HYPERLITE Lumens MARS SERIES LED FLOOD LIGHT Installation Guide
- June 5, 2024
- HYPERLITE
Table of Contents
HYPERLITE Lumens MARS SERIES LED FLOOD LIGHT
LED FLOOD LIGHT MARS Series
FEATURES & SPECIFICATIONS
The MARS series LED floodlight is designed to provide a cost-effective, energy-
efficient solution for illuminating building facades, sign lighting, wall
washing building exteriors, and landscape lighting. MARS luminaires deliver
a uniform, wide flood distribution.
Model | CES-LS-VN-30W | CES-LS-VN-50W | CES-LS-VN-70W | CES-LS-VN-100W |
---|---|---|---|---|
Lumens | 3300 lm | 5500 lm | 7700 lm | 11000 lm |
Model | CES-LS-VN-150W | CES-LS-VN-200W | CES-LS-VN-240W | |
Lumens | 18000 lm | 24000 lm | 28800 lm | |
CCT | 5000K | |||
CRI | >70 | |||
Beam angle | 120° | |||
Life span | >20,000 Hours | |||
Mounting | 1/2″ Knuckle, Trunnion, U-bracket | |||
Color | Bronze | |||
Input voltage | AC 120V | |||
Power factor | >0.9 | |||
Operating temperature | -22°F ~ 113°F (-30°C to 45°C) | |||
Listings | UL, cUL | |||
IP rating | IP 65 | |||
Warranty | 24 Months |
DIMENSIONS
1/2″ Knuckle Mounting
Trunnion Mounting
U-Bracket Mounting
INSTALLATION
1/2″ Knuckle Mounting
(Only available on 30w, 50w, 70w, and 100w light) ****
- Open junction box and run wiring into the box;
- Thread light body onto junction box using the 1/2-14 threads one knuckle;
- Connect wiring;
- Adjust the light head to the desired angle and tighten the hexagon screw;
With Wall Mounting Plate
(Only available on 30w, 50w,70w, and 100w light)
- Attach the mounting base to an appropriate location on the wall;
- Secure light body onto the mounting cover and connect wiring;
- Slide the mounting cover into the mounting base and secure it with the matching screws;
Trunnion Mounting
- Loosen light head adjustment screws with hex key;
- Securely attach light to the wall and connect wiring;
- Connect wiring;
- Rotate light head to the desired angle and tighten adjustment screws;
U-bracket Mounting
- Loosen light head adjustment screws with hex key;
- Securely attach light to wall and connect wiring;
- Adjust light head to desired angle and tighten hexagon screw;
Industrial LED Flood Lighting (MARS Series)
Features
UL&CUL No E483348 Suitable for Wet Locations.
ATTENTION
BEFORE YOU INSTALL
Read these instructions completely and carefully.
WARNING
RISK OF ELECTRIC SHOCK
- Turn the power off before inspection, installation or removal.
- Properly ground electrical enclosure.
- Follow all NEC and local codes.
- Use only UL or IEC-approved wire for input/output connections.
Prepare Electrical Wiring
Electrical Requirements
The LED driver must be supplied with 120 VAC, 60 Hz per product label and
connected to an individual properly grounded branch circuit, protected by a 15
or 20 ampere circuit breaker.
Grounding Instructions
The grounding and bonding of the overall system shall be done in accordance
with National Electric Code (NEC) Article 600 and local codes.
Save These Instructions
Use only in the manner intended by the manufacturer. If you have any
questions, contact the manufacturer.
Note:
This equipment has been tested and found to comply with the limits for a
Class A digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
- Please connect the input wire in the correct way, white is ACN, black is ACL, and green is the GROUND connection.
- Please also make sure the wire connection is fixed perfectly before using.
FOOTCANDLE LIGHT GUIDE
Footcandles are the most common unit of measure used by lighting professionals to calculate light levels in businesses and outdoor spaces. A footcandle is defined the illuminance on a one square foot surface from a uniform source of light. The illuminating Engineering Society (IES) recommends the following footcandle levels to ensure adequate illumination and safety for occupants. Below is a guideline for common areas to assist in achieving appropriate light levels with the greatest energy efficiency.
WAREHOUSING & STORAGE
Bulky Items-Large Labels| 10| | 5|
---|---|---|---|---
Small Items-Small Labels| 30| | 15|
Cold Storage| 30-40| 10-30| 10| 5-15
Open Warehouse| 30-40| 10-30| |
Warehouse w/Aisles| 30-40| 10-30| 10| 5-15
COMMERCIAL OFFICE
OpenOffice
|
40
| 30-50 @30″ Above Finished
Floor (AFF)
---|---|---
Pri v ate Office| 40| 30-50
@30″ AFF
C o nf e r e nc e R oo m
|
30
| | Matte surface refl ec tan c e
for the table 40%
recommended
Restroom| 1B| 75-30
Lunch & Break Room| 15| 5-20
EDUCATIONAL (SCHOOLS)
Classroom
Gymnasium
| 40| 30-50| | | @30″ AFF
---|---|---|---|---|---
Class I (Pro or Div. 1 College)| 125| | 30| |
Class II (Div. 2 or 3 College)| 80| | 20| |
Class Ill (High School)| 50| | 150| |
Class IV (Elementary)| 30| | 100| |
Audit o rium| 75| 3-10| 5| 2.5-10|
Corridor| 25| 10-40| | |
This guide is a collaborative effort of Energy Trust of Oregon and the Lighting Design Lab, Seattle, Washington.
INDUSTRIAL/MANUFACTURING
Assembly
Simple (Large Item)| 30| | 15| 15-60
Difficult (fine)| 100| 10-30| 10| 50-200
Component Manufacturing
Large| 30| 10-30| 30| 15-60
Medium| 70-80| 25-100| 50| 25-100
EXTERIOR
Parking (Covered)| 5| | | | 1FC min,10:1 Max to
Min Uniformity
---|---|---|---|---|---
Parking (Open) (Medium Activity)
Lighting Zone 3 (Urban)| 1.5| 75-3| 0.8| 0.4-1.6|
Lighting Zone 2 (suburban)| | 0.5-2| 0.6| 0.3-1.2|
Gas Station Canopy| 12.5| 10-15| | |
Safety (Building Exterior)| |
0.5-2
| | | If s e curity is an issu e
raise average lev e l to 3
RETAIL
General Retail (Ambient)| | 50| | |
---|---|---|---|---|---
Department Store| 40| 20-80| 15| 7.5-30|
P e rim e t e r| | | 75| 35-150|
Accent Lighting (Displays)
| | | | | 3-10 times greater than ambient light levels
AUTOMOTIVE
Showroom | 70-80 | 25-100 | 10 | 7.5-30 |
---|---|---|---|---|
Service Area | 50 | 25-10 | 30 | 15-30 |
Sales Lot (Exterior)
Lighting Zone 3 (Urban)| 20| 10-40| 20| 10-40
Lighting Zone 2 (Suburban)| 15| 7.5-30| 15| 7.5-30
GROCERY
Circulation | 20 | 10-40 | 7.5 | 3.5-15 |
---|---|---|---|---|
General Retail | 70-80 | 25-100 | 20 | 10-40 |
P e rim e t e r | 50 | 25-100 |
NOTES:
- This guide is based on information gathered from the IES ‘The Lighting Handbook’ 10th Edition. It is highly recommended that all Ughting professionals refer to the ful IES guide when specifying lighting projects .
- At.least half of users are in the 25 – 65 age range.
- The horizontal-horizontal plane that averages maintained foot candles is measured.
- Vertical-vertical plane the average maintained foot candles are measured.
- It is the responsibility of the to determine and provide appropriate lighting levels for each space.