Rubine RCF-WR603-2101-BK Ceiling Fan User Manual

October 31, 2023
Rubine

Rubine logo REDEFINE THE WAY OF LIFE Rubine RCF WR603 2101 BK Ceiling
FanUSER MANUAL
MODEL RCF-WR603-2101-BK/WH

RCF-WR603-2101-BK Ceiling Fan

CEILING FAN
SUPPLIED PARTS

NO PARTS QUANTITY
1 HANGING TUBE ASSEMBLY x 4
2 FAN MOTOR ASSEMBLY x 1
3 TOP CANOPY x 1
4 COUPLING COVER x 1
5 FAN REGULATOR x 1
6 FAN BLADES x 3

Rubine RCF WR603 2101 BK Ceiling Fan - PARTS

Caution
(a) This appliance must be earthed.
(b) Do not use any other hanging tube except provided by Rubine. This is to ensure good performance and extra protection.
(c) To reduce the risk of injury to person, install fan at least 2.5m (8.3ft) above the ground and 1 meter from the nearest wall.
(d) The replacement of parts of the safety suspension system shall be performed by the manufacturer, its service agent or suitably qualified persons.
(e) The double pole single throw switch must have a contact separation of at least 3mm. It must be incorporated in the fixed wiring.
(f) Safety wire must be able to withstand 10 times the weight of fan body.
(g) Disconnect power supply before dismantling any part for cleaning.
(h) Do not attempt to repair fan. Always return fan to our authorised service agent for repair.
(i) Do not use in hot or wet environment or near to flammable materials.
(j) The wires in this main leads are coloured in accordance with the following code:
(k) If the supply cord is damaged, it must be replaced by the manufacturer,its service agent or similarly qualified persons in order to avoid a hazard.
(l) This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities,or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
WARNING
Do not use these appliance in high temperature and high humidity.
(m) Primary suspension system length more than 280mm of non-standard hanging tube shall be supplied by the same manufacturer, with similar material, complete with safety wire rope, marking and installation instruction.
(n) If unusual oscillating movement is observed, immediately stop using the ceiling fan and contact the manufacturer, its service agent or suitably qualified persons.

Cares and maintenance

(a) Keep the fan clean.
(b) Use it in dry place.
(c) Do not bend the blades when installing & maintaining.
(d) Wipe away dirt with clean soft cloth, soap & water to clean the fan.Wipe until dry. Do not use solvents such as gasoline or petroleum.
(e) It is recommended to examine the fan suspension system for wear & tear of the bolt & rod at least once every year.

Safety precations

To avoid the possibility of causing injury to users or damage to properties, please follow all the explanations written below.

WARNING| A state that may be caused by the mishandling of products, which, if not avoided, may lead to the possibility of death or serious injury of users.
---|---
CAUTION| This sign warns of injury or damage to property.
| This symbol denotes an action that is COMPULSORY.
| This symbol denotes an action that is PROHIBITED.

Warning

(a) Ceiling Fan must be mounted above 2.5m from the floor and lm from the wall to the Blade.
Avoid fixing inside the dome ceiling.
Rubine RCF WR603 2101 BK Ceiling Fan - dome ceiling(b) Ensure Down Rod has been fully tighten to Motor Shaft. (Bolt tightening torque is 800∼1000 N•cm)
Can cause injury if ceiling fan drops.
(c) Snap Pin must fix into Bolt as shown. Can cause injury if Ceiling Fan drops.

Parts identification

Rubine RCF WR603 2101 BK Ceiling Fan - Parts
identification

Specifications

Blade Size| Voltage| Power| Ma x Speed (rpm)| Net Weight
---|---|---|---|---
60″| 220-240V ∼ 50Hz| 75W| 303±10%| 5.4kg

Specification subject to change without prior notice.

Assembly Instructions

(a) Connect brown and blue wires from downrod to the terminal block marked ‘L’ and ‘N’ respectively. Assemble fan blade (3 pes) to motor with the provided screws.
Install fan unit with rubber wheel to ceiling hook and tighten with bolt & nut and snap pin.
Connect fan wires to the power supply point. Rubine RCF WR603 2101 BK
Ceiling Fan - AssemblySafety wire installation
(b) Take out the Bolt & Hex Nut assembly from the part set and attach assembled ceiling fan to the Ceiling Hook and adjust the bolt parallel to the Bracket hole and lock tightly. Rubine RCF WR603 2101 BK Ceiling Fan - safty
wire(c) Ensure that the safety wire is properly and correctly inserted through the hole on the motor shaft and down rod as shown in Fig.
(d) Loop the safety wire across the ceiling hook, then tighten the screw at down rod and make sure the screw is securely fixed.

WARNING

| The safety wire must be installed securely.
Can cause injury if ceiling fan drops.

Rubine RCF WR603 2101 BK Ceiling Fan - Screw(e) Push up the top canopy to cover ceiling hook, then tighten canopy screw as shown.Rubine RCF WR603 2101 BK Ceiling Fan - ceiling
hook(f) Make sure the distance of the lower canopy must be installed with a spacing of Smm from the motor as show below. Rubine RCF WR603 2101 BK Ceiling Fan - Bottom CanopyInstall blade to motor unit
(g) Remove blade bolt (6 pieces) of the motor unit. Install the fan blades properly, make sure the underlay is also fitted between the blade and the motor unit and tighten the bolt. Rubine RCF WR603 2101 BK Ceiling Fan -
Remove blade bolt(h) Do not fix the blade at the position as shown in the figure. Can cause no air flow. Can cause injury if blades drop. Rubine RCF WR603 2101 BK Ceiling Fan - air
flow

WARNING

| Do not fix at this position.
| Lock the screw tightly.

How To Install Regulator

This must be a double pole switch with minimum 3mm contact gap in the fixed installation circuit.

  1. Remove the cover set of regulator using screwdriver.
  2. Fix the regulator base on the wall.Rubine RCF WR603 2101 BK Ceiling Fan - Circuit Diagram
  3. Reassemble the regulator cover above

Power supply wire connected to the terminal should be equipped with splice.Rubine RCF WR603 2101 BK Ceiling Fan - Power
supply

Wiring Diagram

Rubine RCF WR603 2101 BK Ceiling Fan - Wiring DiagramEnsure that the wiring follow the wiring diagram as shown.

Connecting the power supply

Rubine RCF WR603 2101 BK Ceiling Fan - Power supply 2 Checkpoint after installation
To ensure safety, kindly check the following.
(a) The ceiling fan is securely fixed to the main hook.
(b) The safety wire is securely fixed and tightened by a screw.
(c) The wiring between the power supply and ceiling fan is connected properly and correctly.
(d) Make sure all the screws to secure the plastic covers are tightened properly.
(e) The screws for securing the fan blades are tightened properly.
(f) The snap pins and nuts provided are inserted and tightened properly.

Our Warranty

3yrs Warranty
FOR FAN MOTOR ONLY
1 yr Warranty
FOR STANDARD PARTS ONLY 1 yr (EXCLUDING ACCESSORIES)
6 mths Warranty Extension
Online Registration

  1. Log on to www.rubine.com.my.
  2. Click on ‘Support’, followed by ‘Product Warranty Regiatration’ to proceed. You’re required to sign up as a member.
  3. You’ll receive a notification of warranty registration confirmation via email.
  4. Please keep your online warranty certificate for reference / future warranty claim.

Customer Care

AFTER-SALES SERVICE:
Tel: 03-6279 8899
Email: [email protected]

OPERATION HOURS:
09:00am – 05:00pm
(Monday – Friday: except public holiday)
This specification is subject to change withour prior notice.
FIAMMA TRADING SDN. BHD. will not be held responsible for the use of supersaded or voided specifications.

rubine.com.my FIAMMA TRADING SDN BHD
330476-P (A member of Fiamma Holdings Berhad)
2-1, Wisma Fiamma, No.20, Jalan 7A/62A,
Bandar Manjalara, 52200 Kuala Lumpur.
Tel: 03-6279 8943

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>