FEATURES & SPECIFICATIONS
This linkable LED vapor tight Capsule series is the classic vapor-tight design which is UL listed for wet location applications. The waterproof polycarbonate housing and a frosted polycarbonate lens are impact-resistant and fully sealed against dust, moisture, fumes and insects. Perfect for when you need a light that can withstand industrial conditions and harsh conditions.
Peformance Data CES-LS-SR-40W CES-LS-SR-60W
General
| Lumens| 5200 lm| 7800 lm
Efficacy| 130lm/W
CCT| 5000K
Beam angle| 120°
CRI| >70
Life span| >50,000 Hours
Color finish| White
Electrical
| Power| 40W| 60W
Input voltage| AC 100-277V
Power factor| >0.9
Temperature| -22 ℉ -113 ℉ (-30ºC to 45ºC)
| Mounting| Surface Mounting
Listing| UL, cUL
IP rating| IP 65
Warranty| 3 Years
PACKAGING INFORMATION
Model Qty/Ctn Net Weight Gross Weight CTN Size
CES-LS-SR-40W
| 1| 4. 1±1 lbs| 4. 8±1 lbs| 51. 2″3.9″3.5″
4| 16. 4±1 lbs| 21. 3±1 lbs| 52. 0″8.4″7.6″
CES-LS-SR-60W
| 1| 5. 2±1 lbs| 6. 1±1 lbs| 51. 2″5.1″3.7″
4| 20. 9±1 lbs| 26. 7±1 lbs| 52. 0″10.7″8.0″
INSTALLATION INSTRUCTIONS
Surface mounting
- Attach mounting brackets to surface using appropriate fasteners, or screws, anchors and washers provided. (Please note the center to center distance between brackets)
- Lift light into place and snap onto surface mounting brackets.
- Connect wiring.
Daisy-chain installation
NOTE: The maximum power is 700W for daisy-chain
fixture.
LED Vapor Tight Light (CAPSULE Series)
BEFORE YOU INSTALL Read these instructions completely and carefully.
WARNING
SKOFELECTl!IN SHOCK
- Property und electrical enclosure.
- Follow oil NEC and local codes.
- LIii only UL or IEC aPl)n)Wd wino !Or input/output connections.
Save These Instructions
Use only in the manner intended by the manufacturer. If you have any
questions, contact the manufacturer.
Note: This equipment has been tested and found to comply with the limíts
for a Class A digital device, pursuant to part 15 of the FCC Rules.
these limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
Prepare Electrical Wiring
Electrical Requirements
The LED driver must be supplied with 100-277 VAC, 50/60 Hz per product label
and connected to an individual properly grounded branch circuit, protected by
a 15 or 20 ampere circuit breaker.
Grounding Instructions
The grounding and bonding of the overall system shall be done in accordance
with National Electric Code (NEC) Article 600 and local codes.
Please connect the input wire in the correct way, white is ACN, black is ACL,
and green is the GROUND connection. Please also make sure the wire connection
is fixed perfectly before using.
CERTIFICATE OF COMPLIANCE
- Certificate Number: E483348
- Report Reference: E483348
- Issue Date: 2020-JUNE-17
Additional Information:
See the UL Online Certifications Directory at
www.ul.com/database for additional information.
A Only those products bearing the UL Certification Mark should be considered
as being covered by UL’s Certification and Follow-Up Service. A Look for the
UL Certification Mark on the product.
READ THOROUGHLY BEFORE INSTALLATION
WARNING!
- FIXTURES MUST BE GROUNDED and installed in accordance with the National Electrical Code and ll local codes. Failure to do so may increase the RISK OF PERSONAL INJURY, PROPERTY DAMAGE, FIRE AND DEATH.
- Dangerous voltage exist within the unit and all precautions usually observed in handling high voltage equipment should be observed when replacing light engine or otherwise servicing luminares. Disregarding this warning could result in electrical shock and possible injury to the individual installing or servicing this equipment. Installation, service and maintenance of luminaires should be done by a qualified licensed electrician.
- CAUTION! To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards please read all warnings and instructions included with and on the fixture box and all fixture labels.
NOTE!
- This equipment is only for professional installation. Non-professional personnel shall not remove or install the equipment.
- To avoid damage, falling. electric shock or fire, please do not modify the lamp or replace accessories without confirming with the supplier.
- Maintenance/installation and replacement the lamps, please confirm to cut off the power supply, and the lamps have set up a cooling. Please make sure the lamps are properly installed before processing power.
- Ensure an accurate and reliable connection.
- Ensure that the product around the vent, the lamp cannot violate any fire prevention regulations when used.
Carefully read these instructions before installing the product and keep it for future reference. If you do not understand these instructions, before starting any work, contact service01@hi-hyperlite.com or (855)688-7879.
FOOTCANDLE LIGHT GUIDE
Footcandles are the most common unit of measure used by lighting professionals to calculate light levels in businesses and outdoor spaces. A footcandle has defined the illuminance on a one square foot surface from a uniform source of light. The illuminating Engineering Society (IES) recommends the following footcandle levels to ensure adequate illumination and safety for occupants. Below is a guideline for common areas to assist in achieving appropriate light levels with the greatest energy efficiency.
WAREHOUSING & STORAGE
Bulky Items-Large Labels | 10 | 5 | |
---|---|---|---|
Small Items-Small Labels | 30 | 15 | |
Cold Storage | 30-40 | 10-30 | 10 |
Open Warehouse | 30-40 | 10-30 | |
Warehouse w/Aisles | 30-40 | 10-30 | 10 |
COMMERCIAL OFFICE
Open Office
|
40
| 30-50 @30″ Above Finished
Floor (AFF)
---|---|---
Private Office| 40| 30-50
@30″ AFF
conference room
|
30
| | Matte surface
r e fle c tan c e
for the table 40%
recommended
Restroom| 18| 75-30
Lunch & Break Room| 15| 5-20
EDUCATIONAL (SCHOOLS)
Classroom
Gymnasium
| 40| 30-50| | | @30″| AFF
---|---|---|---|---|---|---
Class I (Pro or Div.1 College)| 125| | 30| | |
Class II (Div. 2 or 3 College)| 80| | 20| | |
Class Ill (High School)| 50| | 150| | |
Class IV (Elementary)| 30| | 100| | |
Auditorium
| 75| 3-10| 5| 2.5-10| |
Corridor| 25| 10-40| | | |
INDUSTRIAL/MANUFACTURING
Assembly
Simple (Large Item)| 30| | 15| 15-60
Difficult (fine)| 100| 10-30| 10| 50-200
Component Manufacturing
Large| 30| 10-30| 30| 15-60
Medium| 70-80| 25-100| 50| 25-100
EXTERIOR
Parking (Covered)
| ****
5
| | | | 1FC min, 10:1 Max to
Min Uniformity
---|---|---|---|---|---
Parking (Open) (Medium Activity)
Lighting Zone 3 (Urban)| 1.5| 75-3| 0.8| 0.4-1.6|
Lighting Zone 2 (suburban)| | 0.5-2| 0.6| 0.3-1.2|
Gas Station Canopy| 12.5| 10-15| | |
Safety (Building Exterior)
| | ****
0.5-2
| | | If s e curity is an issu e raise average lev e l t o 3
RETAIL
General Retail (Ambient) 50
Department Store| 40| 20-80| 15| 7.5-30|
P e rimeter| | | 75| 35-150|
Accent Lighting (Displays)
| | | | | 3-10 times greater than ambient light levels
AUTOMOTIVE
Sho w room | 70-80 | 25-100 | 10 | 7.5-30 |
---|---|---|---|---|
Service Ar e a | 50 | 25-10 | 30 | 15-30 |
Sales Lot (Exterior)
Lighting Zone 3 (Urban)| 20| 10-40| 20| 10-40
Lighting Zone 2 (Suburban)| 15| 7.5-30| 15| 7.5-30
GROCERY
Circulation | 20 | 10-40 | 7.5 | 3.5-15 |
---|---|---|---|---|
General Retail | 70-80 | 25-100 | 20 | 10-40 |
P e rimeter | 50 | 25-100 |
NOTES
-
This guide is based on information gathered from the IES ‘The Lighting Handbook 10th Edition.
-
It is highly recommended that all lighting professionals refer to the full lES guide when specifying lighting projects.
-
At least half of users are in the 25-65 age range.
-
Horizontakhorizontal plane that averages maintained foot-candles are measured.
-
Verticaertical plane the average maintained foot candles are measured.
-
It is the responsibility of the to determine and provide appropriate lighting levels for each space
-
LED High Bay Light
-
LED Flood Light
-
LED Grow Light
- LED Wall Pack Light
- Temporary Work Light
A good & brand new product. Congrats! Enjoy brighter life now. Feel free to
contact us
Email: service01@hi-hyperlite.com Toll-free
number: +1(855) 688 7879
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>