HYPERLITE RAY-105W RAY Series LED Linear High Bay Light User Manual

June 15, 2024
HYPERLITE

HYPERLITE RAY-105W RAY Series LED Linear High Bay Light

LED LINEAR HIGH BAY LIGHT RAY Series

FEATURES & SPECIFICATIONS

Dimension

PACKAGE CONTENTS

  • A. LED Fixture xl
  • B. User Manual xl
  • C. Hanging Chain x2
  • D. V Hook x2

PACKAGING INFORMATION

RAY-105W 105W 2 10.8±1 lbs 14.1±1 lbs 18.7‘ʼ13.8‘ʼ6.4‘ʼ
4 24.91±1 lbs 27.56±1 lbs 18.7‘ʼ14.4‘ʼ17.1‘ʼ
1 5.8±1 lbs 8.0±1 lbs 22.9‘ʼ13.8‘ʼ3.7‘ʼ
RAY-155W 155W 2 11.7±1 lbs 15.0±1 lbs 22.9‘ʼ13.8‘ʼ6.4‘ʼ
4 23.4±1 lbs 27.8±1 lbs 22.9‘ʼ13.8‘ʼ12.8‘ʼ
1 7.85±1 lbs 9.38±1 lbs 22.9‘ʼ13.7‘ʼ4.6‘ʼ
RAY-210W 210W 2 11.7±1 lbs 15.0±1 lbs 22.9‘ʼ13.8‘ʼ6.4‘ʼ
4 37.04±1 lbs 39.68±1 lbs 23.5‘ʼ14.4‘ʼ17.1‘ʼ
1 9.9±1 lbs 12.1±1 lbs 33.0‘ʼ13.8‘ʼ3.7‘ʼ
RAY-255W 255W 2 19.8±1 lbs 23.1±1 lbs 33.0‘ʼ13.8‘ʼ6.4‘ʼ
4 39.7±1 lbs 44.1±1 lbs 33.0‘ʼ13.8‘ʼ12.8‘ʼ
1 11.02±1 lbs 13.01±1 lbs 32.8‘ʼ13.7‘ʼ4.6‘ʼ
RAY-300W 300W 2 19.8±1 lbs 23.1±1 lbs 33.0‘ʼ13.8‘ʼ6.4‘ʼ
4 39.7±1 lbs 44.0±1 lbs 33.0‘ʼ13.8‘ʼ12.8‘ʼ
1 13.01±1 lbs 15.21±1 lbs 45.8‘ʼ13.7‘ʼ4.6‘ʼ
RAY-400W 400W 2 28.0±1 lbs 31.3±1 lbs 46.0‘ʼ13.8‘ʼ6.4‘ʼ

INSTALLATION

Suspension Mounting

  1. Take out the light and installation accessories. (V hook’ 2/hanging chain •2)
  2. First, buckle the V hook on the channel, and then let the V hook clip into the hole of the power box at the back of the light.
  3. Hang the chain on the wall hook to complete the installation
  4. Plug and play, light up your space.

Note: This product does not include a motion sensor accessory, please purchase it yourself if necessary. (The input voltage of the sensor must be 120-277 V if it is lower than this range, the power supply of the product will be at risk of burning out.)

Industrial LED Linear High Bay Lights (RAY Series)

BEFORE YOU INSTALL
  • ATTENTION Read these instructions completely and carefully.
  • WARNING RISK OF ELECTRIC SHOCK
  • Turn the power off before inspection, installation, or removal.
  • Properly ground electrical enclosure.
  • Follow all NEC and local codes.
  • Use only UL or IEC-approved wire for input/output connections.

Prepare Electrical Wiring

Electrical Requirements

  • The LED driver must be supplied with 120-277 VAC, 50/60 Hz per product label, and connected to an individual properly grounded branch circuit, protected by a 15 or 20-ampere circuit breaker.

Grounding Instructions

  • The grounding and bonding of the overall system shall be done under National Electric Code (NEC) Article 600 and local codes.

Save These Instructions

  • Use only in the manner intended by the manufacturer.
  • If you have any questions, contact the manufacturer.

Note: This equipment has been tested and found to comply with the limits for a Class A digital device, according to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used under the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

  1. Please accurately connect the input wire, black wire is L, the white wire is N, and the green wire is the ground connection.
    • Please also make sure the wire connection is fixed perfectly before using it.

Announcements:

  1. This equipment is only for professional installation. Non-professional personnel shall not remove or install the equipment.
  2. Please read the instruction manual before installation and keep it for future reference.
  3. To avoid damage, falling, electric shock, or fire, please do not modify the lamp or replace accessories without confirming with the supplier.
  4. Maintenance/installation and replacement of the lights, please confirm to cut off the power supply, and the lights have set up a cooling. Please make sure the lights have been properly installed before processing power.
  5. Ensure an accurate and reliable connection.
  6. Ensure that the product around the vent, and the light cannot violate any fire prevention regulations when using.

FOOTCANDLE LIGHT GUIDE

Footcandles are the most common unit of measure used by lighting professionals to calculate light levels in businesses and outdoor spaces. A footcandle is defined as the illuminance on a one-square-foot surface from a uniform source of light. The Illuminating Engineering Society (IES) recommends the following footcandle levels to ensure adequate illumination and safety for occupants. Below is a guideline for common areas to assist in achieving appropriate light levels with the greatest energy efficiency.

  • Average Maintained
    • Building Area & Task Footcandles (Horizontal) (FC) Range of
  • Maintained Footcandles (Horizontal) (FC) Average
    • Maintained Footcandles (Vertical) (FC) Range of
  • Maintained Comments Footcandles (Vertical) (FC)

WAREHOUSING & STORAGE

Bulky Items—Large Labels| 10| | 5|
---|---|---|---|---
Small Items—Small Labels| 30| | 15|
Cold Storage| 30-40| 10-30| 10| 5-15
Open Warehouse| 30-40| 10-30| |
Warehouse w/Aisles| 30-40| 10-30| 10| 5-15

COMMERCIAL OFFICE

Open Office| 40| 30-50 @30” Above Finished

Floor (AFF)

---|---|---
Private Office| 40| 30-50 @30” AFF

Conference Room

|

30

| | Matte surface reflectance  for the table 40% recommended
Restroom| 18| 75-30
Lunch & Break Room| 15| 5-20

EDUCATIONAL (SCHOOLS)

Classroom

Gymnasium

| 40| 30-50| | | @30” AFF
---|---|---|---|---|---
Class I (Pro or Div. 1 College)| 125| | 30| |
Class II (Div. 2 or 3 College)| 80| | 20| |
Class III (High School)| 50| | 150| |
Class IV (Elementary)| 30| | 100| |
Auditorium| 75| 3-10| 5| 2.5-10|
Corridor| 25| 10-40| | |

This guide is a collaborative effort of the Energy Trust of Oregon and the Lighting Design Lab, in Seattle, Washington.

  • Building Area & Task Average
    • Maintained Footcandles (Horizontal) (FC) Range of
  • Maintained Footcandles (Horizontal) (FC) Average
    • Maintained Footcandles (Vertical) (FC) Range of
  • Maintained Footcandles (Vertical) (FC) Comments

INDUSTRIAL/MANUFACTURING

Assembly

Simple (Large Item)| 30| | 15| 15-60
Difficult (fine)| 100| 10-30| 10| 50-200
Component Manufacturing
Large| 30| 10-30| 30| 15-60
Medium| 70-80| 25-100| 50| 25-100

EXTERIOR

Parking (Covered) 5 1FC min, 10:1 Max to Min Uniformity

Parking (Open) (Medium Activity)
Lighting Zone 3 (Urban)| 1. 5| 75-3| 0. 8| 0. 4-1. 6|
Lighting Zone 2 (suburban)| 1| 0. 5-2| 0. 6| 0. 3-1. 2|
Gas Station Canopy| 12. 5| 10-15| | |
Safety (Building Exterior)| 1| 0.5-2| | | If security is an issue- raise the average level to 3

RETAIL

General Retail (Ambient)| | 50| | |
---|---|---|---|---|---
Department Store| 40| 20 – 80| 15| 7.5-30|
Perimeter| | | 75| 35-150|
Accent Lighting (Displays)| | | | | 3-10 times greater than ambient light levels

AUTOMOTIVE

Showroom 70-80 25-100 10 7.5-30
Service Area 50 25-10 30 15-30

Sales Lot (Exterior)
Lighting Zone 3 (Urban)| 20| 10-40| 20| 10-40
Lighting Zone 2 (Suburban)| 15| 7.5-30| 15| 7.5-30

GROCERY

Circulation 20 10-40 7. 5 3. 5-15
General Retail 70-80 25-100 20 10-40
Perimeter 50 25-100

BANKING

  • ATM 20 10-40 15 Vertical at the face of ATM

NOTES:

  • This guide is based on information gathered from the IES ‘The Lighting Handbookʼ 10th Edition.
  • It is highly recommended that all lighting professionals refer to the full IES guide when specifying lighting projects.
  • At least half of users are in the 25 – 65 age range.
  • Horizontal—horizontal plane that average maintained foot-candles are measured.
  • Vertical—vertical plane the average maintained foot-candles are measured.
  • It is the responsibility of the to determine and provide appropriate lighting levels for each space.

warranty card

If you need any help or have any questions, please contact us.

  • Order Number: ——————————————
  • Light: ——————————————
  • Model: ——————————————
  • Name: ——————————————
  • Email: ——————————————
  • Problem: ——————————————
  • Date Of Manufacture: ——————————————

Note:

All returns must happen within 30 days of the receipt of that product or Hyperlite has the right to refuse the return.
Guidelines for items conditional return :

  • Item must be in original packaging.
  • Item must not have been installed or used.
  • Packaging material (i.e. wrapping, clam shells) must not have been destroyed or broken.

REMEDY:

Please note that products with different warranty periods provide different warranty services and the warranty time of all products is subject to Amazon listing.

  1. If the malfunction or damage of the products is caused by transportation, the buyer needs to contact us and provide evidence (video & pictures) within 15 days from the date of receiving. Providing the buyer fails to do so or no longer replies to us within 15 days after contact, the buyer will be responsible for any loss.
  2. If there are any quality problems over 30 days from the date of receipt, please contact HYPERLITE for a warranty with photos or videos showing product problems and HYPERLITE will provide maintenance services. The buyer shall bear the relevant expenses, and the specific expenses shall be subject to the seller’s instructions.

DISCLAIMER:

  • Please pay attention to the working temperature of light fixture. If the temperature that exceeds the usage limit of light fixture due to natural or man-made reasons cuases the damge of light fixture, the warranty policy won’t cover the lost

TERMS AND CONDITIONS:

  • This Limited Warranty is VOID in these situations: If purchaser or the user fails to comply with recommendations of Hyperlite; If any components are replaced with component of other manufacturers; If the product is operated outside the specified electrical values or is subject to abnormal use or stress, including under/over voltage conditions, excessive switching cycles, and operation in environmental conditions (e.g., ambient temperature) outside normal specified operating range.

LED High Bay Light

Documents / Resources

| HYPERLITE RAY-105W RAY Series LED Linear High Bay Light [pdf] User Manual
RAY-105W RAY Series LED Linear High Bay Light, RAY-105W, RAY Series LED Linear High Bay Light, LED Linear High Bay Light, Linear High Bay Light, High Bay Light, Bay Light, Light
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals