Rubine RCF-Mozia56-5B Ceiling Fan User Manual

June 13, 2024
Rubine

Rubine LOGO

REDEFINE THE WAY OF LIFE
RCF-MOZIA56 SERIES
User Manual

Rubine RCF Mozia56 5B Ceiling Fan -

RCF-MOZIA56 SERIES
USER MANUAL
MODEL RCF-Mozia56-5B / RCF-Mozia56-5BLiLight model)

NO PARTS QUANTITY NO SCREW PACK QUANTITY
1 TOP CANOPY / x 1 7 BALANCING KIT / x 1 set
2 HANGING TUBE / x 1 8 TRANSMITTER/ x 1
3 COUPLING COVER / x 1 9 RECEIVER x 1
4 FAN MOTOR x 1 10 BLADE SCREWS /
FLAT WASHER / x 11
5 FAN BLADES x 5
6 BOTTOM COVER x 1 11 WIRE NUT / x3

Rubine RCF BREEZA Series Ceiling Fan - Fig

FAN SIZE| VOLTAGE| MAX FAN POWER| MAX LIGHT POWER| MAX SPEED(RPM)| NETT WEIGHT| GROSS WEIGHT
---|---|---|---|---|---|---
56″| 240V/50Hz| 36W| N/A| 203±10%| 4.8Kg| 5.8Kg

WARNING
TO ENSURE YOUR PERSONAL SAFETY, PLEASE READ THROUGH THE INSTRUCTION
MANUAL BEFORE OPERATING THE PRODUCT.

  1. 1. Do not bend the blade during installation, blades balancing or fan cleaning.
  2. To prevent accidents, power switch must be OFF and electrical wiring must be disconnected before ceiling fan installation, dismantling, maintenance or cleaning.
  3. Ceiling fan installation and electrical wiring must be done by qualified technician in accordance with all applicable codes and air conditioning engineers (ASHRAE) or the local qualified authorities.
  4. Be cautious when drilling the wall to ovoid damaging electrical wiring and other hidden ports.
  5. Ceiling fan must be hooked on concrete ceiling. Do not install the ceiling fan on plaster ceiling or any types of drywall ceilings. During ceiling fan installation, all screws must be tightened at all allocated ports.

SAFETY GUIDELINES

  1. 1. Please do not install the ceiling fan at high humidity areas.
  2. Distance between fan blades and ground must be at least 2.5 meter and above.

  3. Do not touch the ceiling fan while it is operating.

  4. For safety purposes, all electrical connections must conform to the national electrical safety codes and earth wire must be installed correctly (suitable for power supply of 240VAC/50Hz).

  5. Do not modify the ceiling fan and only use the parts supplied accordingly.

  6. Do not attempt to repair the fan. Always liaise to our authorized service agent if the fan is not functioning well.

  7. This appliance is not intended for use by persons (including children) with lack of sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.

  8.  Children should be supervised to ensure that they do not play with the appliance.

  9. The ceiling fan electrical wiring must be installed with means for disconnection incorporated in the fixed wiring provided and safety cable must be installed according to the steps in this manual.

NSTALLATION PROCEDURES

STEP 1 (See Diagram 1)

  1. 1. Before installation, remove the rubber wheel from both side of the hanging tube.  

    Rubine RCF BREEZA Series Ceiling Fan - Fig1

STEP 2 (See Diagram 2)

  1. 1. Insert the hanging tube through top canopy and coupling cover.
  2.  Thread the safety cable and lead wire from the fan motor though the hanging tube. Place the lead wire and safety cable out the top of hanging tube.
  3. Insert the hanging tube into the motor and aligning holes to the motor coupling.
  4. Screw the hanging tube to motor with the previous bolt, washer, nut and R-pin.

DIAGRAM 2

INSTALLATION PROCEDURES

Step 3 (See Diagram )

  1. 1. Remove the bolt at the rubber wheel before installation.
  2. Hang the rubber wheel on the U-Hook. (Figure a)

Rubine RCF BREEZA Series Ceiling Fan - angkah

Step 4 (See Diagram )

  1. Lift the motor until the bracket hole of the hanging tube and rubber wheel’s hole are aligned.
  2. Use bolts to pass through the hanging tube coupling plat and the rubber wheel and tighten the bolts, flat washer, spring washer, nut, R-pin that were loosened previously.

Rubine RCF BREEZA Series Ceiling Fan - angkah1

Step 5 (Safety Cable Installation)

  1. Remove the safety cable screw from the hanging tube coupling plat. (Diagram 1)
  2. Arrange the safety cable as above diagram 2 shown.
  3. Tighten the safety cable on the hanging tube with screws, (Diagram 3)

Rubine RCF BREEZA Series Ceiling Fan - Langkah

WARNING If the safety cable is not properly secured, it may cause injury if the ceiling fan falls.

STEP 6 (Electrical Wiring Connection)

caution. Risk of electric shock

  1. 1. Turn off the power supply before installing the ceiling fan.
  2. Use the two pieces of “lead wire connector” from the screw pack and connect them to the fan motor’s wire socket and then connect all 3 wires “live, Neutral & Earth” to incoming power supply accordingly.
  3. Installation should be performed by a qualified electrician, and all wiring connections must be in accordance with local national regulatory wire standards.Rubine RCF BREEZA Series Ceiling Fan - Langkah 1

STEP 7 (Refer Diagram )

  1. Raise the top canopy and tighten it with the screw attached.

STEP 8 (Blade Installation)

  1. 1. Insert the blade screws through the flat washed blade then secure the blade to the motor by tightening the screws.  

