BEGA 31 058 Wall Luminaire Instruction Manual

June 12, 2024
BEGA

BEGA 31 058 Wall Luminaire

Product Information

Product Name Wandleuchte Wall luminaire Applique
Model Number 31 058
IP Rating IP44
Application Wall luminaire with shielded light source for many lighting tasks

on or in buildings.

Instructions for use

Application
Wall luminaire with shielded light source for many lighting tasks on or in buildings.

Lamp

  • Module connected wattage: 3 W
  • Luminaire connected wattage: 4.1 W
  • Rated temperature: ta = 25 °C
  • Ambient temperature: ta max = 45 °C

31 058 K3

  • Module designation: LED-0422/830
  • Colour temperature: 3000 K
  • Colour rendering index: CRI > 80
  • Module luminous flux: 525 lm
  • Luminaire luminous flux : 306 lm
  • Luminaire luminous efficiency: 74,6 lm / W

Product Description

  • Luminaire made of copper and stainless steel Opal glass with screw neck
  • Silicone gasket
  • Wall mounting with a mounting plate made of stainless steel, Steel grade number 1.4301 Mounting plate with 2 fixing
  • holes ø 4.5 mm · 52 mm spacing
  • 1 cable entry for mains supply cable up to ø 10,5 mm
  • Connection terminal 2.5@
  • Earth conductor connection
  • BEGA Ultimate Driver®
  • LED power supply unit
  • 220-240 V x 0/50-60 Hz
  • DC 176-264 V
  • BEGA Thermal Switch®
  • Temporary thermal shutdown to protect temperature-sensitive components
  • Safety class I
  • Protection class IP 44
  • Protected against granular foreign bodies
  • ≥ 1 mm and splash water
  • Impact strength IK07
  • Protection against mechanical
  • impacts < 2 joule
  • – Safety mark
  • – Conformity mark
  • Weight: 1.3 kg
  • This product contains light sources of energy efficiency class(es) C

DIMENSION

BEGA-31-058-Wall-Luminaire-fig-1

Light technique

  • Part of the light shines upwards through a slit in the reflector shield.
  • The shape of the luminaire thus remains visible, even in the dark.

Safety:

The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician. The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection:

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547. To achieve an additional protection against e.g. transients, etc., we recommend separate overvoltage protection components. You can find them on our website at www.bega.com.

Installation

  • Please use the protective gloves provided for the installation to prevent fingerprints on the luminaire.
  • LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping.
  • Remove glass with reflector from the luminaire housing.
  • Undo screw at wall box and remove the mounting plate.
  • Lead the mains supply cable through the cable entry of the mounting plate.
  • Note position of application of the  mounting plate “arrow down”.
  • Fix the mounting plate with enclosed or any other suitable fixing material onto the mounting surface.
  • Make earth conductor connection.
  • Push silicone sleeves over the lines  and make electrical connection.
  • Make earth conductor connection between luminaire housing and mounting plate.
  • Note position of application of the luminaire  “arrow down”.
  • Place wall bracket onto mounting plate, adjust and fix with screw.
  • Screw glass with top reflector and gasket into the luminaire housing.

Replacing the LED module

  • The designation of the LED module is noted on a label in the luminaire.
  • The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
  • The module can be replaced by qualified persons using standard tools.
  • Disconnect the system and open the luminaire. Please follow the installation instructions for the LED module.
  • Inspect and, if necessary, replace the luminaire gaskets.
  • Defective glass must be replaced.
  • Close the luminaire.

Copper:

The luminaire parts made of solid copper are delivered with the metal’s natural surface color. Time and weather factors create the natural patina characteristic for copper.

Spares

Spare Part Part Number
Spare glass with gasket 11 002 563 41
LED power supply unit DEV-0303/350
LED module 3000 K LED-0422/830
Gasket glass 83 000 734

BEGA Gantenbrink-Leuchten KG
Postfach 31 60
58689 Menden
info@bega.com
www.bega.com