HYPERLITE Space Series Wall Lamp Pack Light Instruction Manual

June 10, 2024
HYPERLITE

HYPERLITE Space Series Wall Lamp Pack Light

FEATURES & SPECIFICATIONS

HYPERLITE-Space-Series-Wall-Lamp-Pack-Light-fig-12

HYPERLITE-Space-Series-Wall-Lamp-Pack-Light-fig-1

PACKAGIN G INFORMATION

DISTRIBUTION

HYPERLITE-Space-Series-Wall-Lamp-Pack-Light-fig-2

INSTALLATION INSTRUCTIONS

Step 1: Open the cover by screwdriver.
Step 2: Fix the bottom plate to the junction plate.HYPERLITE-Space-
Series-Wall-Lamp-Pack-Light-fig-3
Step 3: Assembling the light source part on the bottom plate.
Step 4: Hinged the light source part, then screw the fixture with the bottom plate.HYPERLITE-Space-Series-Wall-Lamp-Pack-Light-
fig-4

SELECTABLE PHOTOCELL

  • Disable the photocellHYPERLITE-Space-Series-Wall-Lamp-Pack-Light-fig-5

BEFORE YOU INSTALL
Read these instructions completely and carefully.

WARNING: RISK OF ELECTRIC SHOCK

  • Turn power off before inspection, installation or removal.
  • Properly ground electrical enclosure.
  • Follow all NEC and local codes.
  • Use only UL or IEC approved wire for input/output connections.

Prepare Electrical Wiring

Electrical Requirements
The LED driver must be supplied with 100-277 VAC, 50/60 Hz per product label and connected to an individual properly grounded branch circuit, protected by a 15 or 20 ampere circuit breaker.

Grounding Instructions
The grounding and bonding of the overall system shall be done in accordance with National Electric Code (NEC) Article 600 and local codes.

Save These Instructions
Use only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.

Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

  • Please connect the input wire in correct way, white is ACN, black is ACL, green is GROUND connection.
  • Please also make sure the wire connection is fixed perfectly before using.HYPERLITE-Space-Series-Wall-Lamp-Pack-Light-fig-7

READ THOROUGHLY BEFORE INSTALLATION
WARNING: FIXTURES MUST BE GROUNDED and installed in accordance with the National Electrical Code and all local codes. Failure to do so may increase the RISK OF PERSONAL INJURY, PROPERTY DAMAGE, FIRE AND DEATH.

WARNING: Dangerous voltage exist within the unit and all precautions usually observed in handling high voltage equipment should be observed when replacing light engine or otherwise servicing luminaires. Disregarding this warning could result in electrical shock and possible injury to the individual installing or servicing this equipment. Installation, service and maintenance of luminaires should be done by a qualified licensed electrician.

CAUTION: To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards please read all warnings and instructions included with and on the fixture box and all fixture labels.

NOTE

  • This equipment is only for professional installation. Non-professional personnel shall not remove or install the equipment.
  • To avoid damage,falling,electric shock or fire, please do not modify the lamp or replace accessories without confirming with the supplier.
  • Maintenance/installation and replacement the lamps , please confirm to cut off the power supply, and the lamps have set up a cooling. Please make sure the lamps properly installed before processing power.
  • Ensure the accurate and reliable connection.
  • Ensure that the product around the vent, the lamp cannot violate any fire prevention regulations when using.

Carefully read these instructions before installing product and keep it for future reference. If you do not understand these instructions, before starting any work, contact
[email protected] or 855-688-7879.

FOOTCANDLE LIGHT GUIDE

Footcandles are the most common unit of measure used by lighting professionals to calculate light levels in businesses and outdoor spaces. A footcandle is defined the illuminance on a one square foot surface from a uniform source of light. The Illuminating Engineering Society (IES) recommends the following footcandle levels to ensure adequate illumination and safety for occupants. Below is a guideline for common areas to assist in achieving appropriate light levels with the greatest energy-efficiency.HYPERLITE-Space-Series-Wall-Lamp-
Pack-Light-fig-9

This guide is a collaborative effort of Energy Trust of Oregon and the Lighting Design Lab, Seattle, Washington.

HYPERLITE-Space-Series-Wall-Lamp-Pack-Light-fig-10

NOTES

  • This guide is based on information gathered from the IES ‘The Lighting Handbook’ 10th Edition. It is highly recommended that al lighting professionals refer to the full I ES guide when specifying lighting projects .
  • At least half of users are in the 25- 65 age range.
  • Horizontal-horizontal plane that average maintained foot-candles are measured.
  • Vertical—-vertical plane the average maintained foot-candles are measured.
  • It is the responsibility of the buyer to determine and provide appropriate lighting levels for each space.

LED High Bay Light

HYPERLITE-Space-Series-Wall-Lamp-Pack-Light-fig-8

www.hi-hyperlite.com
A good & brand new product. Congrats! Enjoy brighter life now.
Feel free to contact us
Email: [email protected]
Toll-free number: + 1 (855) 688 7879

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

HYPERLITE User Manuals

Related Manuals