Instructions for use
Application
Floodlight for recessed installation in compacted surfaces with ø 45 mm
provided by the customer. Drive-over luminaire from vehicles with pneumatic
tyres.
Please note:
Luminaire must not be used for installation in road lanes, where the fixture
is exposed to a horizontal strain due to braking, acceleration and change of
direction.
Product description
- In-ground LED luminaire without power supply unit
- Luminaire made of stainless steel
- Steel grade no 1.4301
- Installation bush made of polyamide
- Clear safety glass
- Reflector surface made of pure aluminium 3m water-resistant connecting cable 05RN8-F 2×1@ with implemented water stopper
- Safety class III 3
- Protection class IP 68 20 m
- Dust-tight and water pressure tight
- Maximum submersion depth 20 m
- Not suitable for permanent operation under water
- Impact strength IK10
- Protection against mechanical impacts < 20 joule
- Safety mark
- Conformity mark
- Weight: 0.5 kg
Safety
The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician. The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.
Lamp
Module connected wattage 1.1 W
Luminaire connected wattage 1.4 W
Rated temperature ta=25 °C
Ambient temperature ta max=65 °C
99 366K4
Colour temperature 4000 K
Colour rendering index CRI >80
Module luminous flux 205 lm
Luminaire luminous flux 133 lm
Luminaire luminous efficiency 95 lm/W
99 366K3
Colour temperature 3000 K
Colour rendering index CRI >80
Module luminous flux 205 lm
Luminaire luminous flux 133 lm
Luminaire luminous efficiency 95 lm/W
Please note:
The luminaire can only be operated with an operating device that fulfills the
requirements according to EN 61347-2-13. The maximum idle voltage of 60 V DC
must conform to SELV or SELV equivalent.
Installation
A separate power supply unit is required to operate the luminaire – see accessories. For installation in drilled holes, a recessed opening of ø 45 mm with a minimum depth of 100 mm is required to hold the installation sleeve. Press the installation sleeve firmly into the recessed opening. For installation in paved surfaces, the appropriate installation housing is 70 779 available. In this case, the polyamide installation sleeve is not used. The cable connection must be established on site with the correct protection class and safety class for the luminaire. We recommend that you use distribution box 70 730 or 71 053 for this purpose. To protect the luminaire power supply cable against damage we recommend you to use a PVC conduit on-site. A 24 V safety direct voltage source with a smoothed residual ripple of max. 10 % is required for the electrical connection of the luminaire – see accessories. If other safety direct voltage sources are used, an upstream fuse (max. 6 A) must be provided by the customer. The black wire is to be connected to the negative terminal, the red wire to the positive terminal on the power supply unit. Press the luminaire into the installation sleeve
Cleaning · Maintenance
After installation, the luminaire should first be cleaned. Building dust, residues from contact adhesives, paint splashes and rust film must be completely removed. Never use high pressure cleaners and cleaning implements made of normal steel, steel brushes or steel wool because they cause extraneous rust to form. When using stainless steel cleaners, please read the directions carefully. Cleaning agents containing hydrochloric acid and chlorides should never be used. We recommend cleaning the luminaires regularly.
Accessories
Power supply unit for LED luminaires 24 V DC Safety transformer according to
EN 61558/VDE 0570 part 2-6
70 564 Power supply unit for 5-15 W
70 465 Power supply unit for 10-25 W
70 565 Power supply unit for 20-35 W
70 566 Power supply unit for 30-50 W
70 567 Power supply unit for 40-75 W
70 169 Power supply unit for 70-150 W 230 V y 50-60 Hz
70 114 Power supply unit for 0-70 W
AC range: AC: 198-264 V y 50-60 Hz
DC range: DC: 176-275 V
The power supply units are also suitable for the operation of several LED luminaires. In this case, the maximum wattage of the power supply unit must not be exceeded.
70 779 Installation housing made of stainless steel
A separate instructions for use can be provided upon request.
70 730 Distribution box
The distribution box is meant for installation in the soil and allows a
junction from the supply cable to the luminaire and through-wiring to the next
luminaire. After the electrical connection the distribution box is filled up
with gel and closed.