    Rubine RCF Mozia56 5B Ceiling Fan - fig4

  2. Repeat this process to install all the other blades.

STEP 9 (Refer Diagram )

  1. Install the bottom cover to the fan by turning it clockwise.

Rubine RCF Mozia56 5B Ceiling Fan - fig5
Rubine RCF Mozia56 5B Ceiling Fan - fig6

PRODUCT DIMENSION DIAGRAM

Rubine RCF Mozia56 5B Ceiling Fan - fig7

Transmitter

Installation:

  1. 1. Install the RF Transmitter holder on wall with the 2 screws provided.
  2. Install provided battery into the RF Transmitter.
    Note:

  3. RF Transmitter pack included 2 pieces of 1.5V (AAA) battery.

  4. For non lighting ceiling fan model, the light button has no function.

  5. All RF transmitter had been pre-paired during production from factory. Please follow the RF paring procedure as below if the ceiling fan could not operate.

Rubine RCF BREEZA Series Ceiling Fan - PRODUCT1

Auto reduce and maintain at speed
See.mode:
2 after 1 hour from initial speed.

  1. 1. Speed 1
  2. Speed 2
  3. Speed 3
  4. .Speed 4
  5. Speed 5
  6. Speed 6
  7. Speed 7
  8. TURBO Speed
  9. Switch OFF the Fan

R/F Reverse or Forward (the spin direction of ceiling fan)
 LED Light Function LED color will change on each time a press the “lighting button” in sequence: Warm Light > Day Light > Cool Light > OFF and repeat again.

RF Transmitter/ Receiver pairing procedure
Learning function:
Installation :

  1. 1. Insert 2 units of AAA battery into the remote control.
  2. Switch on the ceiling fan (Power Supply).
  3. Press the OFF button on the remote control with in 3 seconds after power “Switch On” and hold for about 5 seconds unti you hear a sound. Pairing completed.
  4. If paring more than 1 unit (Same RF DC Motor): Switch power on for the first unit and others power must be switch OFF, and then pair ceiling fan to follow the above step 1, step 2 and step 3. Repeat the same for second units and others.

 In order to reduce damage to the RF transmitter , if you don’t use for a long me, please take out the battery.

TROUBLE SHOOTING

Symptom Possible Solution
Wobbles • Ensure that all screws securing the fan blades are tightened.

• Ensure all fan blades are aligned.
• If you have multiple ceiling fans installed, make sure they are not less than 2 meters away.
• If the fan blade is damaged, contact the after sales service center for replacement. If the damage does not originate from the manufacturer, a fee will be charged.
Noisy| • Check all installations. If it is loose, tighten it.
Jerks upon startup| • This is a normal phenomenon, as the power is passed through a three-phase brushless DC motor without affecting performance.
No airflow| • Make sure it is not turning in the “reverse” direction
Fan not functioning| • Make sure all wires are connected correctly.
• If the voltage is lower than 140V or exceeds 270V for more than 5 seconds, the motor will automatically cut off the power supply. When the voltage
returns to normal, it will turn on automatically.
Remote control not functioning| • When the remote control button is pressed, the LED indicator flashes, indicating that the battery voltage is too low, please replace the battery with a new one.
During high speed, the don turning fast  and then slow down| • This is normal as the motor is not only protected by a voltage regulator, it is also protected by an additional thermal sensor where it will limit the  motor temperature from rising to not more than 75°C. It is to increase the life span of the motor.

IMPORTANT

DO NOT CONNECT THIS CEILING FAN REMOTE CONTROL TO DIMMER SWITCH OR WALL REGULATOR.

Ceiling fan must be hooked on concrete ceiling. Do not install the ceiling fan on plaster ceiling or any types of drywall ceilings. During ceiling fan installation, all screws must be tightened at all allocated parts.

XWRONG INSTALLATION

Do not install ceiling fan under dome, slanted ceiling, too high or low distance as it will cause turbulence air flow and inefficient low air performance circulation.
a) Ceiling Fan must be mounted above 2.5m from the floor 1 m from the wall to the blade.

b) Avoid fixing inside a dome ceiling.

c)Avoid Installing on a deep tray ceiling.

d)Avoid Installing on a slanted ceiling.

Our Warranty

10,yrs
Warranty FOR FAN MOTOR ONLY
2,yrs
Warranty  FOR RECEIVER ONLY
1yr
Warranty FOR ALL PARTS (EXCLUDING ACCESSORIES)

6 mths Warranty Extension

Online Registration

  1. 1. Log on to [www.rubine.com.my](http://www.rubine.com.my/)
  2. Click on ‘Support’, followed by ‘Product Warranty Registration’ to proceed. You’re required to sign up as a member.
  3. You’ll receive a notification of warranty registration confirma­tion via email.Please keep your on line warranty certificate for reference/future warranty claim.

Customer Care

AFTER-SALES SERVICE: OPERATION HOURS:

Tel : 03-6279 8899
Email: ftcrm@fiamma.com.my| 09:00am – 05:00pm
(Monday -Friday, except public holiday)

This specification is subject to change without prior notice.
FIAMMA TRADING SDN. BHD, will not be held responsible for the use of superseded or voided specifications.
rubine.com.my
 FIAMMA TRADING SDN BH D 330476-P (A member of Fiamma Holdings Berthed)
2-1, Wisma Fiamma, No.20, Jalan 7A/62A, Bandar Mangalore, 52200 Kuala Lumpur. Tel: 03-6279 8943
Rubine LOGO

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals