BEGA 50118.2K3 Lamp in LED Instruction Manual

June 12, 2024
BEGA

BEGA 50118.2K3 Lamp in LED

BEGA 50118.2K3 Lamp in LED

Application

Application

Recessed wall luminaire · indoor luminaire with crystal glass, inside white and metal housing. Luminaire with unshielded light for directing and conducting lighting.

Product description

Recessed ceiling luminaire »ACCENTA«
Die-cast zinc luminaire housing
Metal cover frame with safety glass, white
inside
Stainless steel finish
Cavity-wall box with 2 fixing claws and fixing
screws
Ceiling aperture ø 68 mm
Free space installation depth required 65 mm
Mains cable up to ø 10.5 mm, max. 3 × 1.5@
Connecting terminal 1.5@
Earth conductor connection
LED power supply unit
220-240 x 0/50-60 Hz
DC 176-264 V
Safety class I
r– Safety mark
 – Conformity mark
Weight: 0.27 kg
This product contains light sources of energy
efficiency classes D

Safety

The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician. The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

The electronic components installed in the
luminaire are protected against overvoltage in
accordance with DIN EN 61547.
To achieve an additional protection against
e.g. transients, etc. we recommend separate
overvoltage protection components.
You can find them on our website at
www.bega.com.

Lamp

Module connected wattage 1.9 W
Luminaire connected wattage 3 W
Rated temperature ta=25 °C
Ambient temperature ta max=40 °C
When installed in heat-insulating
material ta max=35 °C

50 118.2K27

Module designation LED-0676/927
Colour temperature 2700 K
Colour rendering index CRI >90
Module luminous flux 310 lm
Luminaire luminous flux 86 lm
Luminaire luminous efficiency 28,7 lm/W

50 118.2K3

Module designation LED-0676/930
Colour temperature 3000 K
Colour rendering index CRI >90
Module luminous flux 315 lm
Luminaire luminous flux 88 lm
Luminaire luminous efficiency 29,3 lm/W

Installation

 Luminaire housing must not be installed in heat-insulating material.
LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping.

Installation into solid walls

For this purpose a recess box, ø 68 mm and a recessed depth of min. 62 mm is necessary.

Installation into wall panels

A recessed opening of ø 68 mm is necessary to accept the cavity-wall box.
Recessed depth min. 65 mm.
The lateral distance between cavity-wall box and standard combustible building parts must be at least 40 mm.
The claws of the cavity-wall box catch the wall panel from the back side. If minimum thickness is less than 7 mm, it must be reinforced from the back side.
Maximum thickness of the panel must be no more than 35 mm.

Installation into wall panels

Pass the mains cable through a cable entry of the cavity-wall box and fit the cavity-wall box.
Make sure that the countersunk screws of the cavity-wall box are horizontal relative to the ground.
Connect the earth conductor to the link on the luminaire housing.
Make electrical connection to the terminal of the power supply unit.
Insert the luminaire into the cavity-wall box and use the two countersunk screws to adjust and secure it.
Use retention pins to mount the cover frame with glass on the luminaire housing such that the two rear magnets are seated on the countersunk screws.

Note:

This luminaire is supplied with a matching cavity-wall box.
If cavity-wall boxes of other manufacturers are used, they must be made of electrical insulating material such as plastic!

Through-wiring

Please note: Through wiring of the luminaire is only possible by means of an electronic box.
We recommend the use of a flush-mounted box Kaiser 1068-02 for flush-mounting and a cavity-wall box Kaiser 9268-94 for cavity wall mounting.

Cleaning · Maintenance

Clean luminaire regularly with solvent-free cleansers from dirt.
Defective glass must be replaced.

Replacement of the LED module

The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
The module can be replaced by qualified persons using standard tools.
Disconnect the system and open the luminaire.
Please follow the installation instructions for the LED module.
Defective glass must be replaced. Close the luminaire.

Spares

Glass/Trim frame 20 000 030M1
LED power supply unit DEV-0231/350
LED module 2700 K LED-0676/927
LED module 3000 K LED-0676/930

Customer Support

BEGA Gantenbrink-Leuchten KG · Postfach 3160 ·
58689 Menden ·
info@bega.com ·
www.bega.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals