HYPERLITE CES-LS-SR-40W LED Vapor Tight Light Instruction Manual

June 15, 2024
HYPERLITE

CES-LS-SR-40W LED Vapor Tight Light
Instruction Manual

CES-LS-SR-40W LED Vapor Tight Light

LED VAPOR TIGHT LIGHT
CAPSULE Series

FEATURES & SPECIFICATIONS

This linkable LED vapor tight Capsule series is the classic vapor tight design which is UL listed for wet location applications. The waterproof polycarbonate housing and a frosted polycarbonate lens are impact-resistant, and fully sealed against dust, moisture, fumes and insects. Perfect for when you need a light that can withstand industrial condition and harsh conditions.

Performance Data CES-LS-SR-40W CES-LS-SR-60W
General Lumens 5200 lm
Efficacy 130lm/W
CCT 5000K
Beam angle 120°
CRI >70
Life span >50,000 Hours
Color finish White
Electrical Power 40W
Input voltage AC 100-277V
Power factor >0.9
Temperature -22℉-113℉(-30ºC to 45ºC)
Mounting Surface Mounting
Listing UL, cUL
IP rating IP 65
Warranty 3 Years

PACKAGING INFORMATION

Model Qty/Ctn Net Weight Gross Weight CTN Size
CES-LS-SR-40W 1 4. 1±1 lbs 4. 8±1 lbs 51. 2″3.9″3.5″
4 16. 4±1 lbs 21. 3±1 lbs 52. 0″8.4″7.6″
CES-LS-SR-60W 1 5. 2±1 lbs 6. 1±1 lbs 51. 2″5.1″3.7″
4 20. 9±1 lbs 26. 7±1 lbs 52. 0″10.7″8.0″

INSTALLATION INSTRUCTIONS

Caution:

  1. Turn power Off during Installation.
  2.  Do not connect or disconnect under load3. Risk of fire.

Surface mounting

  1. Attach mounting brackets to surface using appropriate fasteners, or screws, anchors and washers provided. (Please note the center to center distance between brackets)
  2. Lift light into place and snap onto surface mounting brackets.
  3. Connect wiring.

Daisy-chain installation
NOTE: The maximum power is 700W for daisy-chain fixture. LED Vapor Tight Light (CAPSULE Series)
Attention
BEFORE YOU INSTALL
Read these instructions completely and carefully.

WARNING
RISK OF ELECTRIC SHOCK

  • Tum power off before inspection, installation or removal
  • Properly ground electrical enclosure
  • Follow all NEC and local codes.
  • Use only UL or IEC approved wire for input/output connections.

Prepare Electrical Wiring
Electrical Requirements
The LED driver must be supplied with 100-277 VAC, 50/60 Hz per product label and connected to an individual properly grounded branch circuit, protected by a 15 or 2O ampere circuit breaker.
Grounding Instructions
The grounding and bonding of the overall system shall be done in accordance with National Electric Code (NEC) Article 600 and local codes
Save These Instructions
Use only in the manner intended by the manufacturer If you have any questions, contact the manufacturer
Note This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to Cause harmful interference in which case the user will be required to correct the interference at his own expense Please connect the input wire in correct way,  white is ACN, black is ACL, green is GROUND connection. please also make sure the wire connection is fixed perfectly before using.

CERTIFICATE OF COMPLIANCE

CertificateNumber: E483348
Report Reference: E483348
Issue Date: 2020-JUNE-17
Additional Information:
See the UL Online Certifications Directory at www.ul.com/database for additional information.

  • Only those products bearing the UL Certification Mark should be considered as being covered by UL’s Certification and Follow-Up Service.
  •  Look for the UL Certification Mark on the product.

READ THOROUGHLY B EFORE INSTALLATION

WARNING! FIXTURES MUST BE GROUNDED and installed in accordance with the National Electrical Code and all local codes. Failure to do so may increase the RISK OF PERSONAL INJURY, PROPERTY DAMAGE, FIRE AND DEATH.
WARNING! Dangerous voltage exist within the unit and all precautions usually observed in handling high voltage equipment should be observed when replacing light engine or otherwise servicing luminares.
Disregarding this warning could result in electrical shock and possible injury to the individual installing or servicing this equipment. Installation, service and maintenance of luminaires should be done by a qualified licensed electrician.
CAUTION! To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards please read all warnings and instructions included with and on the fixture box and all fixture labels.
NOTE!

  • This equipment is only for professional installation. Non-professional personnel shall not remove or install the equipment.
  • To avoid damage, falling, electric shock or fire, please do not modify the lamp or replace accessories without confirming with the supplier.
  • Maintenance/installation and replacement the lamps, please confirm to cut off the power supply, and the lamps have set up a cooling. Please make sure the lamps properly installed before processing power.
  • Ensure the accurate and reliable connection.
  •  Ensure that the product around the vent, the lamp cannot violate any fire prevention regulations when using.

Carefully read these instructions before installing product and keep it for future reference. If you do not understand these instructions, before starting any work, contact [email protected] or (855)688-7879.
FOOTCANDLE LIGHT GUIDE
Footcandles are the most common unit of measure used by lighting professionals to calculate light levels in businesses and outdoor spaces. A footcandle is defined the ii luminance on a one square foot surface from a uniform source of light. The illuminating Engineering Society (IES) recommends the following footcandle levels to ensure adequate illumination and safety for occupants. Below is a guideline for common areas to assist in achieving appropriate light levels with the greatest energy-efficiency.

Buildinc Area &Task Average Range of Average Range of Comments
Maintained Maintained Maintained Maintained
Footcandles Footcandles Footcandles Footcandles
(Horizontal) (FC) (Horizontal) (FC) (Vertical) (FC) (Vertical) (FC)

WAREHOUSING & STORAGE 

Bulky Items-Large Labels| 10| | 5|
---|---|---|---|---
Small Items-Small Labels| 30| | 15|
Cold Storage| 30-40| 30-Oct| 10| 15-May
Open Warehouse| 30-40| 30-Oct| |
Warehouse w/Aisles| 30-40| 30-Oct| 10| 15-May

COMMERCIAL OFFICE

OpenOffice 40 30-50 @30″ Above Finished Floor (AFF)
Private Office 40 30-50 @30″ AFF
Conference Room 30 Matte surface reflectance or the table 40% recommended
Restroom 18 75-30
Lunch & Break Room 15 20-May

EDUCATIONAL (SCHOOLS)

Classroom 40 30-50 @30″ AFF
Gymnasium
Class I (Pro or Div. 1 College) 125 30
Class II (Div. 2 or 3 College) 80 20
Class Ill (High School) 50 150
Class IV (Elementary) 30 100
Auditorium 75 10-Mar 5 2.5-10
Corridor 25 Oct-40

This guide is a collaborative effort of Energy Trust of Oregon and the Lighting Design Lab, Seattle, Washington.

Buildinc Area &Task
g| Average| Range of| Average| Range of| Comments
---|---|---|---|---|---
Maintained| Maintained| Maintained| Maintained
Footcandles| Footcandles| Footcandles| Footcandles
(Horizontal) (FC)| (Horizontal) (FC)| (Vertical) (FC)| (Vertical) (FC)

INDUSTRIAL/MANUFACTURING

Assembly 15 15-60
Simple (Large Item) 30 10 50-200
Difficult (fine) 100 30-Oct
Component Manufacturing 1
Large 30 30-Oct 30 15-60
Medium 70-80 25-100 50 25-100

EXTERIOR

Parking (Covered) 5 1FC min, 10:1 Max to Min Uniformity
Parking (Open) (Medium Activity)
Lighting Zone 3 (Urban) 1.5 75-3 0.8 0.4-1.6
Lighting Zone 2 (suburban) 1 0.5-2 0.6 0.3-1.2
Gas Station Canopy 12.5 15-Oct
Safety (Building Exterior) 1 0.5-2 If security is an issue- raise

average level to 3

RETAIL

General Retail (Ambient)| | 50| | |
---|---|---|---|---|---
Department Store| 40| 20-80| 15| 7.5-30|
Perimeter| | | 75| 35-150|
Accent Lighting (Displays)| | | | | 3-10 times greater than ambient light levels

AUTOMOTIVE

Showroom 70-80 25-100 10 7.5-30
Service Area 50 25-10 30 15-30
Sales Lot (Exterior)
Lighting Zone 3 (Urban) 20 Oct-40 20 Oct-40
Lighting Zone 2 (Suburban) 15 7.5-30 15 7.5-30

GROCERY

Circulation 20 Oct-40 7.5 3.5-15
General Retail 70-80 25-100 20 Oct-40
Perimeter 50 25-100

BANKING

ATM 20 Oct-40 15 Vertical at face of ATM

NOTES:

  • This guide is based on information gathered from the IES ‘The Lighting Handbook’ 10th Edition.
    It is highly recommended that all lighting professionals refer to the full I ES guide when specifying lighting projects

  • At least half of users are in the 25- 65 age range.

  • Horizontal-horizontal plane that average maintained foot-candles are measured.

  • Vertical-vertical plane the average maintained foot-candles are measured.

  • It is the responsibility of the to determine and provide appropriate lighting levels for each space.

LED High Bay Light LED Wall Pack Light

Web: www.hi-hyperlite.com
Email: [email protected]
Tel: +1(855) 688 7879
www.hi-hyperlite.com
A good & brand new product. Congrats!
Enjoy brighter life now.
Feel free to contact us
Email: [email protected]
Toll-free number: +1(855) 688 7879

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

HYPERLITE User Manuals

Related Manuals