HYPERLITE OVAL Series LED Wall Pack Light Instruction Manual

June 12, 2024
HYPERLITE

HYPERLITE OVAL Series LED Wall Pack Light Instruction Manual
HYPERLITE OVAL Series LED Wall Pack Light

FEATURES & SPECIFICATIONS

Performance Data BWWP3-M-120W-U-50-PC
General Lumens
Efficacy 130 Im/W
cct 5000K
Beam angle Semi Cut-off
CRI >70
LED SMD 2835
Life span 50,000 hours
Color finish Bronze
Electrical Power
Input voltage AC120-277V.
Dimming o~10v.
Power factor 2095
Physical & Listing Temperature
Sensor Photocell
Mounting Wall Mount
Listing UL
IP rating P65
Warranty 3Years

PACKAGING INFORMATION

Model| Wattage| QTY| Net Weight| Gross Weight| CTN Size
---|---|---|---|---|---
BWWP3-M -120W-U -50- PC| 120W| 1PC| 8.3+1Ibs| 9.4+11bs| 15.9″ ” 11.0″ 7.5″
4PCS| 33.0+l I bs| 40.3+11bs| 23.2″
16.5″ * 16.5″

DISTRIBUTION

GENERAL WIRE DIAGRAM

INSTALLATION INSTRUCTIONS

Before You Install

Read these instructions completely and carefully.

WARNING

RISK OF ELECTRIC SHOCK.

  • Turn power off before inspection, installation or removal.
  • Properly ground electrical enclosure.
  • Follow all NEC and local codes.
  • Use only UL or IEC approved wire for inputioutput connections.
Save These Instructions

Use only in the manner intended by the manufacturer. If you have any question contact the manufacturer.

Prepare Electrical Wiring

Electrical Requirements
(Notincluded) and connect wires as per Fix the back housing to the wall and s bt Jon, instalas . The LED driver must be supplied with 120-277VAC, th d connect wires as per the wiring diagram urm power off before inspection, instalation or removal 50/60 Hz per product label and connected to an ‘e wiring diagram. « Properly ground electrical enclosure. individual property grounded branch circuit, « Follow all NEC and local codes. protected by a 15 or 20 ampere circut breaker.

Grounding Instructions
The grounding and bonding o he overall system Save These Instructions shall ba done in accordance with National Electric Use only in the manner intended by the manufacturer. Code (NEC) Article 600 and local codes.

Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

  • Please connect the input wire in correct way,white is ACN, black is ACL, yellow-green is ‘GROUND connection.
  • Please also make sure the wire connection is 0 f fixed perfectly before using.

APPLICATION

Application

FOOTCANDLE LIGHT GUIDE

Footcandies are the most cormmon unit of measue used by lighting professionals to calculate it levels in businesses and outdoor spaces. A footcande is defined the iluminance on a one square foot surface from a uniform source of iht. The lluminating Enginesring Society (ES) recommends the following footcandie levels to ensure adequate ilumination and safety for occupants. Below s a guideine for common areas to assist in achieving appropriate it levels with the greatest eneray-efficiency.

Building Area &Task| Average Maintained Footcandles (horizontal) (FC)| Range of Maintained Footcandles (Horizontal) (FC)| AverageMaintained Footcandles (Vertical) (FC)| Range of Maintained Footcandles (Vertical) (FC)| Comments
---|---|---|---|---|---
WAREHOUSING & STORAGE
Bulky Items—Large Labels| 10| | 5| |
Small Items—Small Labels| 30| | 15| |
Cold Storage| 30-40| 10-30| 10| 5-15|
Open Warehouse| 30-40| 10-30| | |
Warehouse w/Aisles| 30-40| 10-30| 10| 5-15|
COMMERCIAL OFFICE
Open Office| 40| 30-50| | | @30″ Above Finished Floor (AFF)
Private Office| 40| 30-50| | | @30″ AFF
Conference Room| 30| | | | Matte surface reflectancefor the table 40% recommended
Restroom| 18| 75-30| | |
Lunch & Break Room| 15| 5-20| | |
EDUCATIONAL (SCHOOLS)
| 40| 30-50| | | @30″ AFF
Gymnasium
Class I (Pro or Div. 1 College)| 125| | 30| |
Class II (Div. 2 or 3 College)| 80| | 20| |
Class III (High School)| 50| | 150| |
Class IV (Elementary)| 30| | 100| |
Auditorium| 75| 3-10| 5| 2.5-10|
Corridor| 25| 10-40| | |

Industrial Manufacturiing

Assembly

Simple (Large Item)| 30| | 15| 15-60|
Difficult (fine)| 100| 10-30| 10| 50-200|
Component Manufacturing
Large| 30| 10-30| 30| 15-60|
Medium| 70-80| 25-100| 50                           25-100

EXTEROR

Parking (Covered) 5 1FC min, 10:1 Max to Min Uniformity

Parking (Open) (Medium Activity)
Lighting Zone 3 (Urban)| 1.5| 75-3| 0.8| 0.4-1.6|
Liphting Zone 2 (suburban)| 1| 0.5-2| 0.6| 0.3-1.2|
Gas Station Canopy| 12.5| 10-15| | |
Safety (Building Exterior)| | 0.5-2| | | If security is an issue- raise average level to 3

RETAIL

General Retail (Ambient)| | 50| | |
---|---|---|---|---|---
Department Store| 40| 20— 80| 15| 7.5-30|
Perimmer| | | 75| 35-150|
Accent Lighting (Displays)| | | | | 3-10 times greater than ambient light levels

AUTOMOTIVE

Showroom| 70-80| 25-100| 10| 7.5-30|
---|---|---|---|---|---
| | | | |
Service Area| 50| 25-10| 30| 15-30|
Sales Lot (Exterior)
Lighting Zone 3 (Urban)| 20| 10-40| 20| 10-40|
Lighting Zone 2 (Suburban)| 15| 7.530| 15| 7.5-30|

GROCERY

Circulation 20 10-40 7.5 3.5-15
General Retail 70-80 25-100 20 10-40
Perimeter 50 25-100

BANKING

LED High Bay Light

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

HYPERLITE User Manuals

Related Manuals