Rubine CE521D Water Heater User Manual

June 13, 2024
Rubine

Rubine CE521D Water Heater User Manual
Rubine CE521D Water Heater

Please read this manual thoroughly and understand the content before use.

_ **

Warring Icon**_ SAFETY PRECAUTION

  1. Do not install reverse INLET & OUTLET and Stop Valve of heater.

  2. Do not install the heater where there is consistent spray directly over the unit.

  3. Do not connect the OUTLET to any tap or fitting that is not recommended by the
    manufacturer.

  4. Do not block the heater OUTLET in any way.

  5. Do not attempt to repair the heater without qualified technician.

  6. This appliance is not intended for use by person (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been supervision or instruction concerning use of the appliance by a person responsible for their safety.

  7. Children should be supervised to ensure that they do not play with the appliance.

  8. Engage qualified electrician for installation.

  9. Test water temperature with hand before using the shower.

  10. Check the RCCB once a month (please refer to the Test Run of Heater) and consult professional for repair if there is any malfunction.

  11. Metallic / chrome flexible hose and conductive control valve shall not be used.

  12. Use only new hoses to connect the appliance to the water supply. The old hose-sets should not be reused.

  13. This appliance is not to be used for portable water supply.

  14. Do not leave the hand shower idle in the pail. (refer below)

Water Heater

WATER HEATER PARTS IDENTIFICATION

EXTERNAL PARTS IDENTIFICATION
EXTERNAL PARTS IDENTIFICATION
INTERNAL PARTS IDENTIFICATION
PARTS IDENTIFICATION

SHOWER SET ACCESSORIES IDENTIFICATION

BLACK ACCESSORIES

  1. BLACK ACCESSORIES
  2. BLACK ACCESSORIES
  3. BLACK ACCESSORIES

BLACK ACCESSORIES

RAIN SHOWER SET – 3 IN 1 DIVERTER
(For selected model only)

RAIN SHOWER SET
RAIN SHOWER SET
DIVERTER

MULTIPLE USAGE OF FAUCET

3-in-1 Diverter

  1. Easy access of warm and normal temperature water outlet
    USAGE OF FAUCET

  2. Warm water for

  3. Warm shower for hand wash clothes baby bathtub For selected models only

  4. Warm shower for your pet made easy with faucet instead of handheld hand shower head.

GENERAL INFORMATION

INSTALLATION
_ Warring IconCAUTION:
_ THIS APPLIANCE MUST BE EARTHED

  1. All the plumbing work should be completed before proceeding to electrical wiring connection. (Table 1)
  2. installation must be carried out by qualified electrician with close reference to this manual and in compliance with the local regulations.
  3. The unit works at minimum water flow rate of 2 liter/min, which then would trigger the built-in pump (only for pump model), bolstering a stronger shower spray.
  4. The built-in electronic Residual Current Circuit Breaker (RCCB) would cut-off the power supply to heater in the event of current leakage of as low as 15mA.
  5. The Thermal Cut-Off would automatically shut off the power supply shall there is any abnormal rise of showering temperature.
  6. The unit only operates when there is sufficient water flow to trigger the flow switch.
  7. Electrical loading Table 1:
    Voltage(Vac)| Power (kW)| Amperes (A)| Recommended Conductor Size (csa)| Fuse/ MCB(A)| ON/OFF Switch (A)
    ---|---|---|---|---|---
    mm2| Conduit Cable| flexible Cable
    220 – 50/60Hz| 3.5| 16.0| 2.5| 7/0.67mm| 50/0.25| 20| 20
    4.5| 20.5| 2.5| 7/0.67mm| 56/0.30| 25| 25
    5.5| 25.0| 4.0| 7/0.85mm| 56/0.30| 32| 32
    6.0| 27.3| 4.0| 7/0.85mm| 56/0.30| 32| 32
    6.5| 29.6| 4.0|  7/0.85mm| 84/0.30| 32| 32
    7.5| 34.1| 6.0| 7/1.04mm| 84/0.30| 40| 40
    8.0| 36.4| 6.0| 7/1.04mm| 84/0.30| 40| 40
    230 – 50/60Hz| 3.5| 15.2| 2.5| 7/0.67mm| 50/0.25| 20| 20
    5.5| 24.0| 4.0| 7/0.85mm| 56/0.30| 32| 32
    6.6| 28.7| 4.0| 7/0.85mm| 56/0.30| 32| 32
    8.8| 28.3| 6.0| 7/1.04mm| 84/0.30| 40| 40
    240 – 50/60Hz| 3.6| 15.0| 4.0| 7/0.85mm| 56/0.30| 32| 32
    3.8| 15.8| 4.0| 7/0.85mm| 56/0.30| 32| 32
    4.25| 17.5| 4.0| 7/0.85mm| 56/0.30| 32| 32
    7.7| 32.1| 6.0| 7/1.04mm| 84/0.30| 40| 40
    9.0| 37.5| 6.0| 7/1.04mm| 84/0.30| 40| 40
  8. Instantaneous water heater shall be equipped with a 2-pole control switch and own residual current device.
  9. Water heaters exceeding 3kW shall be permanently connected to a 20A/30A rated circuit breaker/fuse with an isolator switch and residual current device.

INSTALLATION PROCEDURES

  1. INLET and OUTLET connection of the heater unit should not be reversed, with stop valve installed on INLET. (Diagram 1)
    Diagram
    Diagram 1

  2. It is recommended that the unit should be mounted above 1.5m above the floor to bottom of the heater. (Diagram 1)

  3. Mounting position
    Lift upward
    Lift upward
    Diagram 2

    • Remove screw at the bottom of the heater

    • Lift the plastic cover upward (Refer Diagram 2)
      Refer Diagram
      Diagram 3
      WARNING !

      To prevent vibration, all 4 screw must be tightened fully.

    • Mark mounting position on the wall for all 4 screws

    • Drill the holes with 5.0mm diameter drill bit (Refer Diagram 3

    • Install the unit to the wall with plug

  4. Installation of Heater INLET and OUTLET connection. 
    Installation of Heater
    outlet reverse
    inlet – outlet reverse (wrong installation)
    stop valve reverse
    stop valve reverse (wrong installation)
    WARNING !
    Wrong installation will caused damage to heating element.

  5. Electrical Connection.

IMPORTANT NOTE ! NOTA PENTING !

SWITCH OFF THE MAIN SUPPLY BEFORE ELECTRICAL WORK.
a) Insert electrical cable through the rubber grommet as (Diagram 5).
b) Connect the cable to the terminal block and fully tighten as below :

Ensure all wiring connection is completely
TIGHTEN!
Electrical cable
Diagram 5
Electrical cable (Recommended conductor size 4.0mm2 )

To install cover:

  1. Place top part into position & fit in nicely.
  2. Press firmly the bottom part until “click” to secure the cover.
  3. Install screw at bottom to lock in position.

Diagram
Diagram 6

OPERATION PROCEDURES / TEST RUN OF HEATER

  1. Turn on stop valve (anti – clockwise)
    Stop Valve knob position during off
    Stop Valve knob position during off

  2. Make sure water flow starts after stop valve had been turned on.
    Make sure

  3. Switch on the main power supply and green “POWER” LED would light up.
    Switch on the main power supply

  4. Turn on temperature control knob and red “HEATER” LED would light up.
    Temperature
    Temperature control knob during off

  5. Test the ELCB by pressing “TEST” button. The unit should be tripped. “POWER” LED light and “HEATER” LED light would turn off
    “RESET” button
    “RESET” button

  6. Press reset button to resume power connection.
    “RESET” button
    “RESET” button

  7. The heater is now ready for use. Temperature will be increased accordingly as the knob being turned clockwise from “ON” to “MAX”
    heater is now ready f

  8. Turn the pressure control knob “ Inverter Silent Pump” (only for pump model) clockwise from “ON” to “MAX” for bolstering a stronger shower spray.
    pressure control

  9. Switch off the heater and main power supply when not in use.
    Temperature

GENERAL MAINTENANCE

damp cloth
Filter Mesh
Filter Mesh

Warring IconCLEAN FILTER MESH REGULARLY

TECHNICAL SPECIFICATIONS

Electrical loading / Muatan elektrik 4.25kW 240V 50/60Hz
Other loading / Muatan lain Please refer Electrial loading table _Rujuk

jadual pendawaian elektrik_
RCCB sensitivity / Sensitiviti RCCB| 15 mA
Operating condition / Keadaan berfungsi| Open system (Open outlet) / Sistem terbuka
Water connection / Sambungan air| 15mm (1/2” BSP)
Degree of protection / T ahap perlindungan| IP25
Min water flow rate / Kadar aliran air min| 2 litre/ min
Min water pressure / Tekanan air min| 20kPa ( 0.2 bar / 2.9psi )
Max water pressure / Tekanan air max| 4 bar ( 400kPa / 58psi )
Heater dimension (mm) / Ukuran pemanas| 440 (H) x 205 (W) x 87 (D)
Heater nett weight / Berat bersih pemanas| Non pump / Tanpa pam : 1.3kg Inverter Silent DC Pump / Pam Senyap Inverter DC : 1.8kg

SCHEMATIC WIRING DIAGRAM

INVERTER SILENT DC PUMP (CE521D) PAM SENYAP INVERTER DC
WIRING DIAGRAM
NON-PUMP (CE520N) TANPA PAM
WIRING DIAGRAM

Our Warranty

  • on Internal Parts
    Our Warranty

  • on Inverter DC Silent Pump
    Our Warranty

  • on Heating Element
    Our Warranty

  • on Anti-tank Leakage
    Our Warranty

6 moths Warranty Extension

  1. Online Registration
  2. Log on to www.rubine.com.my
  3. Click on ‘Support’, followed by ‘Product Warranty Registration’to proceed. You’re required to sign up as a member.
  4. You’ll receive a notification of warranty registration confirmation via email.
  5. Please keep your online warranty certificate for reference / future warranty claim

Customer Care

This specification is subject to change without prior notice,
FIAMMA TRADING SDN. BHD. will not be held responsible for the use of superseded or voided specification.

rubine.com.my
FIAMMA TRADING SDN BHD 330476-P (A member of Fiamma Holdings Berhad) 2-1, Wisma Fiamma, No.20, Jalan 7A/62A, Bandar Manjalara, 52200 Kuala Lumpur. Tel: 03-6279 8943

AFTER – SALES SERVICE:
Tel : 03-6279 8899
Email : ftcrm@fiamma.com.my
OPERATION HOURS:
Tel : 09:00am – 05:00pm
(Monday – Friday, except public holiday)
Rubine Logo

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>