SOVELOR F30, F60, F80 Climate Solutions User Manual

June 12, 2024
SOVELOR

SOVELOR F30, F60, F80 Climate Solutions

CONTROL BOARD

  1. HOT AIR OUTFLOW
  2. CHIMNEY
  3. COOLING FAN
  4. COMBUSTION CHAMBER
  5. BURNER
  6. THERMOSTATS L2 BOX
  7. FUEL TANK
  8. CONTROL PANEL

CONTROL PANEL

SOVELOR-F30,-F60,-F80-Climate-Solutions-fig- \(3\)

  • a. HEATING-VENTILATION SWITCH
  • b. VOLTAGE LAMP
  • a. BURNER LIGHT
  • d. OVERHEAT THERMOSTATS CONTROL LAMP, L2
  • e. ROOM THERMOSTAT
  • f. SAFETY THERMOSTAT RESET BUTTON, L2
  • g. BURNER RESET BUTTON/LAMP
  • h. FUEL RESERVE INDICATOR

IMPORTANT
Before using the space heater, carefully read all of the instructions and follow them scrupulously. The manufacturer cannot be held responsible for damage to persons and/or property caused by improper use of the equipment. This instruction manual is an integral part of the equipment and must therefore be stored carefully and passed on with the unit in the event of a change of ownership.

DESCRIPTION

Space heaters described in this manual, are designed for use in medium to large-sized rooms and buildings where a fixed heating system is required for indoor use

The air required for combustion is sucked directly by the burner (5) installed on the heater, and is supplied from inside the room to be heated. In this case, the room must be well ventilated to guarantee sufficient exchange of air.
The flow of hot air is moved by the high-efficiency fan (3): air is heated by the thermal energy generated during la combustion and heat from the smoke is transmitted to the fresh air through the metal walls of the sealed combustion chamber and the heat exchanger. After the combustion products are cooled, they are conveyed to a discharge duct and eliminated through a chimney or flue large enough to guarantee their removal.

Air outlet (1), supplied as an accessory and not included with heater, is provided with adjustable louvres to allow proper direction of air flow The space heaters can work with burners having ON-OFF work modes and can run on diesel fuel.

Warning
Only burners approved by the manufacturer and listed in the “TECHNICAL SPECIFICATION TABLE” can be used. The heater’s certification and warranty will lapse if the burner is replaced with a non-original model, even if it has similar specifications.

All of the space heaters are fit with an electronic device that controls the flame and with:

  • safety devices (safety thermostat with manual reset, flame control) that trip in case of serious malfunctions and cause a safety stop. In this case the heater stops, button (d) lights with a steady red light (Stop Light) and the heater can resume operation only after the cause of the stop has been identified and eliminated;
  • control devices (fan thermostat, burner thermostat) that trip in case of minor operating faults or supply faults, causing temporary stop of the space heater. In this case, the heater will restart automatically when the required condition is restored.

The section “TROUBLESHOOTING” describes all possible operating faults and their possible remedies.

CONDITIONS OF SUPPLY

The heater is delivered with parts already assembled: heater body, burner and room thermostat

Warning
Prior to start heating, the space heater shall be assembled in full.

All assembly operations shall be performed by professionally qualified personnel only.

The following are also supplied:

  • use and maintenance manuals for
    • space heater
    • burner
  • manuals with drawings and spare part lists:
    • space heater
    • burner

Warning
All documents provided constitute an integral part of the unit. The documents should therefore be looked after with care and supplied with the unit in the event of a change in ownership.

Parts are to be transported and moved using either a manual or automatic forklift truck with sufficient load capacity.

Warning
Never try to lift the heater manually. Doing so could cause serious physical injury.

GENERAL ADVICE

The space heater must be installed, adjusted, and used in conformity to national and local laws and regulations for its operation. General guidelines:

  • • Follow the instructions in this booklet very carefully;
    • The heater is not installed in an area where there is a high risk of fire or explosions;

  • • Keep inflammable material at a safe distance from the heater (minimum 3 metres);
    • Check that there is no overheating of walls, ceilings or floors made of inflammable materials,
    • All precautions have been taken to prevent fires;
    • The room being heated must be sufficiently ventilated so that the heater has enough air to function properly;
    • The heater must be near a chimney or chimney flue and an electrical panel conforming to declared specifications;
    • Check the heater before switching it on and at regular intervals during its use;
    • After use, make sure the disconnecting switch is off.
    When using any type of space heater it is obligatory:

  • not to exceed the maximum heat output level of the furnace (“TECHNICAL SPECIFICATION TABLE”);

  • make sure that the air flow is not below the rated level; check that there are no obstacles or obstructions to the air suction and/or delivery ducts, such as sheets or covers on the equipment, walls or large objects near the heater.

Warning
This unit may not be used by persons (including children) with reduced physical, sensorial or mental capacities or with limited experience and familiarity unless they are under supervision or instructed on how to use the unit by the person responsible for its safety.

INSTALLATION INSTRUCTIONS

Warning
All of the operations described in this section must be performed by professionally qualified personnel only.

INSTALLATION ON FLOOR
The space heater may be installed on the floor in a stable position or close to lateral wall fo the room

Warning
At least one of the two side air inlet panel (m) shall be kept open to allow air entering.

The minimum distance from surrounding walls, floor and/or ceiling must always be at least 1 metre.

POWER CONNECTIONS

Warning

  • The power line must be earthed and fitted with a residual current circuit breaker.
  • The power cable must be connected to a panel fitted with a cut-out.

Before switching on the heater and, therefore, before plugging it into the electrical power supply, check that the power supply specifications are the same as those stated on the identification plate.

CONNECTION TO HOT AIR DELIVERY DUCTS
The space heater is set to operate with direct distribution of air. In such case a proper air outlet, chosen by list of available accessories on catalogue, shall be used:

Nevertheless, it can be connected to appropriately sized air distribution channels, if required, with maximum diameter and length as shown in the “TECHNICAL SPECIFICATION TABLE.”

CONNECTION TO EXHAUST DUCT
Exhaust ducts must be in steel and conform to EN 1443. Efficient combustion and trouble-free working of the burner depend on efficient flue draft.

The unit must be connected to the chimney flue in compliance with current legal regulations and in line with the following guidelines:

  • The path of the flue pipe smoke should be as short as possible and should slant upwards (minimum height 1 m);
  • There should be no sharp curves in the pipes, and the diameter of the pipes must never be reduced;
  • there must always be a wind deflector to prevent the entrance of rain and to prevent smoke from being blocked by the wind;
  • flue draft must at least equal the level in the Technical Specifications.
  • every heater must have its own chimney;

The following diagrams show possible flue positions:

FIRST START-UP AND COMBUSTION ADJUSTMENT

Warning

  • The first start-up should always be carried out by a specialised technician checking the correctness of the combustion parameters.
  • The burner settings are pre-set at the factory and may not comply with those required, therefore, the settings need to be checked and, where necessary, corrected.

The adjustment values (burner diesel pressure, combustion head position, air adjustment) for each of the burners approved for these units are indicated in the “TECHNICAL CHARACTERISTICS TABLE”. The probe used to periodically check combustion and flue smoke temperatures is to be inserted as indicated:

Combustion is clean and stable when combustion values are as follows:

  • Bacharach index: 0 (white)
  • CO2: 11 ÷ 12,5 %
  • Oxygen (O2): 4,5 ÷ 6 %
  • COmax: 500 ppm

You may have to change the burner settings due to the fuel used and/or installation conditions (high altitude, air suction pipe with or without Snorkel, etc.) if combustion parameters are not correct. When inspection tests are completed, the hole drilled for the probe must be sealed with a material that is resistant to high temperatures and that ensures the tube remains airtight.

OPERATING INSTRUCTIONS

START
To start the heater:

  • Make sure the switch (a) is set to “0”;
  • Supply electrical power to the space heater by pulling up the disconnecting switch on the electric power panel: the green lamp (b) will light up indicating that power is being supplied to the panel;
  • Turn switch (a) to position H or H+V: the burner will begin the startup and pre-wash cycle, after which the flame will ignite; after the combustion chamber has been heating for a few minutes, the main fan will start up;

Warning

  • The fan runs continuously in H+V mode, even when the desired room temperature has been reached, and the burner turns off.
  • In H mode, the fan only runs when the combustion chamber is sufficiently hot. Therefore, when the desired room temperature has been reached, the burner turns off and the fan keeps running only until the combustion chamber has cooled completely.
  • If the heater does not work during the start cycle or work cycle, consult “TROUBLESHOOTING” to find the cause of the malfunction.

Warning

  • If the burner goes into safety stop (lamp c) push reset button (g) for 3 seconds to restart the heater.
  • If the safety thermostat goes into safety stop (lamp d), push reset button (f) for 3 seconds to restart the heater.
  • NEVER do more than two restarts in a row: unburned fuel can accumulate in the combustion chamber and suddenly flare up at the next restart.

STOP
Stop the heater by turning switch (a) to “0” position or, if the heater is in automatic mode, by setting the room thermostat to a lower temperature: the burner shuts off. The fan keeps working, starting and stopping several times until the combustion chamber has cooled completely.

Warning

  • Never stop the heater by simply turning off the disconnecting switch on the panel.
  • The electrical supply must be disconnected ONLY when the fan has come to a complete stop.

VENTILATION
To run the heater only in continuous ventilation mode, turn switch (a) to the position with the symbol V.

TEMPERATURE CONTROLLER
The heater is equipped with a room thermostat (e) with LCD screen, which displays and controls the room temperature.

The screen displays the measured temperature in [°C]:

To set the desired temperature level:

  • Press the button and then release it: on the screen the initial “SP” and the set temperature alternatively appear .
  • Modify the set temperature pressing buttons and .
  • Press button to confirm the set temperature.

MAINTENANCE

Warning
All of the operations described in this section must be performed by professionally qualified personnel only.

The following procedures must be done at regular intervals to ensure efficient operation of the heater. Make sure you have detached the electrical power line from the heater before starting any work.

Warning
Before doing any maintenance:

  • Stop the heater as indicated in the “STOP” paragraph;
  • Switch off the power supply by means of the cut-off on the electrical panel;
  • Wait until the heater cools.
Procedure Periodic maintenance
Every day Every week

Every year
Check heater| X| | |
Check diesel supply line| X| | |
Clean exterior of heater| X| | |
Clean motor and fan| | X| |
Check electrical connections| | | X|
Check and test burner| | | X|
Check thermostats| | | X|
Clean interior of heater| | | X|
Inspect and clean chamber| | | | X

CHECKING THE HEATER AND THE DIESEL SUPPLY LINE

Perform the following checks:

  • Make sure the heater is not installed where there may be a risk of fire or explosion
  • Make sure that flammable materials are kept a safe distance away
  • If you find diesel leaks:
    • Close the diesel stopcock
    • Find and repair the source of the diesel leak
  • Do not use the heater if any removed panels have not been remounted
  • Make sure the room to be heated is sufficiently ventilated
  • Make sure that the air intake and outlet are completely unobstructed
  • Make sure that the heater is not covered by any sheets or covers
  • Check that the heater is in a fixed and stable position;
  • Make sure the heater is constantly monitored during operation and checked before being started; and checked before being started

CLEANING THE EXTERIOR OF THE HEATER
To ensure efficient operation, clean the following parts:

  • Burner:
    • Remove all external dirt and debris
    • Make sure the air inlet is not obstructed.
  • Pipes, connectors and joints:
    • Clean with a cloth.
  • External body:
    • Clean with a cloth.
  • Air inlet/outlet:
    • Remove all dirt and debris
    • Make sure the air inlet is not obstructed.

Cleaning the motor and the fan
Clean the fan blades and the motor as follows:

  • Remove the fan group fixing screws and then remove the fan group.
  • Clean the motor with compressed air.
  • Clean the fan blades with a hard brush.
  • Reinstall the fan group.

CHECKING THE ELECTRICAL CONNECTIONS
After detaching the power cable, check all electrical connections as follows:

  • Make sure that all connections are complete and tight.
  • If there are traces of dirt or corrosion, clean or replace the connections if necessary.
  • Replace any damaged wires or connectors if necessary.

CHECKING AND TESTING THE BURNER

To reach the burner:

  • Remove the burner fixing screw.
  • Remove the burner and follow the checking and cleaning instructions in the burner manual.
  • Reinstall the burner.
  • Run the procedures described in paragraphs 4.7 and 4.8 to measure combustion parameters and check that combustion is stable and clean.

CHECKING THE THERMOSTATS
Inspect the thermostats as follows:

  • Remove any air outlet connection ducts
  • Find the thermostats fixed to the internal panel of the space heater.
  • Clean with a dry cloth, taking care not to cut or bend the capillary tube.

CLEANING THE INTERIOR OF THE HEATER
For thorough cleaning, the heater can be cleaned and washed inside and outside with water. It is however necessary to ensure that:

  • the electrical cable is disconnected and unplugged from the socket
  • completely close all access panels
  • do not use water jets at a pressure exceeding 70 bar at a distance less than 30 cm
  • completely dry all parts before reconnecting the electrical cable.

CLEANING THE COMBUSTION CHAMBER
To maintain the burner’s high efficiency and prolong its life, the procedure described in this paragraph must be done at least once at the end of the work season or more frequently if there is an excessive build-up of soot. Excessive soot may be caused by poor chimney draught, poor fuel quality, poor regulation of the burner, or more or less frequent alternation of burner starts and stops. Pay attention during operation: pulsations at start may be due to excessive amounts of soot.

To access the heat exchanger (1), take off the rear panel (3), remove the smoke box inspection panel (2), and then remove baffle plates (7). To access the combustion chamber (4) remove the burner (5). Clean with compressed air or, if necessary, with a metal brush to remove any deposited soot and combustion residues.

Warning
After any technical work, always check that the heater works correctly.

TROUBLESHOOTING

In the event of serious anomalies, various safety devices are able to block the machine’s operation and signal the same:

  • on the electrical panel the blocking signal following intervention by safety thermostat L2: the reset button is located inside the burner box.
  • on the burner the blocking signal following intervention by the burner’s flame control box.

Warning
NEVER do more than two restarts in a row: unburned fuel can accumulate in the combustion chamber and suddenly flare up at the next restart.

If the heater is still not working properly, please contact your nearest dealer or authorized Service Centre.

FAULT CAUSE REMEDY
• The heater does not start: lamp  is off

• No power supply

| • Check functioning and position of switch

• Check the mains

• Check power connections

• Check fuse

• The heater does not start: lamp  is on

|

• Switch (a) in wrong position

|

• Select correct position

•   Incorrect functioning of the room thermostat

| • Check that thermostat connection plug is inserted

• Check thermostat electrical connection

• Check thermostat setting and correct it

• Check functioning of thermostat

• The heater works erratically and the burner goes on and off alternately:

|

• Insufficient or no fuel at burner

| • Check condition of pump-motor coupling

• Check for air infiltrations in fuel circuit by checking air-tightness of pipes and filter seal

• Clean nozzle or replace if necessary

•   Burner thermostat has tripped due to overheating

| • Check correct position of air distribution channels and opening of any flaps, openings, etc.

• Remove any foreign bodies trapped in the air ducts or ventilation grilles

• The heater does not work:

the lamp  on the electrical panel is on

|

•   Manual reset safety thermostat has tripped due to excessive overheating of combustion chamber

| • Check that the fan motor starts correctly and is not obstructed

• Check that the fan motor is not burned out or that the motor condenser is not broke

• Check burner calibration

• Check the path and correct discharge of fumes

• Remove any foreign bodies trapped in the air ducts or suction grilles

• Make sure the length of the air supply hoses are not

too long

• The heater does not work::

the lamp  on the burner is steady on

|

•   Burner’s safety equipment has tripped

|

• Refer to the burner manual for diagnosis and causes

• Fan noise or vibrations| • Foreign bodies on fan blades| • Remove foreign bodies
• Insufficienct air circulation| • Eliminate all possible obstacles to proper air flow
• Insufficient heating| • Insufficient burner capacity| • Contact Customer Service

WIRING DIAGRAM

SOVELOR-F30,-F60,-F80-Climate-Solutions-fig- \(16\)

  • M
    FAN MOTOR

  • F
    FAN THERMOSTAT (setting: 30°C)

  • FB
    FUSE

  • ST
    POWER LAMP

  • L2
    LIMIT THERMOSTAT WITH MANUAL RESTART

  • RV
    HEATING-STOP-VENTILATION SWITCH

  • SL
    OVERHEAT THERMOSTATS CONTROL LAMP

  • L1
    BURNER THERMOSTAT (setting: 90°C)

  • TA
    ROOM THERMOSTAT

  • ST
    POWER LAMP

  • BR
    BURNER

WARNING
The warm air generator has been designed to meet the efficiency and performance requirements in force in different regions and countries. It is the responsibility of the installer to check which conditions are required and to ensure that the generator is installed and regulated in accordance with the regulations in force. The chosen setting must be recorded and confirmed in the installation declaration.

DECLARATION OF INSTALLATION AND SETTING

The space heater, Model/Serial number

Fitted with burner

has been set according to specification

Authorised Technical Service / Installer:

Date: Signature:

F 30

TECHNICAL SPECIFICATIONS| ERP 2021
IP protection|  | IP X4D
Type|  | B23P
Fuel|  | DIESEL #2
Max measured heating output| Hs| [kcal/h] [kW] [BTU/h]| 23695

27.55

94782

Net measured heating output

| Hs| [kcal/h] [kW] [BTU/h]| 22304

25,94

89218

Efficiency, h| [%]| 94,1
Consumption| [kg/h]| 2,18
[l / h]| 2,53
Burner|  | ECOFLAM MAX 4 LN
Nozzle|  | DANFOSS 0,55 GPH / 60° H
Diesel pressure| [bar]| 11,5
Combustion head setting| N°.| 28 Kw
Air setting| N°.| 1,7
Seasonal space heating energy efficiency|   [%]|

78,02

Emissions of nitrogen| [mg/kWh]| 81,54
 Air output| [m3/h]| 2700
Available static pressure| [Pa]| 150
Temperature rise| [°C]| 31
Compulsory flue draft| [mbar]| 0,1
Min. service temperature| [°C]| – 20
Max. Service-Temperatur| [°C]| 40
Flue diameter| [mm]| 150
FAN THERMOSTAT| [°C]| 30
BURNER THERMOSTAT| [°C]| 90
Noise level at 1 m| [dBA]| 69
Dimensions, L x W x H| [mm]| 1010 x 530 x 1360
Weight| [kg]| 135
Power supply| [V] / ~ /[Hz]| 230 / 1 / 50
Total power consumption| [W]| 690
Electric current| [A]| 3,2
FUSE| [A]| 16

LUFTEINTRITT AIR INLET – ENTRADA DE AIRE

|  Tube diameter| [mm]| 500
Maximum length| [m]| 6
 AIR OUTLET|  Tube diameter| [mm]| 500
Maximum length| [m]| 25
F 80

TECHNICAL SPECIFICATIONS| ERP 2021
IP protection|  | IP X4D
 Type|  | B23P
Fuel|  | DIESEL #2
 Max measured heating output|

Hs

| [kcal/h] [kW] [BTU/h]| 68695

79,88

274780

Net measured heating output|

Hs

| [kcal/h] [kW] [BTU/h]| 64628

75,15

258513

Efficiency, h| [%]| 94,1
Consumption| [kg/h]| 6,32
[l / h]| 7,35
Burner|  | ECOFLAM MAX P 15 AB LN
Nozzle|  | DELAVAN 1,50 GPH / 60° W
Diesel pressure| Primo stadio – Premier stadestade Erste Leistungsstufe – First stage

Primera etapa – первой ступени

|   [bar]|

11

 Diesel pressure| Secondo stadio – Second stade

Zweite Leistungsstufe – Second stage Segunda etapa – второй ступени

|   [bar]|

13

Combustion head setting| N°.| 90 kW
Air setting| N°.| 2,8
Seasonal space heating energy efficiency|   [%]|

78,19

Emissions of nitrogen oxides| [mg/kWh]| 120,43
Air output| [m3/h]| 7800
Available static pressure| [Pa]| 150
Temperature rise| [°C]| 31
Compulsory flue draft| [mbar]| 0,1
Min. service temperature| [°C]| – 20
Max. service temperature-Temp.| [°C]| 40
Flue diameter| [mm]| 150
FAN THERMOSTAT| [°C]| 30
BURNER THERMOSTAT| [°C]| 90
Noise level at 1 m| [dBA]| 69
Dimensions, L x W x H –| [mm]| 1400 x 640 x 1650
Weight| [kg]| 257
Power supply| [V] / ~ /[Hz]| 230 / 1 / 50
Total power consumption| [W]| 1800
Electric current| [A]| 8,2
FUSE| [A]| 16
AIR INLET|  Tube diameter|   [mm]|

570

Maximum length| [m]| 6
 AIR OUTLET| Tube diameter|   [mm]|

600

Maximum length| [m]| 25
ErP 2016/2281/UE

Information requirements for warm air heaters


Model|

F 30

Warm air heaters|

C2

Brennstoffart Type of fuel| Liquido – Liquide

Flüssig – Liquid Líquido

Rated heating capacity|

Prated,h

|   [kW]|

27,55

Minimum capacity|

Pmin

|   [kW]|

27,55

Useful efficiency at rated heating capacity|

ηnom

|   [%]|

94,13

Useful efficiency at minimum capacity|

ηpl

|   [%]|

94,1

Electric power consumption at rated heating capacity

|

elmax

|   [kW]|

0,125

Electric power consumption at minimal capacity|

elmin

|   [kW]|

0,125

Electric power consumption in standby mode|

elmsb

|   [kW]|

0,005

Envelope loss factor|

Fenv

|   [%]|

0,0%

Ignition burner power consumption|

Pign

|   [kW]|

0,1

Emissions of nitrogen oxides|

NOX

| mg/kWh (GCV)|

81,54

Seasonal space heating energy efficiency|

ηs,h

|   [%]|

78,02

F 60

TECHNICAL SPECIFICATIONS| ERP 2021
IP protection|  | IP X4D
Type|  | B23P
Fuel|  | DIESEL #2
Max measured heating output|

Hs

| [kcal/h] [kW] [BTU/h]| 51195

59,53

204780

 Net measured heating output|

Hs

| [kcal/h] [kW] [BTU/h]| 47908

55,71

191633

Efficiency, h| [%]| 93,6
Consumption| [kg/h]| 4,71
[l / h]| 5,48
Burner|  | ECOFLAM MAX 8 LN
Nozzle|  | DANFOSS 1,10 GPH / 60° H
Diesel pressure| [bar]| 13
Combustion head setting| N°.| 58 Kw
Air setting| N°.| 3,6
Seasonal space heating energy efficiency|   [%]|

78,12

Emissions of nitrogen oxides|   [mg/kWh]|

64,85

Air output| [m3/h]| 6000
Available static pressure| [Pa]| 150
Temperature rise| [°C]| 37,5
Compulsory flue draft| [mbar]| 0,1
Min. service temperature| [°C]| – 20
Max. service temperature-Temp.| [°C]| 40
Flue diameter| [mm]| 150
FAN THERMOSTAT| [°C]| 30
BURNER THERMOSTAT| [°C]| 90
Noise level at 1 m| [dBA]| 69
Dimensions, L x W x HВ| [mm]| 1045 x 600 x 1045
Weight| [kg]| 185
Power supply| [V] / ~ /[Hz]| 230 / 1 / 50
Total power consumption| [W]| 1360
Electric current| [A]| 6,0
FUSE| [A]| 16
LUFTEINTRITT AIR INLET –| Tube diameter

|   [mm]|

500

Maximum length|   [m]|

6

 AIR OUTLET|  Tube diameter|   [mm]|

500

Maximum length|   [m]|

25

Information requirements for warm air heaters

Model|

F 60

Warm air heaters|

C2

Brennstoffart Type of fuel| Liquid
Rated heating capacity|

Prated,h

|   [kW]|

59,53

Minimum capacity|

Pmin

|   [kW]|

59,53

Useful efficiency at rated heating capacity| ηnom| [%]| 93,58
Useful efficiency at minimum capacity| ηpl|   [%]|

93,58

Electric power consumption at rated heating capacity| elmax| [kW]| 0,460
Electric power consumption at minimal capacity| elmin| [kW]| 0,460
Electric power consumption in standby mode| elmsb| [kW]| 0,005
Envelope loss factor| Fenv| [%]| 0,0%
Ignition burner power consumption| Pign| [kW]| 0,5
Emissions of nitrogen oxides

| NOX| mg/kWh (GCV)| 64,85
Seasonal space heating energy efficiency| ηs,h| [%]| 78,12
ErP 2016/2281/UE

Information requirements for warm air heaters


Model|

F 80

Warm air heaters| C2
Type of fuel| Liquid
Rated heating capacity|

Prated,h

|   [kW]|

79,88

Minimum capacity|

Pmin

|   [kW]|

79,88

Useful efficiency at rated heating capacity|

ηnom

|   [%]|

94,08

Useful efficiency at minimum capacity|

ηpl

|   [%]|

94,08

Electric power consumption at rated heating capacity|

elmax

|   [kW]|

0,380

Electric power consumption at minimal capacity|

elmin

|

[kW]|

0,380

Electric power consumption in standby mode|

elmsb

|   [kW]|

0,005

Envelope loss factor|

Fenv

|   [%]|

0,0

Ignition burner power consumption|

Pign

|   [kW]|

0,4

Emissions of nitrogen oxides|

NOX

| mg/kWh (GCV)|

120,43

Seasonal space heating energy efficiency|

ηs,h

|   [%]|

78,19

F 30 (ERP 2021)

SOVELOR-F30,-F60,-F80-Climate-Solutions-fig- \(20\)

SOVELOR-F30,-F60,-F80-Climate-Solutions-fig- \(21\)

PL 09/21| From S/N|
---|---|---
 |
POS| P/N| LEGENDA| DESCRIPTION|
1| G05220-7043| –| Panel|
2| G05221-7035| SX| Panel|
3| G05208| SX| Isolation|
4| P30169| –| Inlet grill|
5| G00525-1| –| El. control box|
6| P50156| –| Frame|
7| G05222-7043| –| Panel|
8| C30396-1| –| Stirrup|
9| G05227-7043| –| Panel|
10| M20406| –| Pin|
11| M20418| –| Lock|
12| G05223-7043| –| Panel|
13| G05224-7043| –| Panel|
14| C30301| Ø18 mm| Cable protection|
15| G05200-7043| –| Panel|
16| G05225-7043| –| Panel|
17| G05226| –| Panel|
18| T20385| DANFOSS

0,55 GPH 60° H

| Nozzle|
19| 072B126| ECOFLAM MAX 4 LN| Oil burner|
20| G00524| –| El. control box|
21| E30491| L = 1,67 m| Power cord|
22| E30422| L = 3 m| Power cord|
23| G00526| –| Themostat control box|
24| G05228-7043| –| Panel|
25| G05229| –| Isolation|
26| G05230-7035| –| Panel|
27| G05189-7035| –| Chimney panel|
28| G05190-7035| –| Panel|
29| G05206| –| Combustion chamber|
30| G05231-7035| DX| Panel|
31| G05212| DX| Isolation|
32| E50798-2| –| Probe|
33| G05232-7043| DX| Panel|
34| G05233-7035| –| Base|
35| P50154| 80 l| Fuel tank|
36| P50154-3| C35| Level control|
37| P50154-2| –| Diesel filter|
38| P50154-1| –| Cap|
39| I25028| 1/2″M – 1/2″M – L=60| Iron fitting|
40| I25029| 1/2″ F| Iron cap|
41| T10705| CBM12/12| Fan|
42| T10705-20| CBM 10-8 245W – 6PC| Motor|
43| T10705-10| 10 µF| Capacitor|
44| I20104| 1/4″M – 1/4″M| Iron fitting
---|---|---|---
45| I31131| M5| Brass hose connection
46| I40306| Ø8×6 (L=1 m)| Rilsan pipe
47| G05237| –| Support plate
48| I31143| NBR| Seal
49| I30522| 1/4″F – 1/4″F – L=22| Fitting
50| I40344| L = 315mm – 1/4″ F| Flex diesel pipe
51| C30729| Ø12,5 – 14,5/6

CLIC120

| Clip
52| I31022| –| Filter
53| I20613| 1/4″F – 1/4″M| Fitting
54| I20301| 1/4″MF / 90°| Fitting
55| T20201| 1/4″FF| Diesel filter
56| T20234| GIULIANI ANELLO| Filter seal kit
57| T20206| –| Filter cartridge
58| T20212| –| Filter container
59| G05218| –| Turbulence-generating grid
60| T10612| –| Seal
61| G05219| –| Inspection panel
62| E20719-12| –| El. components box
63| E20933| PG 9| Cable fastener
64| E20956| PG 9| Cable fastener nut
65| E50747-10| TY95 – 20/60 °C| Fan Thermostat
66| E50748-10| TY95 30/90 °C| Burner thermostat
67| E50749| TY95H 120 °C| Safety thermostat
68| E50750| –| Safety thermostat plastic profile
69| G05234| –| Support plate
70| G04305| –| Support bracket
71| E20725-06| –| El. components box
72| E20312| 7P| Plug
73| E20959| PG 13,5| Cable fastener
74| E20960| PG 13,5| Cable fastener nut
75| E20508| 6 x 32| Fuse holder
76| E10323| 6×30 – 16A – T| Fuse
77| E20301| 10 mm2 – 12 pin| Terminal board
78| E20319| –| Ground terminal board
79| E10451| AS09-30-10| Contactor
80| E20337| WAGO – 5 pin| Terminal board
81| G05204| –| Support plate
82| G04387-9005| –| Stirrup
83| E11033| 230V| Lamp
84| E11036| 250V| Lamp
85| E10141| I – 0 – II – III| Switch
86| E50798| E31| Thermostat
---|---|---|---
87| E50798-1| –| Seal
88| G05235| –| Electrical panel box
89| E20928| PG 7| Cable fastener nut
90| E20927| PG 7| Cable fastener
91| E20302| 6 mm2 – 12 pin| Terminal board
92| M20615| –| Terminal board to rivet
93| G05236-7035| –| El. control box panel

F 60 (ERP 2021)

SOVELOR-F30,-F60,-F80-Climate-Solutions-fig- \(22\)

SOVELOR-F30,-F60,-F80-Climate-Solutions-fig- \(23\)

PL 09/21| From S/N|
---|---|---
 |
POS| P/N| LEGENDA| DESCRIPTION|
1| G05238-7043| SX| Panel|
2| G05239-7035| SX| Panel|
3| G05185| SX| Isolation|
4| P30191| –| Outlet grill|
5| G00525-1| –| El. control box|
6| P50156| –| Frame|
7| G05240-7043| –| Panel|
8| C30396-1| –| Stirrup|
9| G05241-7043| –| Panel|
10| M20406| –| Pin|
11| M20418| –| Lock|
12| G05242-7043| –| Panel|
13| G05243-7043| –| Panel|
14| C30301| Ø18 mm| Cable protection|
15| G05200-7043| –| Panel|
16| G05244-7043| –| Panel|
17| G05245| –| Panel|
18| T20387| DANFOSS

1,10 GPH 60° H

| Nozzle|
19| 072B127| ECOFLAM MAX 8 LN| Oil burner|
20| G00524| –| El. control box|
21| E30491| L = 1,67 m| Power cord|
22| E30422| L = 3 m| Power cord|
23| G00526| –| Themostat control box|
24| G05246-7043| –| Panel|
25| G05247| –| Isolation|
26| G05248-7035| –| Panel|
27| G05189-7035| –| Chimney panel|
28| G05190-7035| –| Panel|
29| G05183| –| Combustion chamber|
30| G05249-7035| DX| Panel|
31| G05191| DX| Isolation|
32| E50798-2| –| Probe|
33| G05250-7043| DX| Panel|
34| G05251-7035| –| Base|
35| P50155| 110 l| Fuel tank|
36| P50154-3| C35| Level control|
37| P50154-2| –| Diesel filter|
38| P50154-1| –| Cap|
39| I25028| 1/2″M – 1/2″M – L=60| Iron fitting|
40| I25029| 1/2″ F| Iron cap|
41| T10706| CBM 12-9| Fan|
42| T10706-20| CBM 12-9 736W. 6PC| Motor|
43| T10706-10| 20 µF| Capacitor|
44| I20104| 1/4″M – 1/4″M| Iron fitting
---|---|---|---
45| I31131| M5| Brass hose connection
46| I40306| Ø8×6 (L=1 m)| Rilsan pipe
47| G05237| –| Support plate
48| I31143| NBR| Seal
49| I30522| 1/4″F – 1/4″F – L=22| Fitting
50| I40344| L = 315mm – 1/4″ F| Flex diesel pipe
51| C30729| Ø12,5 – 14,5/6

CLIC120

| Clip
52| I31022| –| Filter
53| I20613| 1/4″F – 1/4″M| Fitting
54| I20301| 1/4″MF / 90°| Fitting
55| T20201| 1/4″FF| Diesel filter
56| T20234| GIULIANI ANELLO| Filter seal kit
57| T20206| –| Filter cartridge
58| T20212| –| Filter container
59| G05202| –| Turbulence-generating grid
60| T10806| –| Seal
61| G05203| –| Inspection panel
62| E20719-12| –| El. components box
63| E20933| PG 9| Cable fastener
64| E20956| PG 9| Cable fastener nut
66| E50747-10| TY95 – 20/60 °C| Fan Thermostat
65| E50748-10| TY95 30/90 °C| Burner thermostat
67| E50749| TY95H 120 °C| Safety thermostat
68| E50750| –| Safety thermostat plastic profile
69| G05234| –| Support plate
70| G04305| –| Support bracket
71| E20725-06| –| El. components box
72| E20312| 7P| Plug
73| E20959| PG 13,5| Cable fastener
74| E20960| PG 13,5| Cable fastener nut
75| E20508| 6 x 32| Fuse holder
76| E10323| 6×30 – 16A – T| Fuse
77| E20301| 10 mm2 – 12 pin| Terminal board
78| E20319| –| Ground terminal board
79| E10451| AS09-30-10| Contactor
80| E20337| WAGO – 5 pin| Terminal board
81| G05204| –| Support plate
82| G04387-9005| –| Stirrup
83| E11033| 230V| Lamp
84| E11036| 250V| Lamp
85| E10141| I – 0 – II – III| Switch
86| E50798| E31| Thermostat
---|---|---|---
87| E50798-1| –| Seal
88| G05235| –| Electrical panel box
89| E20928| PG 7| Cable fastener nut
90| E20927| PG 7| Cable fastener
91| E20302| 6 mm2 – 12 pin| Terminal board
92| M20615| –| Terminal board to rivet
93| G05236-7035| –| El. control box panel

F 80 (ERP 2021)

SOVELOR-F30,-F60,-F80-Climate-Solutions-fig- \(24\)

SOVELOR-F30,-F60,-F80-Climate-Solutions-fig- \(25\)

PL 09/21| From S/N|
---|---|---
 |
POS| P/N| LEGENDA| DESCRIPTION|
1| G05252-7043| SX| Panel|
2| G05253-7035| SX| Panel|
3| G05185| SX| Isolation|
4| P30129| –| Inlet grill|
5| G00525-1| –| El. control box|
6| P50156| –| Frame|
7| G05255-7043| –| Panel|
8| C30396-1| –| Stirrup|
9| G05256-7043| –| Panel|
10| M20406| –| Pin|
11| M20418| –| Lock|
12| G05257-7043| –| Panel|
13| G05258-7043| –| Panel|
14| C30301| Ø18 mm| Cable protection|
15| G05200-7043| –| Panel|
16| G05259-7043| –| Panel|
17| G05260| –| Panel|
18| T20389| DELAVAN

1,50 GPH 60° W

| Nozzle|
19| 072B128| ECOFLAM

MAX P 15 AB LN

| Oil burner|
20| G00524| –| El. control box|
21| E30492| L = 2,17 m| Power cord|
22| E30422| L = 3 m| Power cord|
23| G00526| –| Themostat control box|
24| G05261-7043| –| Panel|
25| G05262| –| Isolation|
26| G05263-7035| –| Panel|
27| G05189-7035| –| Chimney panel|
28| G05190-7035| –| Panel|
29| G05264| –| Combustion chamber|
30| G05265-7035| DX| Panel|
31| G05266| –| Isolation|
32| E50798-2| –| Probe|
33| G05267-7043| DX| Panel|
34| G05268-7035| –| Base|
35| P50155| 110 l| Fuel tank|
36| P50154-3| C35| Level control|
37| P50154-2| –| Diesel filter|
38| P50154-1| –| Cap|
39| I25028| 1/2″M – 1/2″M – L=60| Iron fitting|
40| I25029| 1/2″ F| Iron cap|
41| T10701| CBM 12/12| Fan|
42| T10701-20| CBM 12-12 736W. 6PC| Motor|
43| T10701-10| 20 µF| Capacitor|
44| I20104| 1/4″M – 1/4″M| Iron fitting
---|---|---|---
45| I31131| M5| Brass hose connection
46| I40306| Ø8×6 (L=1 m)| Rilsan pipe
47| G05237| –| Support plate
48| I31143| NBR| Seal
49| I30522| 1/4″F – 1/4″F – L=22| Fitting
50| I40344| L = 315mm – 1/4″ F| Flex diesel pipe
51| C30729| Ø12,5 – 14,5/6

CLIC120

| Clip
52| I31022| –| Filter
53| I20613| 1/4″F – 1/4″M| Fitting
54| I20301| 1/4″MF / 90°| Fitting
55| T20201| 1/4″FF| Diesel filter
56| T20234| GIULIANI ANELLO| Filter seal kit
57| T20206| –| Filter cartridge
58| T20212| –| Filter container
59| G04333| –| Turbulence-generating grid
60| T10687| 444x251x5| Insulating gasket
61| G04321| –| Panel
62| G04320| –| Inspection panel
63| T10804| D170 x D120| Insulating gasket
64| G04322| Ø 150| Chimney fitting
65| G05269-7043| –| Stirrup
66| T10691| D60 x D25| Insulating gasket
67| G05270| –| Panel
68| E20719-12| –| El. components box
69| E20933| PG 9| Cable fastener
70| E20956| PG 9| Cable fastener nut
72| E50747-10| TY95 – 20/60 °C| Fan Thermostat
71| E50748-10| TY95 30/90 °C| Burner thermostat
73| E50749| TY95H 120 °C| Safety thermostat
74| E50750| –| Safety thermostat plastic profile
75| G05234| –| Support plate
76| G04305| –| Support bracket
77| E20725-06| –| El. components box
78| E20312| 7P| Plug
79| E20959| PG 13,5| Cable fastener
80| E20960| PG 13,5| Cable fastener nut
81| E20508| 6 x 32| Fuse holder
82| E10323| 6×30 – 16A – T| Fuse
83| E20301| 10 mm2 – 12 pin| Terminal board
84| E20319| –| Ground terminal board
85| E10451| AS09-30-10| Contactor
86| E20337| WAGO – 5 pin| Terminal board
---|---|---|---
87| G05204| –| Support plate
88| G04387-9005| –| Stirrup
89| E11033| 230V| Lamp
90| E11036| 250V| Lamp
91| E10141| I – 0 – II – III| Switch
92| E50798| E31| Thermostat
93| E50798-1| –| Seal
94| G05235| –| Electrical panel box
95| E20928| PG 7| Cable fastener nut
96| E20927| PG 7| Cable fastener
97| E20302| 6 mm2 – 12 pin| Terminal board
98| M20615| –| Terminal board to rivet
99| G05236-7035| –| El. control box panel

Dantherm LLC
ul. Transportnaya 22/2,
142802, STUPINO, Moscow region, RUSSIA