HEAT GLO 8KL Direct Vent Gas Fireplace Installation Guide
- June 12, 2024
- HEAT GLO
Table of Contents
8KL
Direct Vent Gas Fireplace
8KL Direct Vent Gas Fireplace
Scan QR code for installation manual for final dimensions and requirements.
ACTUAL
DIMENSIONS| FRONT WIDTH| HEIGHT| DEPTH| GLASS SIZE|
BTU/HOUR INPUT
---|---|---|---|---|---
48-1/16″ [1221]| 42-7/8″ [1089]| 21-7/16″ [545]| 41-1/4″ x 26-11/16″
[1048 X 678]| 20,000 – 40,000 BTUs (NG)
22,000 – 40,000 BTUs (LP)
FRAMING
DIMENSIONS| FRONT WIDTH| HEIGHT| DEPTH| WEIGHT
---|---|---|---|---
49″ [1245]| 42-1/8″ [1070]| 22″ [559]| 217 LBS [98 KGS]
Specifications
COMBUSTIBLE MANTEL PROJECTIONS
Note: Measurement is taken from top of the opening, NOT the top of the
fireplace.
Portrait front requires taller combustible clearances or Passive Heat; see
install manual for details.
NON-COMBUSTIBLE MANTEL PROJECTIONS
Note: All measurements inches
Note: Measurement is taken from top of the opening, NOT the top of the fireplace.
COMBUSTIBLE MANTEL LEGS OR WALL PROJECTIONS
Combustible Mantel Leg or Wall Projections (Acceptable on both sides of opening)
NON-COMBUSTIBLE MANTEL LEGS OR WALL PROJECTIONS
Non-Combustible Mantel Leg or Wall Projections (Acceptable on both sides of
opening)
If using heat management please refer to the fireplace installation manual for
framing guidelines and reduced mantel clearances. Additional information on
venting, TV clearances, finishing requirements, fronts, etc can be found in
the installation and owner’s manual
EXTERIOR CHASE MINIMUM HEIGHT REQUIREMENTS
- NOTE: If overhang (A) is less than 2 inches, clearance from top of termination cap to bottom of overhang (B) may be 0 inches.
A – Measured from back of vent cap to end of overhang
B – Measured from bottom of overhang to top of termination cap Vinyl Siding Shield (TRAP-VSS) Information
TRAP-VSS required if overhang (A) is greater than 3 inches but less than 5 inches and B dimension is less than 18 inches.
TRAP-VSS recommended if either of the below is true:
– Overhang (A) is less than 5 inches (to combat water infiltration)
– A vinyl overhang is present
WALL PENETRATION
DO NOT PACK VENT FRAMING HOLE WITH INSULATION OR OTHER MATERIAL.
- Shows center of vent framing hole for top or rear venting. The center of the hole is one (1) in. (25 mm) above the center of the horizontal vent pipe.
PRODUCT LISTING CODES
US| ANSI Z21.88-2019
CAN| CSA 2.33-2019
| UL30713