush in.
- Stay close to the floor if the air is smoky. Breathe shallowly through a cloth, wet if possible.
- Once outside, go to your selected meeting place and make sure everyone is there.
- Call the fire department from your neighbour’s home – not from yours!
- Don’t return to your home until the fire officials say that it is all right to do so.
- There are situations where a smoke alarm may not be effective to protect against fire.
For instance:
- a) smoking in bed
- b) leaving children home alone
- c) cleaning with flammable liquids, such as petrol
Warranty & Contact Details
TEN YEAR WARRANTY
Warranty
Quell warrants to the original consumer purchaser that each new alarm will be
free from defects in materials and workmanship under normal use for a period
of 10 years from the date of purchase. To the extent permitted by law, Quell
agrees to repair or replace (at our discretion) any defective product on
presentation of the proof of purchase.
Australia warranty claims:
Where the goods are offered for sale in Australia, the benefits to the
consumer given by this warranty are in addition to other rights and remedies
of the consumer under the Australian Consumer Law and other applicable laws
relating to the goods. Our goods come with guarantees that cannot be excluded
under the Australian Consumer Law. You are entitled to a replacement or refund
for a major failure and compensation for any other reasonably foreseeable loss
or dam-age. You are also entitled to have the goods repaired or replaced if
the goods fail to be of acceptable quality and the failure does not amount to
a major failure.
New Zealand warranty claims:
Where the goods are offered for sale in New Zealand, the benefits to the
consumer given by this warranty are in addition to other rights and remedies
of the consumer under relevant New Zealand consumer pro-tection laws and other
applicable laws relating to the goods. Our goods come with guarantees that
cannot be excluded under relevant New Zealand consumer protection laws. You
are entitled to a replacement or refund for a major failure and compensation
for any other reasonably foreseeable loss or damage. You are also entitled to
have the goods repaired or replaced if the goods fail to be of acceptable
quality and the failure does not amount to a major failure.
Exclusions
Subject to non-excludable laws, this warranty does not cover:
- normal wear and tear to the product or parts
- batteries or other consumables included with this product (excluding sealed non replaceable battery models)
- damage to the product caused by accidents, misuse, abuse, lack of reasonable care, tampering or repair by a person not authorised by Quell
- any product that has not been installed, operated or maintained in accordance with the manual or operating instructions provided with the product
- any damage caused by improper power input or improper cable connection
- any indirect, special or consequential loss or damage of any kind
To make a claim
If a defect in the product appears within the time frame stated, you are
entitled to submit a warranty claim by returning your product to the address
shown below. Please contact Quell on the telephone numbers provided below,
Monday to Friday during 9.00AM – 5.00PM. When returning the product, please
ensure it is properly packaged so that no damage occurs during transit. Any
postage and packaging expenses required to return the product to Quell will be
at your cost.
Please provide the original or a copy of the proof of purchase. Also, please
make sure you have included an explanation of the problem.
If Quell elects to repair the product, please note that goods presented for
repair may be replaced by refurbished goods of the same type rather than being
repaired. Refurbished parts may be used to repair the goods.
This warranty is provided by:
Kidde Australia Pty Ltd
ABN 68 006 252 428
10 Ferntree Place, Notting Hill, Vic, 3168 Telephone: 1800 654 435
Website: www.quell.com.au
Made in China