HEAT GLO PRIMO-II-60 Series Gas Fireplace Instruction Manual

June 12, 2024
HEAT GLO

PRIMO ll 60
Direct Vent Gas Fireplace

PRIMO-II-60 Series Gas Fireplace

Scan QR code for installation manual for final dimensions and requirements.

https://qrcodes.pro/F94XRb

FRONT WIDTH HEIGHT DEPTH GLASS SIZE BTU/HOUR INPUT
ACTUAL DIMENSIONS 76-3/8″ [1940] 40-13/16″ [1037] 18-1/4″ [464] 60″ x 18″
[1524 X 457] 39,500 – 57,000 BTUs (NG)

36,500 – 50,000 BTUs (LP)

HEAT GLO PRIMO II 60 Series Gas Fireplace -

FRONT WIDTH HEIGHT DEPTH WEIGHT
FRAMING DIMENSIONS 78-3/4″ [2000) 45″ [1143) 18″ (457]

Adjust framing dimensions for interior chase sheathing (such as 1/2″ drywall)
Header depth not to exceed 5-1/2″.
If header depth is greater than 3-1/2″, header must be notched in order to maintain clearance to pipe.
If appliance is installed off of floor, maintain required clearances to combustibles. Construct platform in accordance to local building codes.
BASIC CORNER INSTALLATION

HEAT GLO PRIMO II 60 Series Gas Fireplace - fig2

Reference install manual for additional venting scenarios

Specifications

COMBUSTIBLE OR NON-COMBUSTIBLE MANTELS

HEAT GLO PRIMO II 60 Series Gas Fireplace - fig3

COMBUSTIBLE OR NON-COMBUSTIBLE MANTEL LEGS OR WALL PROJECTIONS

EXTERIOR CHASE MINIMUM HEIGHT REQUIREMENTS

HEAT GLO PRIMO II 60 Series Gas Fireplace - fig5

WALL PENETRATION

DO NOT PACK VENT FRAMING HOLE WITH INSULATION OR OTHER MATERIAL.

HEAT GLO PRIMO II 60 Series Gas Fireplace - fig6

  • Shows center of vent framing hole for top venting. The center of the hole is one 1″ (25mm) above the center of the horizontal vent pipe.
    Note: Center of the horizontal vent pipe to the vertical measuring surface of a trap cap is 5″ (127mm).

PRODUCT LISTING CODES

US| ANSI Z21.50-2019
CAN| CSA 2.22-2019

Product information provided is not complete and is subject to change without notice. Product installation must adhere strictly to instructions accompanying product to avoid risk of fire and potential injury.

Heat & Glo — A Brand of Hearth & Home Technologies
7571 215th Street West | Lakeville, MN 55044
877-486-9123 | heatnglo.com