BEGA 33035 Ceiling and Wall Luminaire Instruction Manual

June 12, 2024
BEGA

BEGA 33035 Ceiling and Wall Luminaire

Dimension

Dimension

Application

Lichtenstein ® Square
Ceiling and wall luminaire for many lighting tasks.
Ideal for places where a soft and uniform
lighting distribution is required.

Product description

Luminaire made of aluminium alloy,
aluminium and stainless steel
BEGA Unidure® coating technology
Opal glass satin matt
Reflector made of pure anodised aluminium
2 mounting holes ø 5.5mm
Distance apart 200mm
2 cable entries for through-wiring of mains supply cable ø 7-10.5mm
Connecting terminal and earth conductor terminal 2.5@
Lampholder E 27
Safety class I
Protection class IP 44
Protected against granular foreign bodies
≥ 1 mm and splash water
Impact strength IK02
Protection against mechanical
impacts < 0.2 joule
– Safety mark
– Conformity mark
Weight: 2.6 kg

Safety

The installation and operation of this luminaire are subject to national safety regulations.
Installation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation.
If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Lamps

Luminaire with screw base E 27
Lamp output max. 2 × 60 W
This product contains light sources of energy efficiency classes E, F

Supplied lamp
2 × BEGA LED lamp 13584
LED Retrofit 7 W · 805 lm · 3000 K

Luminaire efficiency: 44%

Additional BEGA LED lamps are available for this luminaire:

13 586 LED 7 W · 805 lm · 3000 K dimmable
13 588 LED 8 W · 1055 lm · 3000 K
13 590 LED 12 W · 1400 lm · 3000 K
13 592 LED 12 W · 1400 lm · 3000 K dimmable

Detailed technical and lighting data for the lamps can be found in the data sheets on our website.

Installation

Lead the mains supply cable through the cable entry into the luminaire back housing.
Note position of application of the luminaire “arrow down”.
Fix luminaire base with enclosed or any other suitable fixing material onto the mounting surface.
Be sure to use the gasket rings supplied.
Make earth conductor connection. Push silicone sleeves over the lines and make electrical connection. Insert lamps.
Snap the opal glass into the lower spring clips, centralise and push into the upper spring clips.

Relamping · Maintenance

Disconnect the electrical installation.
Pull glass out of the spring clips and remove from the luminaire back housing.
Clean the glass and luminaire housing using only suitable cleansers.
When cleaning please do not use high pressure cleaners.
Change the lamp.
Snap the glass into the lower spring clips, centralise and push into the upper spring clips.

Spares

Spare glass 11 002 759 .0
LED lamp 3000K 13 584
Lampholder 63 000 187