BEGA 50285.2 LED Recessed Wall Luminaire

Recessed wall luminaire for indoor use

BEGA 50285.2 LED Recessed Wall Luminaire

Instructions for use

Application

Recessed wall luminaire · indoor luminaire with crystal glass, inside white and metal housing.
Luminaire with unshielded light for directing and conducting lighting.

Product description

Recessed ceiling luminaire »ACCENTA« Die-cast zinc luminaire housing
Metal cover frame with safety glass, white inside
Stainless steel finish
Cavity-wall box with 2 fixing claws and fixing screws
Ceiling aperture ø 68 mm
Free space installation depth required 65 mm
Mains cable up to ø 10.5 mm, max. 3 × 1.5@
Connecting terminal 1.5@
Earth conductor connection
LED power supply unit 220-240 V 0/50-60 Hz DC 176-264 V
Safety class I

Safety mark
****Conformity mark
Weight: 0.26 kg
This product contains light sources of energy efficiency classes D

Safety

The installation and operation of this luminaire are subject to national safety regulations.
Installation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation.
If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.

Lamp

Module connected wattage 1.9 W
Luminaire connected wattage 3 W
Rated temperature ta = 25 °C
Ambient temperature ta max = 40 °C
When installed in heat-insulating material ta max = 35 °C

50 285.2 K27

Module designation LED-0676/927
Colour temperature 2700 K
Colour rendering index CRI > 90
Module luminous flux 310 lm
Luminaire luminous flux 91 lm
Luminaire luminous efficiency 30,3 lm / W

50 285.2 K3

Module designation LED-0676/930
Colour temperature 3000 K
Colour rendering index CRI > 90
Module luminous flux 315 lm
Luminaire luminous flux 93 lm
Luminaire luminous efficiency 31 lm / W

Installation

Luminaire housing must not be installed in heat-insulating material.
LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during installation or revamping.
Installation into solid walls
For this purpose a recess box, ø 68 mm and a recessed depth of min. 62 mm is necessary.
Installation into wall panels
A recessed opening of ø 68 mm is necessary to accept the cavity-wall box.
Recessed depth min. 65 mm.
The lateral distance between cavity-wall box and standard combustible building parts must be at least 40 mm.
The claws of the cavity-wall box catch the wall panel from the back side. If minimum thickness is less than 7 mm, it must be reinforced from the back side.
Maximum thickness of the panel must be no more than 35 mm.

BEGA 50285.2 LED Recessed Wall Luminaire - fig1

Pass the mains cable through a cable entry of the cavity-wall box and fit the cavity-wall box.
Make sure that the countersunk screws of the cavity-wall box are horizontal relative to the ground.
Connect the earth conductor to the link on the luminaire housing.
Make electrical connection to the terminal of the power supply unit.
Insert the luminaire into the cavity-wall box and use the two countersunk screws to adjust and secure it.
Use retention pins to mount the cover frame with glass on the luminaire housing such that the two rear magnets are seated on the countersunk screws.

Note:
This luminaire is supplied with a matching cavity-wall box.
If cavity-wall boxes of other manufacturers are used, they must be made of electrical insulating material such as plastic!
Through-wiring
Please note: Through wiring of the luminaire is only possible by means of an electronic box.
We recommend the use of a flush-mounted box Kaiser 1068-02 for flush-mounting and a cavity-wall box Kaiser 9268-94 for cavity wall mounting.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt.
Defective glass must be replaced.
Replacement of the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
The module can be replaced by qualified persons using standard tools.
Disconnect the system and open the luminaire.
Please follow the installation instructions for the LED module.
Defective glass must be replaced.
Close the luminaire.

Spares

  • Glass/Trim frame
  • LED power supply unit
  • LED module 2700 K
  • LED module 3000 K

BEGA logo

BEGA Gantenbrink-Leuchten KG
Postfach 31 60
58689 Menden
info@bega.com
www.bega.com

Documents / Resources

| BEGA 50285.2 LED Recessed Wall Luminaire [pdf] Instruction Manual
50285.2, 50285.2K3, 50285.2 LED Recessed Wall Luminaire, LED Recessed Wall Luminaire, Recessed Wall Luminaire, Wall Luminaire, Luminaire
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals