SOVELOR Ceiling Heater AER25 3N400V Installation Guide

June 3, 2024
SOVELOR

SOVELOR Ceiling Heater AER25 3N400V

SOVELOR Ceiling Heater AER25 3N400V

INSTRUCTIONS OF ASSEMBLY FOR CEILING HEATER AER25 3N400V

Use

Heater designed to be used as a fixed unit, mounted on the ceiling or in high places, recirculating to the area below. For correct operation the unit should be operated with the remote electronic control model C19500.

Installation

  • The air heater must be fixed with a welded mesh chain, it has 4 DIN580 eyebolts.
  • Once fixed with the chains, the air heater must be levelled for correct operation [Fig.2]. Installation of the air-heater must be carried out in accordance with national  authority regulations.
    ![SOVELOR Ceiling Heater AER25 3N400V

Installation](https://manuals.plus/wp-content/uploads/2022/12/SOVELOR- Ceiling-Heater-AER25-3N400V-Installation-Guide-4.png)

  • Check that the supply voltage is the same as the one specified on the characteristics label. Do not install the air-heater in places where there is risk of fire, explosion, etc. Important: Do not prevent free circulation of air by objects totally or partially covering the air-heater, as there is risk of over-heating.

  • Leave an obstacle-free area around the air-heater, for air to circulate freely [Fig.2].

  • Try to ensure that the air heater heats the air uniformly in the required area

  • Direct the air outlet towards a free space [Fig.1].

  • Do not install the air-heater under or near an electrical  socket

  • The supply lead cable must not be left in the air-outlet or in contact with hot areas of the air heater

  • The air-heater is supplied from the factory ready for connection to a three-phase main supply with: Neutral and earth 3N~400V. Important: the three-phase main supply must be protected at source against over-intensities and shortcircuits.Supply lead: SOVELOR recommends flexible lead of minimum quality type H-07- RN-F.Connecting air-heater: Remove the cover of the connections [Fig.3], leaving the wires accessible.
    ![SOVELOR Ceiling Heater AER25 3N400V

Installation](https://manuals.plus/wp-content/uploads/2022/12/SOVELOR- Ceiling-Heater-AER25-3N400V-Installation-Guide-6.png)

  • Connect the power and control cables through the corresponding wire feed [Fig.4]. Power: Connect the supply lead to the block as follows: 3 power phases R, S, T to the block terminals 1 neutral to block terminal N. 1 earth wire, to block terminal see connection diagram and [Fig.4]. Important: check that the electrical connection screws are properly tightened, with a 2Nm minimum torque

Command: Connect the control ACC1801 to the air-heater.
Interconnect terminals 1, 2, 3, 4, 5 and 6 of the air-heater with the same numbered terminals of the ACC1801 control. Cable 6×1 mm2. See diagram and [Fig.4]-
Safety: The air-heaters are fitted with a temperature limiter which disconnects if over-heating occurs, reconnecting the air heater when it cools down. If this cycle repeats itself, disconnect the air-heater from the mains and find out the reason for the failure (motor blockage, air-flow obstruction), solve the problem and reconnect the unit. 1-minute timed halt of the fan, to dispel the heat from the elements, preventing overheating when the unit is turned off. This operation is carried out automatically, the timer only operating with the heating steps.
Motor: With the voltage on, turn on the ventilation stage and make sure the blades turn correctly.

COMMAND INSTRUCTIONS ACC1801

Functioning: The remote has the following buttons:

  • Fan
  • • Power step 1
  •  • • Total power
  • [+ -] Temperature or time modification Unit
    stopped: If the unit is connected to the main, without working, only two lines are shown on the display, indicating that the unit is ready to work.
  1. Modification set temperature: Press button + to  increase temperature and key –to lower it. The number flashes for 10 seconds and is automatically entered. Temperature range +5ºC +35ºC

  2. Fan.
    Press the fan button and the fan will come on without heating. By pressing the same button for a few seconds, we activate the timer, being able to select the time it is on from 1 to 9 hours. With button + to increase time and button – to reduce it.
    The number flashes for 10 seconds and is automatically entered.

  3. Cancellation of timer. When the unit is switched off the timer is set to 0 hours. In the following operations if no option timer is selected then remains to 0 hours, otherwise is displayed the last timer time chosen.

  4. 1st power step.
    ● Press 1st power step button •.
    ● For temperature and time selection, follow the steps indicated above. Stoppage is timed for 1 minute to dispel heat from the elements.

  5. 2nd speed total power
    ● Press 2nd step power button ••.
    ● For temperature and time
    selection, follow the steps indicated above. Stoppage is timed for 1 minute to dispel heat from the elements.

  6. Modification system stop/start of ventilation. – Press button of ventilation nr.2, during 3 seconds, then it will appear display’s timer. Push again button nr.2 till it displays nr. 0 or nr.1  Modify ventilation option bymeans of buttons +/- Option 0, stop heaters and fan. Option 1, stop only heaters. The operation remains void after 5 seconds. The Factory configuration is option 1.
    SWITCH OFF THE EQUIPMENT: To press the key that is on.

Maintenance: Disconnect the air-heater from the mains before any maintenance operation. We recommend periodic cleaning of the 2 grids and removing dust and dirt deposits, as often as necessary depending on the working atmosphere. Check that the electrical terminals are properly tightened.
Remarks: The temperature probe is located at the back of the air-heater. When the unit is left on for a long time, the heat generated by it can modify the temperature around the heater by about ~3ºC in relation to the room temperature. Important: When it is time for the air-heater to be finally turned off, this must be done from the control bottoms. Once the fan has stopped, the unit can be turned off.
Guarantee: SOVELOR guarantees its products against all defects in manufacture or material for a period of two years from the date of supply. The guarantee is limited to the replacement or repair, at our criteria, of the defective part, provided the product has been used pursuant to specifications. The use of the product in applications or under conditions other than those stated as suitable shall always be at the user’s own risk, voiding the guarantee.

WIRING DIAGRAMS

![SOVELOR Ceiling Heater AER25 3N400V

Wiring Diagrams](https://manuals.plus/wp-content/uploads/2022/12/SOVELOR- Ceiling-Heater-AER25-3N400V-Installation-Guide-8.png)

TYPE CODE V kW FREQUENCY m³/h r.p.m MOTOR dB Kg
AER25 3N400   50/60Hz 2600 1450 56 38
10373 24
 

AIR-HEATER MODEL

24 kW

Do not dispose of as domestic refuse, electrical product defined in the applicable Directive. For its proper handing as refuse, follow the selective collection mechanisms corresponding to your town.