BEGA 31075 LED Wall Luminaire Instruction Manual
- June 12, 2024
- BEGA
Table of Contents
Wall luminaire 31 075 IP 44
Instructions for use
Application
Wall luminiaire made of die cast aluminium and hand-blown three-ply opal
glass.
A luminaire with uniform light distribution for a variety of lighting tasks.
Product description
Luminaire made of aluminium alloy, aluminium and stainless steel BEGA Unidure®
coating technology Opal glass
Silicone gasket
Mounting plate with 2 fixing holes ø 5.2 mm · 70 mm spacing 1 cable entry for
mains supply cable up to ø 10,5 mm
Connecting terminal 2.5@ with plug connection
Earth conductor connection
LED power supply unit 220-240 V x 0/50-60 Hz
DC 176-280 V
BEGA Thermal Switch®
Temporary thermal shutdown to protect temperature-sensitive components
Safety class I
Protection class IP 44
Protected against granular foreign bodies ≥ 1 mm and splash water
Impact strength IK06
Protection against mechanical impacts < 1 joule
– Safety mark
**** – Conformity mark
Weight: 3.7 kg
This product contains light sources of energy efficiency classes C
Lamp
Module connected wattage | 13.3 W |
---|---|
Luminaire connected wattage | 15.6 W |
Rated temperature | ta = 25 °C |
Ambient temperature | ta max = 50 °C |
31 075 K3
Module designation | LED-0904/830 |
---|---|
Colour temperature | 3000 K |
Colour rendering index | CRI > 80 |
Module luminous flux | 2750 lm |
Luminaire luminous flux | 1992 lm |
Luminaire luminous efficiency | 127,7 lm / W |
Safety
The installation and operation of this luminaire are subject to national
safety regulations.
Installation and commissioning may only be carried out by a qualified
electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation.
If subsequent modifications are made to the luminaire, the person responsible
for these modifications shall be considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we
recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.
Installation
LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during
installation or relamping.
Undo screw at wall box and remove the mounting plate.
Lead the mains supply cable through the cable entry of the mounting plate.
Note position of application of the mounting plate “arrow down”.
Fix the mounting plate with enclosed or any other suitable fixing material
onto the mounting surface.
Be sure to use the gasket rings supplied.
Make earth conductor connection.
Push silicone sleeves over the lines and make electrical connection to
terminal (plug connection).
Make earth conductor connection between luminaire housing and mounting plate.
Push plug into coupler as far as it will go.
Place the luminaire onto the mounting plate, adjust and fix it.
Screw glass with gasket into luminaire housing.
Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted.
The module can be replaced by qualified persons using standard tools.
Disconnect the system and open the luminaire.
Please follow the installation instructions for the LED module.
Inspect and, if necessary, replace the luminaire gaskets.
Defective glass must be replaced.
Close the luminaire.
Spares
Spare glass with gasket | 11 002 540 41 |
---|---|
LED power supply unit | DEV-0136/500 |
LED module 3000 K | LED-0904/830 |
Gasket glass | 83 000 646 |
BEGA Gantenbrink-Leuchten KG
Postfach 31 60
58689 Menden
info@bega.com
www.bega.com
References