HYPERLITE CES-LS-SR-40W LED Vapor Tight Light Instruction Manual
- June 15, 2024
- HYPERLITE
Table of Contents
CES-LS-SR-40W LED Vapor Tight Light
Instruction Manual
CES-LS-SR-40W LED Vapor Tight Light
LED VAPOR TIGHT LIGHT
CAPSULE Series
FEATURES & SPECIFICATIONS
This linkable LED vapor tight Capsule series is the classic vapor tight design which is UL listed for wet location applications. The waterproof polycarbonate housing and a frosted polycarbonate lens are impact-resistant, and fully sealed against dust, moisture, fumes and insects. Perfect for when you need a light that can withstand industrial condition and harsh conditions.
Performance Data | CES-LS-SR-40W | CES-LS-SR-60W |
---|---|---|
General | Lumens | 5200 lm |
Efficacy | 130lm/W | |
CCT | 5000K | |
Beam angle | 120° | |
CRI | >70 | |
Life span | >50,000 Hours | |
Color finish | White | |
Electrical | Power | 40W |
Input voltage | AC 100-277V | |
Power factor | >0.9 | |
Temperature | -22℉-113℉(-30ºC to 45ºC) | |
Mounting | Surface Mounting | |
Listing | UL, cUL | |
IP rating | IP 65 | |
Warranty | 3 Years |
PACKAGING INFORMATION
Model | Qty/Ctn | Net Weight | Gross Weight | CTN Size |
---|---|---|---|---|
CES-LS-SR-40W | 1 | 4. 1±1 lbs | 4. 8±1 lbs | 51. 2″3.9″3.5″ |
4 | 16. 4±1 lbs | 21. 3±1 lbs | 52. 0″8.4″7.6″ | |
CES-LS-SR-60W | 1 | 5. 2±1 lbs | 6. 1±1 lbs | 51. 2″5.1″3.7″ |
4 | 20. 9±1 lbs | 26. 7±1 lbs | 52. 0″10.7″8.0″ |
INSTALLATION INSTRUCTIONS
Caution:
- Turn power Off during Installation.
- Do not connect or disconnect under load3. Risk of fire.
Surface mounting
- Attach mounting brackets to surface using appropriate fasteners, or screws, anchors and washers provided. (Please note the center to center distance between brackets)
- Lift light into place and snap onto surface mounting brackets.
- Connect wiring.
Daisy-chain installation
NOTE: The maximum power is 700W for daisy-chain fixture. LED Vapor Tight
Light (CAPSULE Series)
Attention
BEFORE YOU INSTALL
Read these instructions completely and carefully.
WARNING
RISK OF ELECTRIC SHOCK
- Tum power off before inspection, installation or removal
- Properly ground electrical enclosure
- Follow all NEC and local codes.
- Use only UL or IEC approved wire for input/output connections.
Prepare Electrical Wiring
Electrical Requirements
The LED driver must be supplied with 100-277 VAC, 50/60 Hz per product label
and connected to an individual properly grounded branch circuit, protected by
a 15 or 2O ampere circuit breaker.
Grounding Instructions
The grounding and bonding of the overall system shall be done in accordance
with National Electric Code (NEC) Article 600 and local codes
Save These Instructions
Use only in the manner intended by the manufacturer If you have any
questions, contact the manufacturer
Note This equipment has been tested and found to comply with the limits
for a Class A digital device, pursuant to part 15 of the FCC Rules These
limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a
residential area is likely to Cause harmful interference in which case the
user will be required to correct the interference at his own expense Please
connect the input wire in correct way, white is ACN, black is ACL, green is
GROUND connection. please also make sure the wire connection is fixed
perfectly before using.
CERTIFICATE OF COMPLIANCE
CertificateNumber: E483348
Report Reference: E483348
Issue Date: 2020-JUNE-17
Additional Information:
See the UL Online Certifications Directory at
www.ul.com/database for additional information.
- Only those products bearing the UL Certification Mark should be considered as being covered by UL’s Certification and Follow-Up Service.
- Look for the UL Certification Mark on the product.
READ THOROUGHLY B EFORE INSTALLATION
WARNING! FIXTURES MUST BE GROUNDED and installed in accordance with the
National Electrical Code and all local codes. Failure to do so may increase
the RISK OF PERSONAL INJURY, PROPERTY DAMAGE, FIRE AND DEATH.
WARNING! Dangerous voltage exist within the unit and all precautions
usually observed in handling high voltage equipment should be observed when
replacing light engine or otherwise servicing luminares.
Disregarding this warning could result in electrical shock and possible injury
to the individual installing or servicing this equipment. Installation,
service and maintenance of luminaires should be done by a qualified licensed
electrician.
CAUTION! To reduce the risk of death, personal injury or property damage
from fire, electric shock, falling parts, cuts/abrasions, and other hazards
please read all warnings and instructions included with and on the fixture box
and all fixture labels.
NOTE!
- This equipment is only for professional installation. Non-professional personnel shall not remove or install the equipment.
- To avoid damage, falling, electric shock or fire, please do not modify the lamp or replace accessories without confirming with the supplier.
- Maintenance/installation and replacement the lamps, please confirm to cut off the power supply, and the lamps have set up a cooling. Please make sure the lamps properly installed before processing power.
- Ensure the accurate and reliable connection.
- Ensure that the product around the vent, the lamp cannot violate any fire prevention regulations when using.
Carefully read these instructions before installing product and keep it for
future reference. If you do not understand these instructions, before starting
any work, contact service@hi-hyperlite.com
or (855)688-7879.
FOOTCANDLE LIGHT GUIDE
Footcandles are the most common unit of measure used by lighting
professionals to calculate light levels in businesses and outdoor spaces. A
footcandle is defined the ii luminance on a one square foot surface from a
uniform source of light. The illuminating Engineering Society (IES) recommends
the following footcandle levels to ensure adequate illumination and safety for
occupants. Below is a guideline for common areas to assist in achieving
appropriate light levels with the greatest energy-efficiency.
Buildinc Area &Task | Average | Range of | Average | Range of | Comments |
---|---|---|---|---|---|
Maintained | Maintained | Maintained | Maintained | ||
Footcandles | Footcandles | Footcandles | Footcandles | ||
(Horizontal) (FC) | (Horizontal) (FC) | (Vertical) (FC) | (Vertical) (FC) |
WAREHOUSING & STORAGE
Bulky Items-Large Labels| 10| | 5|
---|---|---|---|---
Small Items-Small Labels| 30| | 15|
Cold Storage| 30-40| 30-Oct| 10| 15-May
Open Warehouse| 30-40| 30-Oct| |
Warehouse w/Aisles| 30-40| 30-Oct| 10| 15-May
COMMERCIAL OFFICE
OpenOffice | 40 | 30-50 | @30″ Above Finished Floor (AFF) |
---|---|---|---|
Private Office | 40 | 30-50 | @30″ AFF |
Conference Room | 30 | Matte surface reflectance or the table 40% recommended | |
Restroom | 18 | 75-30 | |
Lunch & Break Room | 15 | 20-May |
EDUCATIONAL (SCHOOLS)
Classroom | 40 | 30-50 | @30″ AFF | ||
---|---|---|---|---|---|
Gymnasium | |||||
Class I (Pro or Div. 1 College) | 125 | 30 | |||
Class II (Div. 2 or 3 College) | 80 | 20 | |||
Class Ill (High School) | 50 | 150 | |||
Class IV (Elementary) | 30 | 100 | |||
Auditorium | 75 | 10-Mar | 5 | 2.5-10 | |
Corridor | 25 | Oct-40 |
This guide is a collaborative effort of Energy Trust of Oregon and the Lighting Design Lab, Seattle, Washington.
Buildinc Area &Task
g| Average| Range of| Average| Range of| Comments
---|---|---|---|---|---
Maintained| Maintained| Maintained| Maintained
Footcandles| Footcandles| Footcandles| Footcandles
(Horizontal) (FC)| (Horizontal) (FC)| (Vertical) (FC)| (Vertical) (FC)
INDUSTRIAL/MANUFACTURING
Assembly | 15 | 15-60 | ||
---|---|---|---|---|
Simple (Large Item) | 30 | 10 | 50-200 | |
Difficult (fine) | 100 | 30-Oct | ||
Component Manufacturing | 1 | |||
Large | 30 | 30-Oct | 30 | 15-60 |
Medium | 70-80 | 25-100 | 50 | 25-100 |
EXTERIOR
Parking (Covered) | 5 | 1FC min, 10:1 Max to Min Uniformity | |||
---|---|---|---|---|---|
Parking (Open) (Medium Activity) | |||||
Lighting Zone 3 (Urban) | 1.5 | 75-3 | 0.8 | 0.4-1.6 | |
Lighting Zone 2 (suburban) | 1 | 0.5-2 | 0.6 | 0.3-1.2 | |
Gas Station Canopy | 12.5 | 15-Oct | |||
Safety (Building Exterior) | 1 | 0.5-2 | If security is an issue- raise |
average level to 3
RETAIL
General Retail (Ambient)| | 50| | |
---|---|---|---|---|---
Department Store| 40| 20-80| 15| 7.5-30|
Perimeter| | | 75| 35-150|
Accent Lighting (Displays)| | | | | 3-10 times greater than ambient light
levels
AUTOMOTIVE
Showroom | 70-80 | 25-100 | 10 | 7.5-30 |
---|---|---|---|---|
Service Area | 50 | 25-10 | 30 | 15-30 |
Sales Lot (Exterior) | ||||
Lighting Zone 3 (Urban) | 20 | Oct-40 | 20 | Oct-40 |
Lighting Zone 2 (Suburban) | 15 | 7.5-30 | 15 | 7.5-30 |
GROCERY
Circulation | 20 | Oct-40 | 7.5 | 3.5-15 |
---|---|---|---|---|
General Retail | 70-80 | 25-100 | 20 | Oct-40 |
Perimeter | 50 | 25-100 |
BANKING
ATM | 20 | Oct-40 | 15 | Vertical at face of ATM |
---|
NOTES:
-
This guide is based on information gathered from the IES ‘The Lighting Handbook’ 10th Edition.
It is highly recommended that all lighting professionals refer to the full I ES guide when specifying lighting projects -
At least half of users are in the 25- 65 age range.
-
Horizontal-horizontal plane that average maintained foot-candles are measured.
-
Vertical-vertical plane the average maintained foot-candles are measured.
-
It is the responsibility of the to determine and provide appropriate lighting levels for each space.
LED High Bay Light LED Wall Pack Light
Web: www.hi-hyperlite.com
Email: service@hi-hyperlite.com
Tel: +1(855) 688 7879
www.hi-hyperlite.com
A good & brand new product. Congrats!
Enjoy brighter life now.
Feel free to contact us
Email: service@hi-hyperlite.com
Toll-free number: +1(855) 688 7879