Rubine RCF-FRESCO56-5B 56 Inch Celling Fan User Manual
- June 12, 2024
- Rubine
Table of Contents
Rubine RCF-FRESCO56-5B 56 Inch Celling Fan
FRESCO56-5B
ROTELLO38-5B
CEILING FAN
SUPPLIED PARTS
WARNING
TO ENSURE YOUR PERSONAL SAFETY, PLEASE READ THROUGH THE INSTRUCTION MANUAL
BEFORE OPERATING THE PRODUCT.
- Do not bend the blade during installation, blades balancing or fan cleaning.
- To prevent accidents, power switch must be OFF and electrical wiring must be disconnected before ceiling fan installation, dismantling, maintenance or cleaning.
- Ceiling fan installation and electrical wiring must be done by quali?ed technician in accordance with all applicable codes and air conditioning engineers (ASHRAE) or the local quali?ed authorities.
- Be cautious when drilling the wall to avoid damaging electrical wiring and other hidden parts.
- Ceiling fan must be hooked on concrete ceiling. Do not install the ceiling fan on plaster ceiling or any types of drywall ceilings. During ceiling fan installation, all screws must be tightened at all allocated parts.
SAFETY GUIDELINES
- Please do not install the ceiling fan at high humidity areas.
- Distance between fan blades and ground must be at least 2.5 meter and above.
- Do not touch the ceiling fan while it is operating.
- For safety purposes, all electrical connections must conform to the national electrical safety codes and earth wire must be installed correctly (suitable for power supply of 240VAC/50Hz).
- Do not modify the ceiling fan and only use the parts supplied accordingly.
- Do not attempt to repair the fan. Always liaise to our authorized service agent if the fan is not functioning well.
- This appliance is not intended for use by persons (including children) with lack of sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
- Children should be supervised to ensure that they do not play with the appliance.
- The ceiling fan electrical wiring must be installed with means for disconnection incorporated in the ?xed wiring provided and safety cable must be installed according to the steps in this manual.
INSTALLATION PROCEDURES
STEP 1 (Refer diagram 1)
Remove the bolt, R-pin, nut, flat washer, spring washer and rubber wheel from
the hanging tube coupling plate . Place the rubber wheel onto the ceiling
U-hook and reassemble the bolt, R-pin, nut, spring washer, and flat washer in
place.
IMPORTANT: R-pin MUST be inserted to prevent nut from loosening
STEP 2 (Refer diagram 2)
- Unscrew the safety cable screw and washer from the hanging tube coupling plate.
- Tie the safety cable across the U-hook as shown.
- Firmly screw the safety cable with washer onto the handing tube coupling plate
STEP 3 (Refer diagram 3)
Unscrew all “pre-assemble blade screw” from fan motor, and fix blade to fan
motor by tighten the screw firmly. Repeat this step for all blades.
STEP 4 (Refer to diagram 4)
Connect wiring by plug-in connector into
STEP 5 (Installation of decorative cover)
Hold the bottom cover up, install it on the motor assembly, and rotate it
clockwise until the bottom cover is astened.
PRODUCT DIMENSION DIAGRAM
RF TRANSMITTER
Function of Transmitter
Front
- Battery cover 2 X 1.5V battery (AAA)
Back
This fan is operated using remote control.
Note – In the event of Transmitter (Remote Control)/Receiver cannot be control, please follow the “Remote Control Pairing Procedure” as below :
- Insert 2 units of AAA battery into the remote control.
- Switch on the ceiling fan (Power Supply).
- Press the OFF button on the remote control within 30 seconds after power “Switch On” and hold for about 5 seconds until you hear a “Beep” sound. Pairing completed.
IMPORTANT
The ceiling fan must be hooked to the concrete ceiling. Do not install the ceiling fan on the plaster ceiling or any type of all ceilings. During ceiling fan installation, all screws must be tightened at all allocated parts.
WRONG INSTALLATION
Do not install ceiling fan under dome, slanted ceiling, too high or low distance as it will cause turbulence air flow and ineffcient low air performance circulation.
- The ceiling Fan must be mounted above 2.5m from the floor 1m from the wall to the blade.
- Avoid fixing inside a dome ceiling.
- Avoid Installing on a deep tray ceiling.
- Avoid Installing on a slanted ceiling.
Warranty
6mths Warranty Extension
- Online Registration Log on to www.rubine.com.my
- Click on ‘Support’, followed by ‘Product Warranty Registration’ to proceed. You’re required to sign up as a member.
- You’ll receive a notification of warranty registration confirma- tion via email.
- Please keep your online warranty certificate for reference/future warranty claim.
Customer Care
AFTER-SALES SERVICE:
- Tel : 03-6279 8899
- Email: ftcrm@fiamma.com.my
OPERATION HOURS:
- 09:OOam – 05:OOpm
- (Monday Friday, except publ c holiday)
This specification is subject to change without prior notice FAMMA TRADING SDN. BHD. will not be he d responsible for the use of superseded or voided specifications
- rubine.com.my
- FIAMMA TRADING SDN BHD (A Holdings Berhad)
- 2-1, Wisma Fiamma, No.20, Jalan 7A/62A, Bandar Manjalara, 52200 Kuala Lumpur. Tel: 03-6279 8943
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>