Product Information: Product Name: FRESCO56-5BL Product Name TARSIA48-5BL Product Name: ROTELLO38-5BL Model Numbers: RCF-FRESCO56-5BL, RCF- ROTELLO38-5BL, RCF-TARSIA48-5BL Receiver/Penerima: 12 Power Input: 240VAC/50Hz Power Output: 40W LED Power Output: 24W Product Usage Instructions: Safety Guidelines: 1) Please read through the instruction manual before operating the product to ensure personal safety. 2) Follow the safety guidelines and precautions provided.
Installation
Procedures: Step 1 (Refer to Diagram 1): – Remove the bolt, R-pin, nut,
washer, spring washer, and rubber wheel from the hanging tube coupling plate.
– Place the rubber wheel onto the ceiling U-hook. – Reassemble the bolt,
R-pin, nut, spring washer, and washer in place. – Make sure to insert the
R-pin to prevent the nut from loosening. Step 2 (Refer to Diagrams 2. a, 2. b,
2. c): – Unscrew the safety cable screw. – Remove the hanging tube bracket. –
Remove the safety cable. Step 3 (Refer to Diagram 3): – Unscrew all pre-
assembled blade screws from the fan motor. – Attach the blades to the fan
motor by tightening the screws firmly. – Repeat this step for all blades.
Product Dimension: – RCF-ROTELLO38: A – 185mm, B – 420mm, C – 360mm, D – 980mm
– RCF TARSIA48: A – 185mm, B – 420mm, C – 360mm, D – 1220mm – RCF-FRESCO56: A
– 185mm, B – 420mm, C – 385mm, D – 1420mm RF Transmitter: – The RF transmitter
has various functions controlled by the buttons. – LED Indicator Light:
Indicates the status of the transmitter. – Speed Indicator Light: Indicates
the current speed of the ceiling fan. – Turbo: Activates the highest speed of
the ceiling fan. – Switch off the ceiling fan: Turns off the ceiling fan. –
Increase/Decrease Fan Speed: Adjusts the speed of the ceiling fan. – Turn
up/down the brightness of the LED lamp: Controls the brightness of the LED
lamp. – Turn ON/OFF the LED lamp & Change the LED color: Controls the LED lamp
and changes its color (Warm white, Daylight, Cool white). Please refer to the
diagrams and instructions provided in the user manual for detailed
installation and usage information specific to your product model.
CEILING FAN
WARNING
TO ENSURE YOUR PERSONAL SAFETY, PLEASE READ THROUGH THE INSTRUCTION MANUAL
BEFORE OPERATING THE PRODUCT.
- Do not bend the blade during installation, blade balancing, or fan cleaning.
- To prevent accidents, the power switch must be OFF and electrical wiring must be disconnected before ceiling fan installation, dismantling, maintenance, or cleaning.
- Ceiling fan installation and electrical wiring must be done by qualified technicians in accordance with all applicable codes and air conditioning engineers (ASHRAE) or the local qualified authorities.
- Be cautious when drilling the wall to avoid damaging electrical wiring and other hidden parts.
- The ceiling fan must be hooked to the concrete ceiling. Do not install the ceiling fan on the plaster ceiling or any type of drywall ceiling. During ceiling fan installation, all screws must be tightened at all allocated parts.
SAFETY GUIDELINES
- Please do not install the ceiling fan in high-humidity areas.
- Distance between fan blades and ground must be at least 2.5 meters and above.
- Do not touch the ceiling fan while it is operating.
- For safety purposes, all electrical connections must conform to the national electrical safety codes and earth wire must be installed correctly (suitable for the power supply of 240VAC/50Hz).
- Do not modify the ceiling fan and only use the parts supplied accordingly.
- Do not attempt to repair the fan. Always liaise with our authorized service agent if the fan is not functioning well.
- This appliance is not intended for use by persons (including children) with sensory or mental capabilities, or lack of experience and knowledge unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety.
- Children should be supervised to ensure that they do not play with the appliance.
- The ceiling fan electrical wiring must be installed with means for disconnection incorporated in the fixed wiring provided and a safety cable must be installed according to the steps in this manual.
INSTALLATION PROCEDURES
STEP 1 (Refer to diagram 1)
Remove the bolt, R-pin, nut, at washer, spring washer, and rubber wheel from
the hanging tube. Place the rubber wheel onto the ceiling U-hook and
reassemble the bolt, R-pin, nut, and spring washer, at the washer in place.
IMPORTANT: R-pin MUST be inserted to prevent the nut from loosening
STEP 2 (Refer to diagram 2)
- Unscrew the safety cable screw and washer from the hanging tube coupling plate.
- Tie the safety cable across the U-hook as shown.
- Firmly screw the safety cable with the washer onto the handing tube coupling plate
STEP 3 (Refer to diagram 3)
Unscrew all “pre-assemble blade screws” from the fan motor, and x blade to the
fan motor by tightening the screw firmly. Repeat this step for all blade
STEP 4 (Refer to diagram 4)
Connect wiring by plug-in the connector into position.
STEP 5 (Installation of Light LED)
LANGKAH5 (Pemasangan Lampu LED)
PRODUCT DIMENSION DIAGRAM
RF TRANSMITTER
Front
Function of Transmitter
This fan is operated using the remote control
Note – In the event of Transmitter (Remote Control)/Receiver cannot be
controlled, please follow the “Remote Control Pairing Procedure” as below :
- Insert 2 units of AAA battery into the remote control.
- Switch on the ceiling fan (Power Supply).
- Press the OFF button on the remote control within 30 seconds after powering “Switch On” and hold for about 5 seconds until you hear a “Beep” sound. Pairing completed.
Precaution
- Last Memory Function – this function records the last function mode when power has been disconnected and the fan will maintain the last function used upon power is restored.
- Battery – remove the battery from the transmitter (remote control) when left unused for more than 5 days to prevent battery leaking to damage the transmitter.
- R/F function – to change the direction of rotation (R/F function), the fan needs to come to a complete stop before the reverse function takes effect.
- Only 2 remotes can be paired with a given fan at any time.
IMPORTANT
DO NOT CONNECT THIS CEILING FAN REMOTE CONTROL TO THE DIMMER SWITCH OR WALL
REGULATOR. The ceiling fan must be hooked to the concrete ceiling. Do not
install the ceiling fan on the plaster ceiling or any type of drywall ceiling.
During ceiling fan installation. all screws must be tightened at all allocated
parts
WRONG INSTALLATION
Do not install a ceiling fan under the dome, slanted ceiling, or too high or low distance as it will cause turbulence air flow and inefficient low air performance circulation.
- The ceiling Fan must be mounted above 2.5m from the floor and 1m from the wall to the blade.
- Avoid fixing inside a dome ceiling
- Avoid Installing on a deep tray ceiling
- Avoid Installing on a slanted ceiling.
Our Warranty
Online Registration
- Log on to www.rubine.com.my
- Click on ‘Support’, followed by ‘Product Warranty Registration to proceed. You’re required to sign up as a member.
- You’ll receive a notification of warranty registration confirm- in via email.
- Please keep your online warranty certificate for reference/future warranty claims.
AFTER-SALES SERVICE: Tel: 03-6279 8899
This specification is subject to change without prior notice.
FIAMMA TRADING SDN. BHD. will not be held responsible for the use of
superseded or voided
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>