RAB T5H0-12-24G-8XX-SD-BYP LED T5 Tube Series or Double Ended Bypass Instructions

June 12, 2024
RAB

RAB T5H0-12-24G-8XX-SD-BYP LED T5 Tube Series or Double Ended Bypass

IMPORTANT

READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
RAB LED tubes must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.

WARNING:

  • Risk of fire or electric shock. LED Retrofit Kit installation requires knowledge of luminaire electrical systems. If not qualified, do not attempt installation. Contact a qualified electrician.
  • Risk of fire or electric shock. Install this kit only in the luminaires that have the construction features and dimensions shown in the photographs and/or drawings and where the input rating of the retrofit kit does not exceed the input rating of the luminaire.
  • To prevent wiring damage or abrasion, do not expose wiring to the edges of sheet metal or other sharp objects.
  • Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.
  • Installers should not disconnect existing wires from lamp holder terminals to make new connections at lamp holder terminals. Instead, installers should cut existing lamp holder leads away from the lamp holder and make new electrical connections to lamp holder lead wires by employing applicable connectors.
  • This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1 )this device may mt cause harmful interference, and (2)this device must accept any interference received, including interference that may cause undesired operation.
  • WARNING: To avoid potential fire or shock hazards, do not use this retrofit kit in luminaires employing shunted bi-pin lamp holders. Note: Shunted lamp holders are found only in f1uorescent luminaires with Instant-Start ballasts. Instant-start ballasts can be identified by the words “Instant Start” or “I.S.” marked on the ballast. This designation may be in the form of a statement pertaining to the ballast itself or may be combined with the marking for the lamps with which the ballast is intended to be used, for example, F40T12/IS. For more information, contact the LED luminaire retrofit kit manufacturer.
  • Type B LAMP – intended for operation in luminaires with traditional f1uorescent-type lamp holders wired directly to the branch circuit. This includes both factory-wired luminaries as well as those converted for this purpose under a retrofit program.

SAFETY PRECAUTIONS

  • The product should be installed by a qualified electrician.
  • Switch off the power supply before commencing work, and make sure the correct connection is before powering on.
  • THIS RETROFIT KIT IS ACCEPTED AS A COMPONENT OF A LUMINAIRE WHERE THE SUITABILITY OF THE COMBINATION SHALL BE DETERMINED BY AUTHORITIES HAVING JURISDICTION.
  • THERE ARE TUBE, OPERATION INSTRUCTIONS, AND THE FIELD APPLIED DOUBLE-ENDED OR SINGLE-ENDED APPLICATION LABEL IN THIS RETROFIT KIT.
  • Only use the control provided with or specified by these instructions to control this lamp. This lamp will not operate properly when connected to a standard (incandescent) dimmer or dimming control. This lamp can be dimmed by a specified dimmer, please consult with the manufacturer for detailed dimmer information.

The below ballast wiring represents a typical configuration. The actual ballast wiring varies according to the ballast model. The socket should be non-shunted.

Single-ended Wiring Instruction

Retrofit luminaire with 1 lamp

RAB-T5H0-12-24G-8XX-SD-BYP-LED-T5-Tube-Series-or-Double-Ended-Bypass-fig-
\(1\)

Retrofit luminaire with 2 lamps

RAB-T5H0-12-24G-8XX-SD-BYP-LED-T5-Tube-Series-or-Double-Ended-Bypass-fig-
\(2\)

Retrofit luminaire with 4 lamps

RAB-T5H0-12-24G-8XX-SD-BYP-LED-T5-Tube-Series-or-Double-Ended-Bypass-fig-
\(3\)

RAB-T5H0-12-24G-8XX-SD-BYP-LED-T5-Tube-Series-or-Double-Ended-Bypass-fig-
\(4\)

The below ballast wiring represents a typical configuration. The actual ballast wiring varies according to the ballast model. It is not needed to change the socket (if in good condition} to operate double-ended lamps, regardless of the type of socket. Please make sure one side of the fixture is connected to Live (L) and the other side to Neutral (N}.

Double-ended Wiring Instruction

Retrofit luminaire with 1 lamp

Instant Start

Program Start or Rapid Start

Retrofit luminaire with 2 lamps

Instant Start

RAB-T5H0-12-24G-8XX-SD-BYP-LED-T5-Tube-Series-or-Double-Ended-Bypass-fig-
\(7\)

Program Start or Rapid Start

RAB-T5H0-12-24G-8XX-SD-BYP-LED-T5-Tube-Series-or-Double-Ended-Bypass-fig-
\(8\)

Retrofit luminaire with 4 lamp

Instant Start

RAB-T5H0-12-24G-8XX-SD-BYP-LED-T5-Tube-Series-or-Double-Ended-Bypass-fig-
\(9\)

Program Start or Rapid Start

RAB-T5H0-12-24G-8XX-SD-BYP-LED-T5-Tube-Series-or-Double-Ended-Bypass-fig-
\(10\)

The units covered by this report were intended to retrofit surface mount, Type IC or non-IC recessed mount Listed fluorescent luminaires that use a maximum of four or six tubular lamps. The minimum lamp compartment dimensions are tabulated below:

RAB-T5H0-12-24G-8XX-SD-BYP-LED-T5-Tube-Series-or-Double-Ended-Bypass-fig-
\(11\)

RAB Lighting is committed to creating high-quality, affordable, well-designed, and energy-efficient LED lighting and controls that make it easy for electricians to install and end users to save energy. We’d love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: marketing@rablighting.com.

RAB WARRANTY

RAB’s warranty is subject to all terms and conditions found at rablighting.com/warranty.

Easy Answers

rablighting.com. Visit our website for product info.

Tech Help Line
Call our experts: 888 722-1000

e-mail
Answered promptly – sales@rablighting.com.

Free Lighting Layouts
Answered online or by request

RAB
© 2023 RAB LIGHTING Inc.
Cranbury, New Jersey 08512 USA.

T5SDBYP-IN-0623

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals