HEAT GLO 6K-8K Modern Direct Vent Gas Fireplace Instructions
- June 13, 2024
- HEAT GLO
Table of Contents
HEAT GLO 6K-8K Modern Direct Vent Gas Fireplace
Product Information
Product Name: 6K MODERN Direct Vent Gas Fireplace
Specifications:
- Front Width: 41 inches [1041 mm]
- Height: 40-7/8 inches [1038 mm]
- Depth: 21-7/16 inches [545 mm]
- Glass Size: 24-3/4 x 34-1/4 inches [629 x 870 mm]
- BTU/Hour Input: 17,000 – 34,000 BTUs (NG)
- Weight: 169 lbs [77 kgs]
Product Usage Instructions
Basic Corner Installation:
Adjust framing dimensions for interior chase sheathing (such as sheetrock).
Reference the installation manual for additional venting scenarios.
Combustible Mantel Projections:
Note: All measurements in inches.
- To Ceiling: 18 inches
- Measurement from fireplace opening to bottom of appliance: 33-1/2 inches
Non-Combustible Mantel Projections:
Note: All measurements in inches.
- To Ceiling: 18 inches
- Measurement from fireplace opening to bottom of appliance: 33-1/2 inches
Exterior Chase Minimum Height Requirements:
- Wall Penetration: Do not pack vent framing hole with insulation or other material.
- A minimum: 3 inches
- B*: 48-3/4 inches [1238 mm]
-
- Shows center of vent framing hole for top or rear venting.
- The center of the hole is one (1) inch (25 mm) above the center of the horizontal vent pipe.
- Required minimum off top: 6 inches
- Note: If overhang (A) is less than 2 inches, clearance from top of termination cap to bottom of overhang (B) may be 0 inches.
Additional Information:
If using heat management, please refer to the fireplace installation manual
for framing guidelines and reduced mantel clearances. Additional information
on venting, TV clearances, finishing requirements, fronts, etc., can be found
in the installation and owner’s manual.
ACTUAL DIMENSIONS
| FRONT WIDTH| HEIGHT| DEPTH| GLASS SIZE| BTU/HOUR
INPUT
---|---|---|---|---|---
41″ [1041]| 40-7/8″ [1038]| 21-7/16″ [545]| 24-3/4″ x 34-1/4″ [629 X 870]|
17,000 – 34,000 BTUs (NG)
TOP VIEW
FRAMING DIMENSIONS
| FRONT WIDTH| HEIGHT| DEPTH| WEIGHT
42″ [1067]| 40-1/8″ [1019]| 22″ [559]| 169 LBS [77 KGS]
COMBUSTIBLE MANTEL PROJECTIONS
Note: Measurement is taken from top of the opening,
Portrait front requires taller combustible clearances or Passive Heat; see
install manual for details.
NON-COMBUSTIBLE MANTEL PROJECTIONS Note: Measurement is taken from top of the opening, not the top of fireplace.
COMBUSTIBLE MANTEL LEGS OR WALL PROJECTIONS
NON-COMBUSTIBLE MANTEL LEGS OR WALL PROJECTIONS
If using heat management please refer to the fireplace installation manual for framing guidelines and reduced mantel clearances. Additional information on venting, TV clearances, finishing requirements, fronts, etc can be found in the installation and owner’s manual
EXTERIOR CHASE MINIMUM HEIGHT REQUIREMENTS
-
NOTE: If overhang (A) is less than 2 inches, clearance from top of termination cap to bottom of overhang (B) may be 0 inches.
- Measured from back of vent cap to end of overhang
- Measured from bottom of overhang to top of termination cap
Vinyl Siding Shield (TRAP-VSS) Information
TRAP-VSS required if overhang (A) is greater than 3 inches but less than 5
inches and B dimension is less than 18 inches.
WALL PENETRATION
DO NOT PACK VENT FRAMING HOLE WITH INSULATION OR OTHER MATERIAL.
- Shows center of vent framing hole for top or rear venting. The center of the hole is one (1) in. (25 mm) above the center of the horizontal vent pipe.
PRODUCT LISTING CODES
US| ANSI Z21.88-2019
CAN| CSA 2.33-2019
| UL307B
Product information provided is not complete and is subject to change without notice. Product installation must adhere strictly to instructions accompanying product to avoid risk of fire and potential injury.
Heat & Glo — A Brand of Hearth & Home Technologies 7571 215th Street West |
Lakeville, MN 55044
877-486-9123 |